A method for oxygen isotope analysis of milligram quantities of water and some of its applications
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A method has been developed by which bromine pentafluoride and small amounts of water are reacted in a nickel vessel at 80°C to liberate oxygen in 100% yield. The oxygen is converted to CO2, which is analyzed on an isotope ratio mass spectrometer. The oxidation reaction takes place instantaneously, and the conversion of the liberated O to CO2 requires approximately 15 minutes. There are no measurable memory effects in the method and the reproducibility is ±0.1‰. A value of 1.0407 was determined for the CO2-H2O fractionation factor at 25°C, a number necessary for relating standards in use by various workers. This value is in exact agreement with that obtained by Compston and Epstein in the same laboratory using a reduction technique but is in serious disagreement with values determined by other workers. An application of this technique has been made to the study of a meteorological problem.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Craig, H. (1957) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(57)90024-8 · Cited by 4,170
Standard for Reporting Concentrations of Deuterium and Oxygen-18 in Natural Waters
Craig, H. (1961) · Science · doi:10.1126/science.133.3467.1833 · Cited by 2,013
Research works printed but not linked: 10
- Boyer, 1961, Simple procedure for conversion of oxygen of orthophosphate or water to carbon dioxide for oxygen-18 determination, Anal. Chem., 33, 1906, 10.1021/ac50154a036 · doi:10.1021/ac50154a036
- Clayton, 1963, The use of bromine pentafluoride in the extraction of oxygen from oxides and silicates for isotopic analysis, Geochim. Cosmochim. Acta, 27, 43, 10.1016/0016-7037(63)90071-1 · DOI · Paper page
- Compston, 1958, A method for the preparation of carbon dioxide from water vapor for oxygen isotope analysis (abstract), Trans. Am. Geophys. Union, 39, 511
- Epstein, 1953, Variations of the O18/O16 ratio in natural waters, Geochim. Cosmochim. Acta, 4, 213, 10.1016/0016-7037(53)90051-9 · DOI · Paper page
- Hoekstra, 1953, Direct determination of oxygen in less familiar metal oxides, Anal. Chem., 25, 1608, 10.1021/ac60083a009 · doi:10.1021/ac60083a009
- Majzoub, 1966, Une methode d'analyse isotopique de l'oxygène sur des microquantités d'eau; détermination des coefficients de partage a l'équilibre de l'oxygène 18 entre H2O et CO2; D2O et CO2, J. Chim. Phys., 63, 563, 10.1051/jcp/1966630563 · doi:10.1051/jcp/1966630563
- McKinney, 1950, Improvements in mass spectrometers for the measurement of small differences in isotope abundance ratios, Rev. Sci. Instr., 21, 724, 10.1063/1.1745698 · DOI · Paper page
- Nier, 1947, A mass spectrometer for isotope and gas analysis, Rev. Sci. Instr., 18, 398, 10.1063/1.1740961 · DOI · Paper page
- Silverman, 1951, The isotope geology of oxygen, Geochim. Cosmochim. Acta, 2, 26, 10.1016/0016-7037(57)90089-3 · DOI
- Staschewski, 1964, Experimentelle Bestimmung der O18/O16-Trennfaktoren in den Systemen CO2/ H2O und CO2/D2O, Ber. Bun. Phys. Chem., 68, 454, 10.1002/bbpc.19640680507 · DOI
Cited by
Compilation of stable isotope fractionation factors of geochemical interest
Friedman, I., & O'Neil, J. R. (1977) · Professional Paper · doi:10.3133/pp440kk · Cited by 2,691
Self-citationOxygen Isotope Fractionation in Divalent Metal Carbonates
O'Neil, J. R., Clayton, R. N., & Mayeda, T. K. (1969) · The Journal of Chemical Physics · doi:10.1063/1.1671982 · Cited by 2,549
Self-citationOxygen isotope exchange between quartz and water
Clayton, R. N., O'Neil, J. R., & Mayeda, T. K. (1972) · Journal of Geophysical Research · doi:10.1029/jb077i017p03057 · Cited by 1,513
Self-citationComparison of stable isotope reference samples
Coplen, T. B., Kendall, C., & Hopple, J. (1983) · Nature · doi:10.1038/302236a0 · Cited by 1,079
Tarutani, T., Clayton, R. N., & Mayeda, T. K. (1969) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(69)90108-2 · Cited by 663
Metadata
- Authors
- O'Neil, J. R., & Epstein, S.
- Venue
- Journal of Geophysical Research
- Publisher
- American Geophysical Union (AGU)
- Published
- 1966-10-15
- Volume
- 71
- Issue
- 20
- Pages
- 4955-4961
- ISSN
- 0148-0227 (ISSN-L)
- OpenAlex
- W2161247618
- Cited by
- 139
- References
- 2
- FWCI
- 9.91
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm, 17853 d)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A method for oxygen isotope analysis of milligram quantities of water and some of its applications. https://app.cochat.ai/papers/10.1029/jz071i020p04955
- The paper
- O'Neil, J. R., & Epstein, S. (1966). A method for oxygen isotope analysis of milligram quantities of water and some of its applications. Journal of Geophysical Research. https://doi.org/10.1029/jz071i020p04955
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.