The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Intracerebral Sources of Human Auditory Steady-State Responses
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human auditory evoked potentials. I: Evaluation of components
Picton, T. W., Hillyard, S. A., Krausz, H. I., & Galambos, R. (1974) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(74)90155-2 · Cited by 1,468
Self-citationHuman Brain Electrophysiology: Evoked Potentials and Evoked Magnetic Fields in Science and Medicine
Regan, D. M. (1989) · Medical Entomology and Zoology · Cited by 1,300
A 40-Hz auditory potential recorded from the human scalp.
Galambos, R., Makeig, S., & Talmachoff, P. J. (1981) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.78.4.2643 · Cited by 1,247
Starr, A., Picton, T. W., Sininger, Y., Hood, L. J., & Berlin, C. I. (1996) · Brain · doi:10.1093/brain/119.3.741 · Cited by 988
Self-citationEvoked dipole source potentials of the human auditory cortex
Scherg, M., & Von Cramon, D. (1986) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(86)90014-6 · Cited by 707
Self-citationA Source Analysis of the Late Human Auditory Evoked Potentials
Scherg, M., Vajsar, J., & Picton, T. W. (1989) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1989.1.4.336 · Cited by 705
Self-citationLiégeois-Chauvel, C., Musolino, A., Badier, J. M., Marquis, P., & Chauvel, P. (1994) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(94)90064-7 · Cited by 652
Magnetic field tomography of coherent thalamocortical 40-Hz oscillations in humans.
Ribary, U., Ioannides, A. A., Singh, K. D., Hasson, R., Bolton, J. P., Lado, F., Mogilner, A., & Llinás, R. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.24.11037 · Cited by 541
Fundamentals if dipole source potential analysis
Scherg, M. (1990) · Max Planck Institute for Plasma Physics · Cited by 530
Self-citationThalamocortical transformation of responses to complex auditory stimuli
Creutzfeldt, O., Hellweg, F.-C., & Schreiner, C. (1980) · Experimental Brain Research · doi:10.1007/bf00237072 · Cited by 358
Cited by
Human auditory steady-state responses: Respuestas auditivas de estado estable en humanos
Picton, T. W., John, M. S., Dimitrijevic, A., & Purcell, D. (2003) · International Journal of Audiology · doi:10.3109/14992020309101316 · Cited by 846
Self-citationHuman EEG gamma oscillations in neuropsychiatric disorders
Herrmann, C. S., & Demiralp, T. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.07.007 · Cited by 599
Individual Differences Reveal Correlates of Hidden Hearing Deficits
Bharadwaj, H. M., Masud, S., Mehraei, G., Verhulst, S., & Shinn-Cunningham, B. G. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.3915-14.2015 · Cited by 314
The 40-Hz Auditory Steady-State Response in Patients With Schizophrenia: A Meta-analysis
Thuné, H., Recasens, M., & Uhlhaas, P. J. (2016) · JAMA Psychiatry · doi:10.1001/jamapsychiatry.2016.2619 · Cited by 292
Cochlear neuropathy and the coding of supra-threshold sound
Bharadwaj, H. M., Verhulst, S., Shaheen, L., Liberman, M. C., & Shinn-Cunningham, B. G. (2014) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2014.00026 · Cited by 284
Human temporal auditory acuity as assessed by envelope following responses
Purcell, D. W., John, S. M., Schneider, B. A., & Picton, T. W. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1798354 · Cited by 282
Self-citationBayesian model averaging in EEG/MEG imaging
Trujillo-Barreto, N. J., Aubert-Vázquez, E., & Valdés-Sosa, P. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.11.008 · Cited by 262
Left auditory cortex gamma synchronization and auditory hallucination symptoms in schizophrenia
Spencer, K. M., Niznikiewicz, M. A., Nestor, P. G., Shenton, M. E., & McCarley, R. W. (2009) · BMC Neuroscience · doi:10.1186/1471-2202-10-85 · Cited by 253
“, [9,10,26]), and since the dipole model we used is very similar to other published models based on EEG [29,30], we are confident in the validity of our results.”
BackgroundMethodEvolving perspectives on the sources of the frequency-following response
Coffey, E. B. J., Nicol, T., White-Schwoch, T., Chandrasekaran, B., Krizman, J., Skoe, E., Zatorre, R. J., & Kraus, N. (2019) · Nature Communications · doi:10.1038/s41467-019-13003-w · Cited by 207
Baseline gamma power during auditory steady-state stimulation in schizophrenia
M. Spencer, K. (2012) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2011.00190 · Cited by 155
Metadata
- Authors
- Herdman, A. T., Lins, O., Van Roon, P., Stapells, D. R., Scherg, M., & Picton, T. W.
- Venue
- Brain Topography
- Published
- 2002-12
- Volume
- 15
- Issue
- 2
- Pages
- 69-86
- ISSN
- 0896-0267 (ISSN-L)
- 1573-6792
- OpenAlex
- W1543088917
- Cited by
- 389
- References
- 51
- FWCI
- 3.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.