The DOI matches its Crossref record; 74 of the 76 references it cites were found in a registry or an index.
Clinical Relevance of Silent Atrial Fibrillation: Prevalence, Prognosis, Quality of Life, and Management
Abstract
Although first described about 100yr ago, atrial fibrillation (AF) is now recognized as the most common of all arrhythmias. It has a substantial morbidity and presents a considerable health care burden. Improved diagnosis and an ageing population with an increased likelihood of underlying cardiac disease results in AF in more than 1% of population. AF is associated with an approximately two-fold increase in mortality, largely due to stroke which occurs at an annual rate of 5-7%. Another risk to survival is heart failure, which is aggravated by poor control of the ventricular rate during AF. Usually AF is associated with a variety of symptoms: palpitations, dyspnea, chest discomfort, fatigue, dizziness, and syncope. Paroxysmal AF is likely to be symptomatic and frequently presents with specific symptoms, while permanent AF is usually associated with less specific symptoms. However, in at least one third of patients, no obvious symptoms or noticeable degradation of quality of life are observed. This asymptomatic, or silent, AF is diagnosed incidentally during routine physical examinations, pre-operative assessments or population surveys. Recently, a very large incidence of generally short paroxysms of AF has been seen in patients with implantable pacemakers or defibrillators and these arrhythmias are often silent. Pharmacological suppression of arrhythmia may be associated with a conversion from a symptomatic to an asymptomatic form of AF. Holter monitoring and transtelephonic monitoring studies have demonstrated that asymptomatic episodes of AF exceed symptomatic paroxysms by twelve-fold or more. Although symptoms may not stem directly from AF, the risk of complications is probably the same for symptomatic and asymptomatic patients. AF is found incidentally in about 25% of admissions for a stroke. Studies in patients with little or no awareness of their arrhythmia condition indicate that unrecognized and untreated AF may cause congestive heart failure. In patients with coronary bypass, AF may not only represent risk for immediate postoperative morbidity and increase hospital resource utilization, but being unrecognized, may produce a significant impact on long-term survival and quality of life. Although silent AF merits consideration for anticoagulation and rate control therapy according to standard criteria, whether antiarrhythmic therapy is relevant in this condition remains unclear.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Silent, undetected AF is common, 120,122 with severe consequences such as stroke and death.[123][124][125]”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [122]
Citations
Cites
Atrial fibrillation as an independent risk factor for stroke: the Framingham study
Wolf, P. A., Abbott, R. D., & Kannel, W. B. (1991) · Stroke · doi:10.1161/01.str.22.8.983 · Cited by 7,388
Benjamin, E. J. (1994) · JAMA · doi:10.1001/jama.1994.03510350050036 · Cited by 2,613
Epidemiologic Features of Chronic Atrial Fibrillation
Kannel, W. B., Abbott, R. D., Savage, D. D., & McNamara, P. M. (1982) · New England Journal of Medicine · doi:10.1056/nejm198204293061703 · Cited by 2,304
Krahn, A. D., Manfreda, J., TATE, R. B., Mathewson, F. A. L., & Cuddy, T. E. (1995) · The American Journal of Medicine · doi:10.1016/s0002-9343(99)80348-9 · Cited by 1,478
Incidence of and risk factors for atrial fibrillation in older adults
Psaty, B. M., Manolio, T. A., Kuller, L. H., Kronmal, R. A., Cushman, M., Fried, L. P., White, R., Furberg, C. D., & Rautaharju, P. M. (1997) · Circulation · doi:10.1161/01.cir.96.7.2455 · Cited by 1,462
Atrial Fibrillation: A Major Contributor to Stroke in the Elderly: The Framingham Study
Wolf, P. A. (1987) · Archives of Internal Medicine · doi:10.1001/archinte.1987.00370090041008 · Cited by 1,108
Prevalence of atrial fibrillation in elderly subjects (the Cardiovascular Health Study)
Furberg, C. D., Psaty, B. M., Manolio, T. A., Gardin, J. M., Smith, V. E., & Rautaharju, P. M. (1994) · The American Journal of Cardiology · doi:10.1016/0002-9149(94)90363-8 · Cited by 1,096
The Natural History of Lone Atrial Fibrillation
Kopecky, S. L., Gersh, B. J., McGoon, M. D., Whisnant, J. P., Holmes, D. R., Ilstrup, D. M., & Frye, R. L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198709103171104 · Cited by 936
Atrial Fibrillation and Dementia in a Population-Based Study: The Rotterdam Study
Ott, A., Breteler, M. M. B., de Bruyne, M. C., van Harskamp, F., Grobbee, D. E., & Hofman, A. (1997) · Stroke · doi:10.1161/01.str.28.2.316 · Cited by 732
Page, R. L., Wilkinson, W. E., Clair, W. K., McCarthy, E. A., & Pritchett, E. L. (1994) · Circulation · doi:10.1161/01.cir.89.1.224 · Cited by 627 · cited 1×
“6% of calls which were not associated with symptoms [25].”
