Expiratory flow limitation in awake sleep-disordered breathing subjects
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Increased upper airways (UA) collapsibility has been implicated in the pathogeny of sleep-disordered breathing (SDB). An increased UA instability during expiration has recently been shown in healthy subjects. The present study assessed UA collapsibility in SDB patients by applying negative pressure during expiration. Full-night polysomnography was performed in 16 subjects (all snorers) with a wide range of SDB, and in six healthy control subjects. Physical examination, spirometry, and maximal inspiratory and expiratory flow rates were within normal limits for all 22 subjects. Negative expiratory pressure (NEP) (-5 cmH2O) was applied during quiet breathing in seated and supine position. Flow limitation (FL) during NEP was expressed as the percentage of tidal volume during which expiratory flow was less than or equal to the flow recorded during quiet breathing (%FL). The mean desaturation index (DI) of the 16 subjects was 27.3+/-26.4 (+/-sD) and the average FL in supine position was 38.4+/-37.9%. A close correlation between %FL supine during wakefulness and DI during sleep (r=0.84, p<0.001) was found. All obstructive sleep apnoea subjects had >30%FL supine. There was no FL in the six control subjects. In conclusion, negative expiratory pressure application during expiration appears to be a useful, noninvasive method for the evaluation of subjects with sleep-disordered breathing. Present results suggest that upper airway collapsibility can be detected in these subjects during wakefulness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Horner, R. L., Innes, J. A., Murphy, K., & Guz, A. (1991) · The Journal of Physiology · doi:10.1113/jphysiol.1991.sp018536 · Cited by 291
Activation of upper airway muscles before onset of inspiration in normal humans
Strohl, K. P., Hensley, M. J., Hallett, M., Saunders, N. A., & Ingram, R. H. (1980) · Journal of Applied Physiology · doi:10.1152/jappl.1980.49.4.638 · Cited by 231
Yildirim, N., Fitzpatrick, M. F., Whyte, K. F., Jalleh, R., Wightman, A. J. A., & Douglas, N. J. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.4.845 · Cited by 172
Cited by
Flow limitation and dynamic hyperinflation: key concepts in modern respiratory physiology
Calverley, P. M. A., & Koulouris, N. G. (2005) · European Respiratory Journal · doi:10.1183/09031936.04.00113204 · Cited by 258
“Turning this apparent drawback into an advantage, LIISTRO et al. [ 35 ] and VERIN et al. [36], in OSAHS patients with no evidence of intra-thoracic obstruction, found a significant correlation of the degree of flow limitation, expressed as % tidal volume in the supine position, with desaturation index and apnoea/hypop…”
Respiratory mechanics during exercise in endurance‐trained men and women
Guenette, J. A., Witt, J. D., McKenzie, D. C., Road, J. D., & Sheel, A. W. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.126466 · Cited by 247
Metadata
- Authors
- Liistro, G., Veriter, C., Dury, M., Aubert, G., & Stanescu, D.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1999-07
- Volume
- 14
- Issue
- 1
- Pages
- 185
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2157892038
- Cited by
- 52
- References
- 3
- FWCI
- 0.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Expiratory flow limitation in awake sleep-disordered breathing subjects. https://app.cochat.ai/papers/10.1034/j.1399-3003.1999.14a31.x
- The paper
- Liistro, G., Veriter, C., Dury, M., Aubert, G., & Stanescu, D. (1999). Expiratory flow limitation in awake sleep-disordered breathing subjects. European Respiratory Journal. https://doi.org/10.1034/j.1399-3003.1999.14a31.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.