Detection of sea-water motion by nuclear precession
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The long memory of nuclear-spin Larmor precession can be utilized to detect small changes in precession phase angle. The detection of longrange, slow transport of sea water caused by internal waves or other disturbances would seem desirable. Consider how the transport of a volume element of spins in a liquid through a spatial, inhomogeneous, magnetic field affects the phase of Larmor precession. For simplicity, consider a volume element of spins at position x0 at time t = 0, and assume that this volume element moves with a constant velocity v in an inhomogeneous field H(x). The magnitude and direction of v is to be measured, and it is shown that v as small as 10−8 cm/sec is detectable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Self-citationTransient Nuclear Induction and Double Nuclear Resonance in Solids
Herzog, B., & Hahn, E. L. (1956) · Physical Review · doi:10.1103/physrev.103.148 · Cited by 177
Self-citation
Cited by
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Markl, M., Frydrychowicz, A., Kozerke, S., Hope, M., & Wieben, O. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23632 · Cited by 788
Characterization of anisotropy in high angular resolution diffusion‐weighted MRI
Frank, L. R. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10156 · Cited by 510
Encoding strategies for three‐direction phase‐contrast MR imaging of flow
Pelc, N. J., Bernstein, M. A., Shimakawa, A., & Glover, G. H. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010404 · Cited by 455
Three‐dimensional phase contrast angiography
Dumoulin, C. L., Souza, S. P., Walker, M. F., & Wagle, W. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910090117 · Cited by 432
Anisotropy in high angular resolution diffusion-weighted MRI
Frank, L. R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1125 · Cited by 389
E XPERIMENTAL AND C OMPUTATIONAL M ETHODS IN C ARDIOVASCULAR F LUID M ECHANICS
Taylor, C. A., & Draney, M. T. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.121944 · Cited by 285
Cardiovascular magnetic resonance phase contrast imaging
Nayak, K. S., Nielsen, J.-F., Bernstein, M. A., Markl, M., D. Gatehouse, P., M. Botnar, R., Saloner, D., Lorenz, C., Wen, H., S. Hu, B., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0172-7 · Cited by 264
Caprihan, A., & Fukushima, E. (1990) · Physics Reports · doi:10.1016/0370-1573(90)90046-5 · Cited by 234
Plewes, D. B., & Kucharczyk, W. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23642 · Cited by 220
“While Paul Lauterbur (28) was among the first to suggest this founding principle of MRI, there is early mention of variants of this idea as it relates to studies of the use of NMR for the detection of spin diffusion (4) and motion (8).”
BackgroundBlood flow imaging with MR: spin-phase phenomena.
von Schulthess, G. K., & Higgins, C. B. (1985) · Radiology · doi:10.1148/radiology.157.3.2997836 · Cited by 189
“This is equivalent to the statement that the higherorder terms of equation (1) may be neglected.”
Background
Metadata
- Authors
- Hahn, E. L.
- Venue
- Journal of Geophysical Research
- Publisher
- American Geophysical Union (AGU)
- Published
- 1960-02
- Volume
- 65
- Issue
- 2
- Pages
- 776-777
- ISSN
- 0148-0227 (ISSN-L)
- OpenAlex
- W2132019442
- Cited by
- 197
- References
- 2
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.