Background
Flagged first, then by citations
2 of the 76 references couldn’t be matched to a known paper.
Research works printed but not linked: 6
- Garrigue S, Cazeau S, Ritter P, Lazarus A, Gras D, Mugica J. [Incidence of atrial arrhythmias in patients with dual-chamber pacemakers: value of the pacemaker Holter function] [French]. Arch Mal Coeur Vas 1996;89:873-881.
- Lombardi F, Tozillo D, Cappiello E. Sympatho-vagal influence in atrial fibrillation. N Trends Arrhythmias 1993;9:179-184.
- Feinberg WM, Seeger JF, Carmody RF, Anderson DC, Hart RG, Pearce LA. Asymptomatic cerebral infarction in patients with atrial fibrillation. Circulation 1988;19:955-957.
- Kulbertus HE, de Leval-Rutten F, Bartsch P, Petit JM. Atrial fibrillation in elderly, anbulatory patients. In: Kulbertus HE, Olsson SB, Schlepper M, eds. Atrial fibrillation. Mölndal: AB Hässle, 1982:148-157.
- Howes CJ, Brandt C, Yerkey MW, Ruo B, Reid C, Ezekowitz MD. Quality of life and exercise tolerance in elderly, ambulatory patients with chronic atrial fibrillation. Circulation 1998;98(Suppl):I-703-I-704 (abstr).
- Paquette M, Roy D, Talajic M, Newman D, Dorian P, for the CTAF Investigators. Sinus rhythm at the time of assessment is associated with better quality of life than atrial fibrillation or flutter results from the Canadian Trial of Atrial Fibrillation. PACE 1999;22: 863(abstr).
Cited by
Sorted by citations
Items 201–300 of 340
Boulos, M. N. K., & Haywood, G. A. (2021) · mHealth · doi:10.21037/mhealth-19-204 · Cited by 9
Denas, G., Battaggia, A., Fusello, M., Novelletto, B. F., Cancian, M., Scalisi, A., & Pengo, V. (2020) · International Journal of Cardiology · doi:10.1016/j.ijcard.2020.08.097 · Cited by 8
Hansen, T., Pottegård, A., Brandes, A., Ekelund, U. E. G., Kildegaard, H., Forberg, J. L., Brabrand, M., & Lassen, A. T. (2019) · The American Journal of Medicine · doi:10.1016/j.amjmed.2019.06.048 · Cited by 8
Caldwell, J. C., Borbas, Z., Donald, A., Clifford, A. G., Bolger, L. E., Black, A. L., Corden, J., & Fitzpatrick, A. P. (2011) · EP Europace · doi:10.1093/europace/eur304 · Cited by 8
“Spot” ECGs Underestimate Atrial Fibrillation Recurrence after Surgical Ablation
Puskas, J. D., Corvera, J. S., Neill, A. A., Kilgo, P., Vassiliades, T. A., & Guyton, R. A. (2008) · Innovations Technology and Techniques in Cardiothoracic and Vascular Surgery · doi:10.1097/imi.0b013e318164aa89 · Cited by 7
Increasing the reach: optimizing screening for atrial fibrillation—the STROKESTOP III study
Khan, M., Ingre, M., Carlstedt, F., Eriksson, A., Skröder, S., Tenn, J. S., Rosenqvist, M., & Svennberg, E. (2024) · EP Europace · doi:10.1093/europace/euae234 · Cited by 7
Passive Capacitive ECG Sensing: Assessment of Signal Quality During Different Types of Body Movement
Kirchner, J., Pfeiffer, S., & Fischer, G. (2018) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2018.8438791 · Cited by 7
Chu, S., Jiang, J., Wang, Y., Sheng, Q.-H., Zhou, J., & Ding, Y. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.654532 · Cited by 7
Smartphone and new tools for atrial fibrillation diagnosis: evidence for clinical applicability
PAPACCIOLI, G., BASSI, G., Cecilia, L. U. G. I., Parente, E., D’ANDREA, A., PROIETTI, R., Imbalzano, E., TURKI, A. A., & Russo, V. (2022) · Minerva Cardiology and Angiology · doi:10.23736/s2724-5683.22.05841-0 · Cited by 7
