The DOI matches its Crossref record.
Threshold of tactile sensitivity perceived with dental endosseous implants and natural teeth
Abstract
The aim of this study was to determine the threshold of tactile perception of endosseous dental implants and to assess the relative difference of that threshold between implants and teeth. Twenty‐two subjects with implants of the ITI® Dental Implant System were included in the study. All implants served as abutments for single tooth crowns and had been in function for a minimum of 1 year. A strain gauge glued to the shaft of an amalgam plugger served as a force sensor. It transformed the elastic deformation exerted onto the shaft into an electronic signal for recording. By use of the amalgam plugger, a continuously increasing force was exercised on the implants or teeth until the first sensation of touch was indicated by the patient. Statistical analysis revealed threshold values for the implants ranging from 13.2 to 189.4g (1g=0.0lN)(mean 100.6; SD 47.7), while a range of 1.2 to 26.2g (mean 11.5; SD 11.5) was found for control teeth. Thus, the mean threshold values for implants were 8.75 times higher than for teeth. This difference was highly statistically significant. A general linear models procedure was applied to determine the influence of patient age, jaw, implant position and the threshold values of teeth on the measurements obtained for implants. Only gender and the threshold values for contralateral teeth had a significant influence. These 2 parameters together explained 27% of the variability in threshold measurements. It is concluded that a more than 8‐fold higher threshold value for tactile perception exists for implants compared with teeth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tan, K., Pjetursson, B. E., Lang, N. P., & Chan, E. S. Y. (2004) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2004.01119.x · Cited by 769
Self-citationFully functional bioengineered tooth replacement as an organ replacement therapy
Ikeda, E., Morita, R., Nakao, K., Ishida, K., Nakamura, T., Takano-Yamamoto, T., Ogawa, M., Mizuno, M., Kasugai, S., & Tsuji, T. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0902944106 · Cited by 447
Brägger, U., Aeschlimann, S., Bürgin, W., Hämmerle, C. H. F., & Lang, N. P. (2001) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2001.012001026.x · Cited by 395
Self-citationLang, N. P., Pjetursson, B. E., Tan, K., Brägger, U., Egger, M., & Zwahlen, M. (2004) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2004.01118.x · Cited by 359
Self-citationProsthetic failures in dental implant therapy
Sailer, I., Karasan, D., Todorovic, A., Ligoutsikou, M., & Pjetursson, B. E. (2022) · Periodontology 2000 · doi:10.1111/prd.12416 · Cited by 278
Metadata
- Authors
- Hämmerle, C. H. F., Wagner, D., Brägger, U., Lussi, A., Karayiannis, A., Joss, A., & Lang, N. P.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 1995-06
- Volume
- 6
- Issue
- 2
- Pages
- 83-90
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W1973469591
- Cited by
- 195
- References
- 0
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Threshold of tactile sensitivity perceived with dental endosseous implants and natural teeth. https://app.cochat.ai/papers/10.1034/j.1600-0501.1995.060203.x
- The paper
- Hämmerle, C. H. F., Wagner, D., Brägger, U., Lussi, A., Karayiannis, A., Joss, A., & Lang, N. P. (1995). Threshold of tactile sensitivity perceived with dental endosseous implants and natural teeth. Clinical Oral Implants Research. https://doi.org/10.1034/j.1600-0501.1995.060203.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.