The DOI matches its Crossref record.
Histologic evaluation of the bone integration of TiO2 blasted and turned titanium microimplants in humans
Abstract
Abstract: Twenty‐seven patients received 2 microimplants each during implant surgery. One microimplant was blasted with 25 μm sized particles of TiO 2; the other was left as machined i.e. a turned surface. Before insertion the surface topography was characterized with an optical confocal laser profilometer. The surface roughness was greater than standard implants, and was similar for both surface modifications averaging over all parts of the implant i.e. tops, valley and flanks. The mean surface roughness from flank measurements only replicated previously reported findings: i.e. significantly rougher surfaces on blasted implants. After a mean healing period of 6.3 months in the maxillae and 3.9 months in the mandible, the microimplants and surrounding tissue were removed with a trephine burr. The histomorphometrical evaluation demonstrated significantly higher bone‐to‐implant contact for the blasted implants, inserted in the maxilla or in the mandible. Significantly more bone was found inside the threaded area for the blasted implants in the mandible, but there was no difference for implants positioned in maxillae.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Surface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406
Bosshardt, D. D., Chappuis, V., & Buser, D. (2017) · Periodontology 2000 · doi:10.1111/prd.12179 · Cited by 574
Implant surface characteristics and their effect on osseointegration
Barfeie, A., Wilson, J., & Rees, J. (2015) · British Dental Journal · doi:10.1038/sj.bdj.2015.171 · Cited by 292
Tan, K. S., Qian, L., Rosado, R., Flood, P. M., & Cooper, L. F. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.05.002 · Cited by 163
Surface-modified titanium to enhance osseointegration in dental implants
SARINNAPHAKORN, L., & DI SILVIO, L. (2009) · Cellular Response to Biomaterials · doi:10.1533/9781845695477.3.572 · Cited by 4
Metadata
- Authors
- Ivanoff, C., Widmark, G., Hallgren, C., Sennerby, L., & Wennerberg, A.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2001-04
- Volume
- 12
- Issue
- 2
- Pages
- 128-134
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W2069329114
- Cited by
- 195
- References
- 0
- FWCI
- 7.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Histologic evaluation of the bone integration of TiO2 blasted and turned titanium microimplants in humans. https://app.cochat.ai/papers/10.1034/j.1600-0501.2001.012002128.x
- The paper
- Ivanoff, C., Widmark, G., Hallgren, C., Sennerby, L., & Wennerberg, A. (2001). Histologic evaluation of the bone integration of TiO2 blasted and turned titanium microimplants in humans. Clinical Oral Implants Research. https://doi.org/10.1034/j.1600-0501.2001.012002128.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.