Atrial fibrillation: advances and perspectives
Camm, A. J., & Savelieva, I. (2003) · Cited by 7
Self-citationCori, A. D., Lilli, A., Zucchelli, G., & Zacà, V. (2018) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2018.1438267 · Cited by 8
A Clinical Perspective on Atrial Fibrillation
Platonov, P. G., & Corino, V. (2018) · Series in bioengineering · doi:10.1007/978-3-319-68515-1_1 · Cited by 7
Atrial Fibrillation Monitoring
Hindricks, G., & Piorkowski, C. (2012) · Circulation · doi:10.1161/circulationaha.112.124735 · Cited by 7
Strategies for prediction and early detection of atrial fibrillation: present and future
García-Fernández, A., Roldán, V., & Marín, F. R. (2016) · EP Europace · doi:10.1093/europace/euw131 · Cited by 7
Explanation of HRV Features for Detecting Atrial Fibrillation
Lee, Y., Pham, V., & Chung, T. (2022) · SN Computer Science · doi:10.1007/s42979-022-01309-4 · Cited by 6
Rapacciuolo, A., Mancusi, C., Canciello, G., Izzo, R., Strisciuglio, T., LUCA, N. D., Ammirati, G., SIMONE, G. D., Trimarco, B., & Losi, M. A. (2019) · Scientific Reports · doi:10.1038/s41598-019-44214-2 · Cited by 6
Photoplethysmography-Based Smart Devices for Detection of Atrial Fibrillation
Sijerčić, A., & Tahirović, E. (2022) · Texas Heart Institute Journal · doi:10.14503/thij-21-7564 · Cited by 6
Prevalence of cardiac arrhythmias in a community based chiropractic practice.
Padhi, S., Patel, N., Driscoll, D., & Budgell, B. (2014) · Europe PMC (PubMed Central) · Cited by 6
Vachev, S., Bogachev-Prokof'ev, A. V., Зотов, А. С., Анатольевич, Е. Д., Voronin, S. V., Троицкий, А. В., & Khabazov, R. I. (2019) · Angiology and vascular surgery · doi:10.33529/angio2019416 · Cited by 7
Yi, J., Lee, Y. S., Choi, E., Cha, M., Kim, T., Park, J., Lee, J., Kang, K., Uhm, J., Uhm, J., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-36185-7 · Cited by 5
Silent brain infarcts in high blood pressure patients with cardiac implantable electronic devices
Benezet‐Mazuecos, J., Iglesias, J. A., Cortés, M., de la Vieja, J. J., Campal, J. M. R., Sanchez-Borque, P., & Farré, J. (2015) · Journal of Hypertension · doi:10.1097/hjh.0000000000000787 · Cited by 5
When Silence Isn’t Golden: The Case of “Silent” Atrial Fibrillation
Reiffel, J. A. (2017) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2017.081102 · Cited by 5
Papakonstantinou, P. Ε., & SIMANTIRAKIS, E. N. (2019) · Minerva Cardioangiologica · doi:10.23736/s0026-4725.19.04883-7 · Cited by 5
Magnusson, P., Lyren, A., & Mattsson, G. (2020) · BMJ Open · doi:10.1136/bmjopen-2020-037360 · Cited by 6
Blood Pressure Control versus Atrial Fibrillation Management in Stroke Prevention
Savoia, C., Sada, L., & Volpe, M. (2015) · Current Hypertension Reports · doi:10.1007/s11906-015-0553-1 · Cited by 5
Morais, J., Osterspey, A., Tamargo, J. L., Zamorano, L., Despres, C., Dickstein, K., Lekakis, J. P., McGregor, K., Metra, M., Budaj, A., et al. (2006) · Cited by 5
Self-citationControversies in ablation of atrial fibrillation
Aliot, E., & Ruskin, J. N. (2008) · European Heart Journal Supplements · doi:10.1093/eurheartj/sun030 · Cited by 5
Anesthesia Complications in Head and Neck Surgery
