Transcranial magnetic stimulation induces ‘pseudoabsence seizure’
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Objective: Several studies support the hypothesis of an antidepressive or mood‐enhancing effect of repetitive transcranial magnetic stimulation (rTMS) on depressive patients. The most acute concern regarding rTMS is possible seizure induction; therefore reports on seizure during rTMS are of special significance. Method: We describe a case in which high frequency rTMS over the left dorsolatero‐prefrontal cortex (DLPC) applied as an add‐on antidepressive strategy may have induced a frontal lobe complex partial seizure in a female patient affected by drug‐resistant depression. Results: The epileptic seizure was self‐limited, and the patient did not report any physical sequelae. The psychopathological improvement, observed immediately after the incident in question, did not last. Conclusion: We assume that in this case train duration in rTMS, combined with drugs modulating the norepinephrine turnover, may have contributed to the occurrence of this complex partial seizure, which neuroanatomically seems to be localized in the DLPC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Formula Method for Stimulus Setting in Bilateral Electroconvulsive Therapy: Relevance of Age
Gangadhar, B. N., Girish, K., Janakiramiah, N., Subbakrishna, D. K., Parameshwara, G., & Prasad, K. M. R. (1998) · The Journal of ECT · doi:10.1097/00124509-199812000-00008 · Cited by 23 · cited 1×
“The risk of seizure induction is related to the combination of various rTMS-parameters (magnetic intensity, pulse frequency, train duration and intertrain interval) which contribute to the spreading of neuronal excitation (2, 3).”
Background
Cited by
Rossi, S., Hallett, M., Rossini, P. M., & Pascual-Leone, A. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.08.016 · Cited by 5,367
“Conca et al. (2000) reported a seizure in a patient with major depression in whom rTMS (110% of MT, 20 Hz, train duration 5 s) was being used as an add-on treatment (Conca et al., 2000).”
MethodSafety of Intraoperative Transcranial Electrical Stimulation Motor Evoked Potential Monitoring
MacDonald, D. B. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200210000-00005 · Cited by 342
Lisanby, S. H., Luber, B., Schlaepfer, T. E., & Sackeim, H. A. (2003) · Neuropsychopharmacology · doi:10.1038/sj.npp.1300229 · Cited by 278
Loo, C. K., McFarquhar, T. F., & Mitchell, P. B. (2008) · International Journal of Neuropsychopharmacology · doi:10.1017/s1461145707007717 · Cited by 264
Safety of rTMS to non-motor cortical areas in healthy participants and patients
Machii, K., Cohen, D., Ramos-Estebanez, C., & Pascual-Leone, A. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.10.014 · Cited by 261
Metadata
- Authors
- Conca, A., König, P., & Hausmann, A.
- Venue
- Acta Psychiatrica Scandinavica
- Publisher
- Wiley
- Published
- 2000-03
- Volume
- 101
- Issue
- 3
- Pages
- 246-249
- ISSN
- 0001-690X (ISSN-L)
- 1600-0447
- OpenAlex
- W2022803129
- Cited by
- 45
- References
- 1
- FWCI
- 2.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transcranial magnetic stimulation induces ‘pseudoabsence seizure’. https://app.cochat.ai/papers/10.1034/j.1600-0447.2000.101003246.x
- The paper
- Conca, A., König, P., & Hausmann, A. (2000). Transcranial magnetic stimulation induces ‘pseudoabsence seizure’. Acta Psychiatrica Scandinavica. https://doi.org/10.1034/j.1600-0447.2000.101003246.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.