Red blood cell and platelet interactions with titanium implant surfaces
The DOI matches its Crossref record.
Abstract
The influence of the micro‐roughened surface, produced by dual acid‐etching (DAE) of machined commercially pure titanium, on initial blood cell/implant interactions was investigated by observing the blood components remaining at the implant surface following freeze‐fracture of clotted, and fixed, human blood. Glass surfaces were also used for immuno‐labelling studies to identify fibrin and platelets. The interface comprised predominantly fibrin and red blood cells (RBCs). The difference in distribution of RBCs was statistically significant (P<0.05) at 10 min of blood/implant contact, but diminished thereafter. Micro‐roughened DAE implant surfaces showed, qualitatively, more platelets than machined surfaces, while the textured glass surfaces demonstrated increased platelet aggregation. We believe that these early blood cell/implant interactions may play a key role in the osteoconduction stage of peri‐implant bone healing response to micro‐roughened implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Surface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406
Understanding Peri‐Implant Endosseous Healing
Davies, J. E. (2003) · Journal of Dental Education · doi:10.1002/j.0022-0337.2003.67.8.tb03681.x · Cited by 1,063
Self-citationHigh surface energy enhances cell response to titanium substrate microstructure
Zhao, G., Schwartz, Z., Wieland, M., Rupp, F., Geis‐Gerstorfer, J., Cochran, D. L., & Boyan, B. D. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30320 · Cited by 922
Surface Modifications and Their Effects on Titanium Dental Implants
Jemat, A., Ghazali, M. J., Razali, M., & Otsuka, Y. (2015) · BioMed Research International · doi:10.1155/2015/791725 · Cited by 611
Osseointegration and current interpretations of the bone-implant interface
Shah, F. A., Thomsen, P., & Palmquist, A. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.11.018 · Cited by 381
Kazemzadeh-Narbat, M., Lai, B. F. L., Ding, C., Kizhakkedathu, J. N., Hancock, R. E. W., & Wang, R. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.04.036 · Cited by 361
Tambasco de Oliveira, P., & Nanci, A. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00539-8 · Cited by 360
Roughness induced dynamic changes of wettability of acid etched titanium implant modifications
Rupp, F., Scheideler, L., Rehbein, D., Axmann, D., & Geis-Gerstorfer, J. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.015 · Cited by 355
Peri-implant osteogenesis in health and osteoporosis
Marco, F., Milena, F., Gianluca, G., & Vittoria, O. (2005) · Micron · doi:10.1016/j.micron.2005.07.008 · Cited by 304
A Brief Historical Perspective on Dental Implants, Their Surface Coatings and Treatments
Abraham, C. M. (2014) · The Open Dentistry Journal · doi:10.2174/1874210601408010050 · Cited by 298
Platelet interactions with titanium: modulation of platelet activity by surface topography
Park, J. Y., Gemmell, C. H., & Davies, J. E. (2001) · Biomaterials · doi:10.1016/s0142-9612(01)00009-6 · Cited by 297
Self-citationRefai, A. K., Textor, M., Brunette, D. M., & Waterfield, J. D. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30075 · Cited by 296
Implant surface characteristics and their effect on osseointegration
Barfeie, A., Wilson, J., & Rees, J. (2015) · British Dental Journal · doi:10.1038/sj.bdj.2015.171 · Cited by 292
Role of implants surface modification in osseointegration: A systematic review
Liu, Y., Rath, B., Tingart, M., & Eschweiler, J. (2020) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36829 · Cited by 287
Titanium–Tissue Interface Reaction and Its Control With Surface Treatment
Hanawa, T. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00170 · Cited by 284
Rocci, A., Martignoni, M., & Gottlow, J. (2003) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2003.tb00016.x · Cited by 268
Nanoscale surface modifications of medically relevant metals: state-of-the art and perspectives
Variola, F., Brunski, J. B., Orsini, G., Tambasco de Oliveira, P., Wazen, R., & Nanci, A. (2011) · Nanoscale · doi:10.1039/c0nr00485e · Cited by 260
Titanium oral implants: surface characteristics, interface biology and clinical outcome
Palmquist, A., Omar, O. M., Esposito, M., Lausmaa, J., & Thomsen, P. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0118.focus · Cited by 258
Short-Term and Long-Term Effects of Orthopedic Biodegradable Implants
Amini, A. R., Wallace, J. S., & Nukavarapu, S. P. (2011) · Journal of Long-Term Effects of Medical Implants · doi:10.1615/jlongtermeffmedimplants.v21.i2.10 · Cited by 181
Luo, J., Walker, M., Xiao, Y., Donnelly, H., Dalby, M. J., & Salmeron-Sanchez, M. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.11.024 · Cited by 164
“…the biological environment occurs as soon as the implant is introduced, the implant surface plays an important role in influencing the sequence of initial protein adsorption, interactions with blood such as platelet adhesion and haemostasis, inflammation, and osteogenic cell responses [15 – 24].”
BackgroundHealth, Maintenance, and Recovery of Soft Tissues around Implants
Wang, Y., Zhang, Y., & Miron, R. J. (2016) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12343 · Cited by 161
Metadata
- Authors
- Park, J. Y., & Davies, J. E.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2000-12
- Volume
- 11
- Issue
- 6
- Pages
- 530-539
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W2016576220
- Cited by
- 299
- References
- 0
- FWCI
- 8.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.