Lobo, E., Pellegrini, F., & Pusceddu, E. (2009) · Elsevier eBooks · doi:10.1016/b978-141604220-4.50005-5 · Cited by 5
Bergau, L., Sohns, C., Sossalla, S. T., Expósito, P. M., Lüthje, L., & Zabel, M. (2015) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-014-9970-3 · Cited by 4
Atrial Fibrillation in Hypertension: Patients' Characteristics
Koutsaki, S., Koutelekos, I. G., Gerogianni, G., Koutsaki, M., Koukouzeli, A., Fouka, G., & Polikandrioti, M. (2018) · Materia Socio Medica · doi:10.5455/msm.2018.30.4-9 · Cited by 4
Qammar, N. W., Šiaučiūnaitė, V., Zabiela, V., Vainoras, A., & Ragulskis, M. K. (2022) · Diagnostics · doi:10.3390/diagnostics12122919 · Cited by 4
Managing newly diagnosed atrial fibrillation: Rate, rhythm, and risk
Callahan, T. D., & Baranowski, B. (2011) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.78a.09165 · Cited by 4
Evaluación de la fibrilación auricular mediante electrocardiograma y Holter
Mora-Pabón, G. (2016) · Revista Colombiana de Cardiología · doi:10.1016/j.rccar.2016.10.006 · Cited by 4
Forleo, G. B., Biase, L. D., Rocca, D. G. D., Fassini, G. M., Santini, L., Natale, A., & Tondo, C. (2013) · Europe PMC (PubMed Central) · doi:10.4022/jafib.961 · Cited by 4
Is it safe to stop oral anticoagulation after catheter ablation for atrial fibrillation?
Romero, J. E., Avendaño, R., Díaz, J. C., Taveras, J. M., Lupercio, F. A., & Biase, L. D. (2018) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2019.1550718 · Cited by 4
Tang, E. W. L., Yip, B. H. K., Yu, C., Wong, S. Y. S., & Lee, E. K. P. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.956542 · Cited by 5
Fibricheck detection capabilities for atrial fibrillation (FDA–AF): a multicenter validation study
Sollee, J., Cheema, B. S., Slotwiner, D. J., Volodarskiy, A., Desteghe, L., Buyck, C., Heidbüchel, H., Stavrakis, S., Pison, L., Nuyens, D., et al. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-02059-2 · Cited by 3
Simova, I. I. (2013) · Cardiology and Angiology An International Journal · doi:10.9734/ca/2013/6802 · Cited by 3
Subclinical atrial fibrillation: when to give NAO?
Patti, G., & Sticchi, A. (2020) · European Heart Journal Supplements · doi:10.1093/eurheartj/suaa072 · Cited by 2
Kumar, S. S., Andreakou, E., Tzachsan, M., & Maier, A. M. (2023) · Proceedings of the Design Society · doi:10.1017/pds.2023.258 · Cited by 3
Imtiaz, K., Ebrahim, M., Niu, J., & Roberts, J. (2024) · Journal of the Society for Cardiovascular Angiography & Interventions · doi:10.1016/j.jscai.2024.101930 · Cited by 3
Shurrab, M., Janmohamed, A., Paredes, F. A., Sturmer, M., Toal, S. C., SARRAZIN, J., Thorpe, K. E., Sterns, L. D., Healey, J. S., & Crystal, E. (2024) · Heart Rhythm O2 · doi:10.1016/j.hroo.2024.07.014 · Cited by 3
Demirtaş, A. O., İçen, Y. K., Dönmez, Y., Koca, H., Kaypaklı, O., & Koç, M. (2019) · Archives of Medical Science - Atherosclerotic Diseases · doi:10.5114/amsad.2019.85375 · Cited by 3
Handheld ECG Tracking of in-hOspital Atrial Fibrillation The HECTO-AF trial Clinical Study Protocol
Schukraft, S., Mancinetti, M., Hayoz, D., Faucherre, Y., Cook, S., Arroyo, D., & Puricel, S. (2019) · Trials · doi:10.1186/s13063-019-3189-7 · Cited by 3
Cryptogenic stroke—can we abandon this apologetic diagnosis?
