CoChat

The effect of air filtration on airborne dog allergen

Green, R, Simpson, A, Custovic, A, Faragher, B, Chapman, M, Woodcock, A · 1999 · Allergy
Cited by 81

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background: Effective methods of reducing dog allergen are required to help alleviate symptoms in asthmatic patients sensitized to dog who refuse to part with their pet. The aim of this study was to investigate the use of the high efficiency particulate air (HEPA) filter air cleaner to reduce airborne Can f 1 in homes with a dog. Methods: The effect of a HEPA air cleaner was investigated in nine homes with a dog. Samples were collected from two rooms of each house concurrently, one of which contained the dog, on two separate days (active day – HEPA air cleaner on – and control day). Eight consecutive 1‐h samples were collected from each room with a high‐volume air sampler (airflow rate 60 l/min). Can f 1 was determined by monoclonal‐polyclonal antibody‐based ELISA. Results: Baseline airborne Can f 1 levels were 3.8‐fold greater when sampling was performed with a dog in the room (GM 27.1 ng Can f 1/m 3, range 2.63–329) than when the dog was elsewhere in the house (GM 7.1 ng Can f 1/m 3, range 0.69–27.2). When the dog was elsewhere in the house, airborne Can f 1 levels fell on both active and control days, but the magnitude of the reduction was significantly greater on the active days (P<0.05), and was approximately 90% from baseline. With the dog in the room, a significant fall in airborne Can f 1 was observed only on active days (75% from baseline), but not on control days (active vs control P<0.001). Conclusions: HEPA air cleaners reduce airborne Can f 1 in homes with dogs. Furthermore, preventing the access of the dog to the bedroom and possibly the living room may reduce the total allergen load inhaled.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1034/j.1398-9995.1999.00029.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 81

Metadata

Authors
Green, R., Simpson, A., Custovic, A., Faragher, B., Chapman, M., & Woodcock, A.
Venue
Allergy
Publisher
Wiley
Published
1999-05
Volume
54
Issue
5
Pages
484-488
ISSN
  • 0105-4538 (ISSN-L)
  • 1398-9995
OpenAlex
W2167345632
Cited by
81
References
4
FWCI
4.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effect of air filtration on airborne dog allergen. https://app.cochat.ai/papers/10.1034/j.1398-9995.1999.00029.x
The paper
Green, R., Simpson, A., Custovic, A., Faragher, B., Chapman, M., & Woodcock, A. (1999). The effect of air filtration on airborne dog allergen. Allergy. https://doi.org/10.1034/j.1398-9995.1999.00029.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.