High Precision Quantitative Proteomics Using iTRAQ on an LTQ Orbitrap: A New Mass Spectrometric Method Combining the Benefits of All
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The development of quantitative techniques in mass spectrometry has generated the ability to systematically monitor protein expression. Isobaric tags for relative and absolute quantification (iTRAQ) have become a widely used tool for the quantification of proteins. However, application of iTRAQ methodology using ion traps and hybrid mass spectrometers containing an ion trap such as the LTQ-Orbitrap was not possible until the development of pulsed Q dissociation (PQD) and higher energy C-trap dissociation (HCD). Both methods allow iTRAQ-based quantification on an LTQ-Orbitrap but are less suited for protein identification at a proteomic scale than the commonly used collisional induced dissociation (CID) fragmentation. We developed an analytical strategy combining the advantages of CID and HCD, allowing sensitive and accurate protein identification and quantitation at the same time. In a direct comparison, the novel method outperformed PQD and HCD regarding its limit of detection, the number of identified peptides and the analytical precision of quantitation. The new method was applied to study changes in protein expression in mouse hearts upon transverse aortic constriction, a model for cardiac stress.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
Ross, P. L., Huang, Y. N., Marchese, J. N., Williamson, B., Parker, K., Hattan, S., Khainovski, N., Pillai, S., Dey, S., Daniels, S., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400129-mcp200 · Cited by 4,401
Absolute quantification of proteins and phosphoproteins from cell lysates by tandem MS
Gerber, S. A., Rush, J., Stemman, O., Kirschner, M. W., & Gygi, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832254100 · Cited by 1,733
Mass spectrometry–based proteomics turns quantitative
Ong, S.-E., & Mann, M. (2005) · Nature Chemical Biology · doi:10.1038/nchembio736 · Cited by 1,572
Systems Biology and New Technologies Enable Predictive and Preventative Medicine
Hood, L., Heath, J. R., Phelps, M. E., & Lin, B. (2004) · Science · doi:10.1126/science.1104635 · Cited by 1,108
Interpretation of Shotgun Proteomic Data
Nesvizhskii, A. I., & Aebersold, R. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r500012-mcp200 · Cited by 1,025
Functional and quantitative proteomics using SILAC
Mann, M. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2067 · Cited by 931
On the Proper Use of Mass Accuracy in Proteomics
Zubarev, R., & Mann, M. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m600380-mcp200 · Cited by 165
I-DIRT, A General Method for Distinguishing between Specific and Nonspecific Protein Interactions
Tackett, A. J., DeGrasse, J. A., Sekedat, M. D., Oeffinger, M., Rout, M. P., & Chait, B. T. (2005) · Journal of Proteome Research · doi:10.1021/pr050225e · Cited by 131
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Chemoproteomics profiling of HDAC inhibitors reveals selective targeting of HDAC complexes
Bantscheff, M., Hopf, C., Savitski, M. M., Dittmann, A., Grandi, P., Michon, A.-M., Schlegl, J., Abraham, Y., Becher, I., Bergamini, G., et al. (2011) · Nature Biotechnology · doi:10.1038/nbt.1759 · Cited by 659
Isobaric Labeling-Based Relative Quantification in Shotgun Proteomics
Rauniyar, N., & Yates, J. R. (2014) · Journal of Proteome Research · doi:10.1021/pr500880b · Cited by 596
Proteome Discoverer—A Community Enhanced Data Processing Suite for Protein Informatics
Orsburn, B. C. (2021) · Proteomes · doi:10.3390/proteomes9010015 · Cited by 336
Frese, C. K., Altelaar, A. F. M., Hennrich, M. L., Nolting, D., Zeller, M., Griep-Raming, J., Heck, A. J. R., & Mohammed, S. (2011) · Journal of Proteome Research · doi:10.1021/pr1011729 · Cited by 312
Li, Z., Adams, R. M., Chourey, K., Hurst, G. B., Hettich, R. L., & Pan, C. (2012) · Journal of Proteome Research · doi:10.1021/pr200748h · Cited by 302
An insight into iTRAQ: where do we stand now?
Evans, C., Noirel, J., Ow, S. Y., Salim, M., Pereira-Medrano, A. G., Couto, N., Pandhal, J., Smith, D., Pham, T. K., Karunakaran, E., et al. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-5918-6 · Cited by 300
Kelstrup, C. D., Young, C., Lavallee, R., Nielsen, M. L., & Olsen, J. V. (2012) · Journal of Proteome Research · doi:10.1021/pr3000249 · Cited by 281
Measuring and Managing Ratio Compression for Accurate iTRAQ/TMT Quantification
Savitski, M. M., Mathieson, T., Zinn, N., Sweetman, G., Doce, C., Becher, I., Pachl, F., Kuster, B., & Bantscheff, M. (2013) · Journal of Proteome Research · doi:10.1021/pr400098r · Cited by 276
Wang, H., Alvarez, S., & Hicks, L. M. (2012) · Journal of Proteome Research · doi:10.1021/pr2008225 · Cited by 142
Metadata
- Authors
- Köcher, T., Pichler, P., Schutzbier, M., Stingl, C., Kaul, A., Teucher, N., Hasenfuss, G., Penninger, J. M., & Mechtler, K.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-08-27
- Volume
- 8
- Issue
- 10
- Pages
- 4743-4752
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W2145820743
- Cited by
- 152
- References
- 10
- FWCI
- 9.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.