Camm, A. J. (2014) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2014.111 · Cited by 3
Self-citationThe involvement of pharmacies in the screening of undiagnosed atrial fibrillation
Modesti, P. A., Donigaglia, G., Fabiani, P., Mumoli, N., Colella, A., & Boddi, M. (2017) · Internal and Emergency Medicine · doi:10.1007/s11739-017-1752-3 · Cited by 3
Naccarelli, G. V., & Curtis, A. B. (2010) · Journal of Cardiovascular Pharmacology and Therapeutics · doi:10.1177/1074248410370964 · Cited by 3
Monitoring of Atrial Tachyarrhythmias
Mehra, R. (2002) · Cardiac Electrophysiology Review · doi:10.1023/a:1016372823942 · Cited by 3
Schuchert, A., Frost, G., & Meinertz, T. (2004) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/b:jice.0000042353.87671.1d · Cited by 3
Reiter, M. J., Harsch, M. R., Lung, T., Munneke, D., Kim, M. H., & Shalaby, A. A. (2008) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2008.09.002 · Cited by 3
Atrial fibrillation – all change!
Savelieva, I., & Camm, A. J. (2007) · Clinical Medicine · doi:10.7861/clinmedicine.7-4-374 · Cited by 2
Self-citationTemperament, stress, and atrial fibrillation
Maryniak, A., Hasiec, A., Duda, B., Orczykowski, M., & Szumowski, Ł. J. (2015) · Polish Psychological Bulletin · doi:10.1515/ppb-2015-0030 · Cited by 2
Jackson, A., Fröbert, O., Larsen, D. B., Arendt‐Nielsen, L., & Björkenheim, A. (2021) · Open Heart · doi:10.1136/openhrt-2021-001699 · Cited by 2
Pulse deficit in atrial fibrillation — a different perspective on rhythm or rate control strategy
Karadavut, S., & Altıntop, İ. (2021) · Kardiologia Polska · doi:10.33963/kp.a2021.0107 · Cited by 2
Atrial fibrillation and 24‐h ambulatory blood pressure pattern
Verberk, W. J. (2022) · Journal of Clinical Hypertension · doi:10.1111/jch.14522 · Cited by 2
Neue notfallmedizinische Trends in der EKG-Diagnostik – Arrhythmie, Ischämie und plötzlicher Herztod
Grautoff, S., Fessele, K., Bastian, D., & Knappen, N. (2024) · Notfall + Rettungsmedizin · doi:10.1007/s10049-024-01292-8 · Cited by 2
Qammar, N. W., Vainoras, A., Navickas, Z., Jaruševičius, G., & Ragulskis, M. K. (2024) · Applied Sciences · doi:10.3390/app14146191 · Cited by 2
Atrial Fibrillation Detection System via Acoustic Sensing for Mobile Phones
Liu, X., Li, J., Liu, H., Yang, Z., Huang, Y., & Zhang, J. (2025) · ACM Transactions on Sensor Networks · doi:10.1145/3771548 · Cited by 2
Dronedarone: a new option in atrial fibrillation
Camm, A. J., & Savelieva, I. (2009) · Future Prescriber · doi:10.1002/fps.45 · Cited by 2
Self-citationMusa, A. F., Dillon, J., Taib, M. E. M., Yunus, A. M., Nordin, R. B., & Hay, Y. K. (2018) · F1000Research · doi:10.12688/f1000research.12912.2 · Cited by 2
Atrial Fibrillation and the Role of Thumb ECGs
Magnusson, P., Samuelsson, M., Pergolizzi, J. V., Annabi, H. M., & LeQuang, J. A. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.83660 · Cited by 2
Sharma, A., & Patidar, S. (2018) · Advances in medical diagnosis, treatment, and care (AMDTC) book series · doi:10.4018/978-1-5225-7131-5.ch009 · Cited by 2
Cost-Effectiveness of Atrial Fibrillation Screening Strategies: A Systematic Review
Gorji, H. A., Khosravi, M., Mahmoodi, R., Hasoumi, M., Souresrafil, A., Alipour, V., Rezapour, A., Hajahmadi, M., & Azari, S. (2023) · Iranian Journal of Public Health · doi:10.18502/ijph.v52i4.12435 · Cited by 2
Alhotye, M., Evans, R. A., Ng, G. A., & Singh, S. J. (2024) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-024-01000-6 · Cited by 2
Find AF—Efforts to find patients with atrial fibrillation—
Okabe, S., 明善, 佐., 康夫, 田., 陽子, 藤., Sugiyama, K., 仁智, 布., & Kamata, K. (2014) · Nosotchu · doi:10.3995/jstroke.36.403 · Cited by 2
Silent Paroxysmal Atrial Fibrillation Detection by Neural Networks Based on ECG Records
Aligholipour, O., Kuntalp, M., & Sadaghiyanfam, S. (2019) · Electric Electronics, Computer Science, Biomedical Engineerings' Meeting (EBBT) · doi:10.1109/ebbt.2019.8741771 · Cited by 2
Guidelines for Anticoagulation of Atrial Fibrillation: Is It Time for an Update?
