CoChat

Immunoaffinity/Gas Chromatography/High-Resolution Mass Spectrometry Method for the Detection of N2,3-Ethenoguanine

Ham, Amy-Joan L., Ranasinghe, Asoka, Morinello, Eric J., Nakamura, Jun, Upton, Patricia B., Johnson, Francis, Swenberg, James A. · 1999 · Chemical Research in Toxicology
Cited by 38

The DOI matches its Crossref record.

Abstract

Etheno adducts are formed after exposure to a number of carcinogens, including vinyl chloride, as well as endogenously as a result of lipid peroxidation. A sensitive and selective assay for N(2), 3-ethenoguanine (epsilonGua) was developed using immunoaffinity (IA) columns made with polyclonal antibodies to epsilonGua followed by gas chromatography/electron capture negative chemical ionization/high-resolution mass spectrometry (GC/ECNCI/HRMS) analysis of its pentafluorobenzyl derivative. These IA columns were specific for epsilonGua and did not bind guanine, deoxyguanosine, 1, N(6)-ethenoadenine, or 1,N(2)-ethenoguanine. The level of recovery of standards from the IA columns was 107 +/- 7% and throughout the entire method (using nucleoside enzymatic digestion) with or without DNA was 72 +/- 6%. Four different hydrolysis/digestion procedures were compared, nucleoside enzymatic (EZ), neutral thermal hydrolysis (NT), formic acid hydrolysis (FA), and HCl hydrolysis. All hydrolysis methods with subsequent IA chromatography produced linear standard curves with r(2) values of 0.999 or better. The level of epsilonGua in chloroethylene oxide-treated calf thymus DNA (CEO-ctDNA) was 38 +/- 2, 42 +/- 3, and 49 +/- 2 fmol of epsilonGua/microg of DNA using EZ, NT, and FA, respectively. These numbers remained consistent when the amount of DNA processed was doubled or tripled. These numbers were comparable to the previously published value of 55 +/- 8 fmol of epsilonGua/micrograms of DNA for the same DNA using HCl hydrolysis, cation exchange cleanup, and LC/MS analysis [Yen, T. Y., et al. (1996) J. Mass Spectrom. 31, 1271-1276]. Additionally, HCl hydrolysis of rat liver DNA from control and vinyl fluoride-exposed rats gave similar epsilonGua results when compared to those from enzymatic digestion using this method. This method gave a detection limit of 5 epsilonGua adducts/10(8) normal dGuo nucleosides in 150 micrograms of DNA using EZ and somewhat lower detection limits using NT and HCl hydrolysis. The method is more sensitive and selective than previously used methods for the quantitation of this adduct.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/tx990150r

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 38

Metadata

Authors
Ham, A.-J. L., Ranasinghe, A., Morinello, E. J., Nakamura, J., Upton, P. B., Johnson, F., & Swenberg, J. A.
Venue
Chemical Research in Toxicology
Published
1999-11-19
Volume
12
Issue
12
Pages
1240-1246
ISSN
  • 0893-228X (ISSN-L)
  • 1520-5010
OpenAlex
W1990685264
Cited by
38
References
0
FWCI
1.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Immunoaffinity/Gas Chromatography/High-Resolution Mass Spectrometry Method for the Detection of N2,3-Ethenoguanine. https://app.cochat.ai/papers/10.1021/tx990150r
The paper
Ham, A.-J. L., Ranasinghe, A., Morinello, E. J., Nakamura, J., Upton, P. B., Johnson, F., & Swenberg, J. A. (1999). Immunoaffinity/Gas Chromatography/High-Resolution Mass Spectrometry Method for the Detection of N2,3-Ethenoguanine. Chemical Research in Toxicology. https://doi.org/10.1021/tx990150r

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.