Continuous glucose monitoring in children with glycogen storage disease type I
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Glycogen storage disease type I (GSD I) is characterized by impaired production of glucose from glycogenolysis and gluconeogenesis resulting in severe fasting hypoglycaemia. The aim of the present study was to examine the efficacy of a continuous subcutaneous glucose monitoring system (CGMS MiniMed), to determine the magnitude and significance of hypoglycaemia in GSD I and to evaluate the efficacy of its dietary treatment. Four children with GSD I were studied over a 72‐h period. Results indicated that the values recorded with continuous subcutaneous glucose monitoring were highly correlated with paired blood glucose values measured by glucometer. Significant periods of asymptomatic hypoglycaemia were noted, especially during night‐time. The study suggests that repeated continuous subcutaneous glucose monitoring may serve as a useful tool for the assessment of the long‐term management of GSD I patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bode, B. W., Gross, T. M., Thornton, K. R., & Mastrototaro, J. J. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00113-8 · Cited by 232 · cited 2×
“We examined the 72 h glucose pro¢les generated by the continuous glucose monitoring system (CGMS MiniMed, Sylmar, CA, USA) (Bode et al 1999; Mastrototaro 1999).”
BackgroundMethodCornstarch regimens for nocturnal treatment of young adults with type I glycogen storage disease
Wolfsdorf, J., & Crigler, J. (1997) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/65.5.1507 · Cited by 50
Wolfsdorf, J., Plotkin, R., Laffel, L., & Crigler, J. (1990) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/52.6.1043 · Cited by 43 · cited 2×
“GSD I is treated by the provision of a continuous dietary source of glucose to prevent blood glucose from falling below the threshold for glucose counterregulation, or approximately 4 mmol/L (70 mg/dl) (Chen et al 1984; Wolfsdorf et al 1990a).”
Background
Cited by
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Chen, R., Yogev, Y., Ben-Haroush, A., Jovanovic, L., Hod, M., & Phillip, M. (2003) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/jmf.14.4.256.260 · Cited by 101
Self-citationContinuous glucose monitoring for hypoglycaemia in children: perspectives in 2020
Worth, C., Dunne, M., Ghosh, A., Harper, S., & Banerjee, I. (2020) · Pediatric Diabetes · doi:10.1111/pedi.13029 · Cited by 37
“Several studies have demonstrated the utility of CGM in detecting unsuspected hypoglycaemia, particularly overnight.(46,47)”
BackgroundNocturnal hypoglycaemia in ACTH and GH deficient children: role of continuous glucose monitoring
Cambiaso, P., Schiaffini, R., Pontrelli, G., Carducci, C., Ubertini, G., Crea, F., & Cappa, M. (2013) · Clinical Endocrinology · doi:10.1111/cen.12123 · Cited by 21
Metadata
- Authors
- Hershkovitz, E., Rachmel, A., Ben‐Zaken, H., & Phillip, M.
- Venue
- Journal of Inherited Metabolic Disease
- Publisher
- Wiley
- Published
- 2001-12
- Volume
- 24
- Issue
- 8
- Pages
- 863-869
- ISSN
- 0141-8955 (ISSN-L)
- 1573-2665
- OpenAlex
- W1528076136
- Cited by
- 47
- References
- 3
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.