Waldo, A. L. (2006) · Springer eBooks · doi:10.1007/88-470-0371-7_23 · Cited by 2
Self-limited bursts of atrial fibrillation following successful cardioversion
Nergårdh, A., Rosenqvist, M., & Frick, M. (2006) · International Journal of Cardiology · doi:10.1016/j.ijcard.2006.08.007 · Cited by 2
Atrial fibrillation ablation:role of patient enrollment and follow-up in clinical results
Turco, P., Stabile, G., Simone, A. D., & Jamal, B. E. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00047-0 · Cited by 2
Atrial Fibrillation: Antiarrhythmic Therapy
Crijns, H. J. G. M., Gelder, I. C. V., Savelieva, I., & Camm, A. J. (2002) · Wiley eBooks · doi:10.1002/9780470986882.ch37 · Cited by 2
Self-citationDeep learning approaches for the cardiovascular disease diagnosis using smartphone
Subaşı, A., Kontio, E., & Jafaritadi, M. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-90548-0.00010-3 · Cited by 1
Araújo, I., Fonseca, C., Cardiga, R., Dores, H., Ferreira, R., Gândara, F., Proença, M., Marques, F., Leitão, A., & Ceia, F. (2012) · European Geriatric Medicine · doi:10.1016/j.eurger.2012.10.004 · Cited by 1
The Feasibility of Fully Automated Pacemaker Advise in Treating Atrial Tachyarrhythmias
Ruiter, J. H., MULDER, E., Schuchert, A., Burri, H., Stuehlinger, M., Hartikainen, J. E. K., Sermasi, S., Vlašínová, J., Mairesse, G. H., Bub, E., et al. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02689.x · Cited by 1
Anticoagulation Management in Patients with Pacemaker-Detected Atrial Fibrillation
Poposka, L., Boskov, V., Risteski, D., Taleski, J., & Georgievska‐Ismail, L. (2016) · Open Access Macedonian Journal of Medical Sciences · doi:10.3889/oamjms.2016.053 · Cited by 2
Symptoms of Atrial Fibrillation
Dadkhah, S., & Sharain, K. (2016) · Contemporary cardiology · doi:10.1007/978-3-319-31386-3_5 · Cited by 1
AcousAF: Acoustic Sensing-Based Atrial Fibrillation Detection System for Mobile Phones
Liu, X., Liu, H., Li, J., Yang, Z., Huang, Y., & Zhang, J. (2024) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/3675094.3678488 · Cited by 1
Classification, Diagnosis, and Assessment of Atrial Fibrillation
Yap, Y. G., & Camm, A. J. (2014) · doi:10.1007/978-1-907673-98-6_3 · Cited by 1
Self-citationDiagnóstico, tratamiento y seguimiento de la fibrilación auricular en atención primaria
Cubillo, Á. C. M., Herguedas, E. M., & González, L. P. (2018) · FMC - Formación Médica Continuada en Atención Primaria · doi:10.1016/j.fmc.2018.01.002 · Cited by 1
Koo, K., Inglis, S. C., Freedman, B., Thijs, V., & Ferguson, C. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013464 · Cited by 1
RetractedFuster, V., Ryden, L. E., Cannom, D. S., Crijns, H. J. G. M., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Heuzey, J. Y. L., Kay, G. N., Lowe, J. E., et al. (2007) · Rational Pharmacotherapy in Cardiology · doi:10.20996/1819-6446-2007-3-2-72-97 · Cited by 1
Atrial Fibrillation: Rhythm and Rate Control Therapies
Savelieva, I., Waldo, A. L., & Camm, A. J. (2009) · Wiley eBooks · doi:10.1002/9781444309768.ch35 · Cited by 1
Self-citationComplications and Definition of Success
Shapira, A. R., & Wilber, D. J. (2008) · Humana Press eBooks · doi:10.1007/978-1-59745-163-5_20 · Cited by 1
Du, C. Q. (2003) · Cited by 1
Quality of Life in Patients With Atrial Fibrilation
Camm, A. J. (2010) · Revista Española de Cardiología (English Edition) · doi:10.1016/s1885-5857(10)70271-1 · Cited by 1
Self-citationTronconi, F., Porciani, M. C., Gianfranchi, L., CORBUCCI, G., & Padeletti, L. (2004) · Cardiovascular Engineering An International Journal · doi:10.1023/b:care.0000038778.66625.f6 · Cited by 1
Hendrikx, T. (2015) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 1
E-monitoring solutions for sleep apnea diagnosis and blood pressure measurement
Lazazzera, R. (2020) · doi:10.70675/09475fc7za50ez41e2z92c5zb4b50e0c5ed5 · Cited by 1
Atrial Fibrillation Should Be Considered a First-Line Therapy — Or Not?
Pacifico, A., & Henry, P. D. (2006) · Springer eBooks · doi:10.1007/88-470-0371-7_33
Circadian Pattern of AF Paroxysms
Michelucci, A., Pieragnoli, P., Colella, A., Gensini, G., & Padeletti, L. (2004) · doi:10.1002/9780470987483.ch51
Wearable Wireless Sensor for Multi-Scale Physiological Monitoring
Chon, K. H., & Mendelson, Y. (2013) · doi:10.21236/ada590832
Active Supraventricular Arrhythmias
de Luna, A. B. (2011) · Wiley eBooks · doi:10.1002/9781444391749.ch4
Autonomic Influence of Atrial Fibrillation
Coumel, P. (2004) · doi:10.1002/9780470987483.ch55
Ma, S., van Hemel, N. M., Jc, K., Yee, R. R., Re, L., Táborský, M., & Grobbee, D. E. (2006) · PubMed Central
Long Time Monitoring of Cardiac Rhythm in Patients With Atrial Fibrillation
Kesek, M., & Rosenqvist, M. (2004) · doi:10.1002/9780470987483.ch56
Zarse, M., SCHAUERTE, P. N., Mühlenbruch, G., Waldmann, M., Plisienė, J., Schimpf, T., Mischke, K., Sinha, A. M., Knackstedt, C., Schöndube, F. A., et al. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00490.x
Atrial fibrillation 2: assessment and diagnosis
Cottrell, C. (2012) · Practice Nursing · doi:10.12968/pnur.2012.23.2.70
Atrial fibrillation 1: classification and clinical implications
Alchaghouri, S. (2004) · Hospital Medicine · doi:10.12968/hosp.2004.65.8.15492
Atrial fibrillation in cardiac implantable electronic devices and the duck test
Benezet‐Mazuecos, J., Campal, J. M. R., & Farré, J. (2014) · American Heart Journal · doi:10.1016/j.ahj.2014.02.004
Metadata
- Authors
- Savelieva, I., & Camm, A. J.
- Affiliations
- St George's, University of London (GB)
- Venue
- Journal of Interventional Cardiac Electrophysiology
- Published
- 2000-06
- Volume
- 4
- Issue
- 2
- Pages
- 369-382
- ISSN
- 1383-875X (ISSN-L)
- 1572-8595
- OpenAlex
- W107386444
- Cited by
- 339
- References
- 76
- Citations by year
- 2026: 4 · 2025: 4 · 2024: 11 · 2023: 8 · 2022: 14 · 2021: 9 · 2020: 18 · 2019: 20 · 2018: 24 · 2017: 21 · 2016: 23 · 2015: 21 · 2014: 18 · 2013: 12 · 2012: 19
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Journal of Interventional Cardiac Electrophysiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Cardiovascular and Diving-Related Complications
- Keywords
- silent atrial fibrillation, asymptomatic atrial fibrillation, atrial fibrillation prevalence, atrial fibrillation prognosis, quality of life, stroke risk, heart failure, ventricular rate control, antiarrhythmic therapy, anticoagulation, cardiac implantable electronic devices, Holter monitoring, transtelephonic monitoring, coronary artery bypass grafting, mortality
- MeSH terms
- Atrial Fibrillation, Humans, Prognosis, Quality of Life, Prevalence
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review