The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Chemistry in indoor environments: 20 years of research
Open accessAbstract
UNLABELLED: In the two decades since the first issue of Indoor Air, there have been over 250 peer-reviewed publications addressing chemical reactions among indoor pollutants. The present review has assembled and categorized these publications. It begins with a brief account of the state of our knowledge in 1991 regarding 'indoor chemistry', much of which came from corrosion and art conservation studies. It then outlines what we have learned in the period between 1991 and 2010 in the context of the major reference categories: gas-phase chemistry, surface chemistry, health effects and reviews/workshops. The indoor reactions that have received the greatest attention are those involving ozone-with terpenoids in the gas-phase as well as with the surfaces of common materials, furnishings, and the occupants themselves. It has become clear that surface reactions often have a larger impact on indoor settings than do gas-phase processes. This review concludes with a subjective list of major research needs going forward, including more information on the decomposition of common indoor pollutants, better understanding of how sorbed water influences surface reactions, and further identification of short-lived products of indoor chemistry. Arguably, the greatest need is for increased knowledge regarding the impact that indoor chemistry has on the health and comfort of building occupants. PRACTICAL IMPLICATIONS: Indoor chemistry changes the type and concentration of chemicals present in indoor environments. In the past, products of indoor chemistry were often overlooked, reflecting a focus on stable, relatively non-polar organic compounds coupled with the use of sampling and analytical methods that were unable to 'see' many of the products of such chemistry. Today, researchers who study indoor environments are more aware of the potential for chemistry to occur. Awareness is valuable, because it leads to the use of sampling methods and analytical tools that can detect changes in indoor environments resulting from chemical processes. This, in turn, leads to a more complete understanding of occupants' chemical exposures, potential links between these exposures and adverse health effects and, finally, steps that might be taken to mitigate these adverse effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evolution of Organic Aerosols in the Atmosphere
Jimenez, J. L., Canagaratna, M. R., Donahue, N. M., Prevot, A. S. H., Zhang, Q., Kroll, J. H., DeCarlo, P. F., Allan, J. D., Coe, H., Ng, N. L., et al. (2009) · Science · doi:10.1126/science.1180353 · Cited by 4,167
Formaldehyde in the Indoor Environment
Salthammer, T., Mentese, S., & Marutzky, R. (2010) · Chemical Reviews · doi:10.1021/cr800399g · Cited by 1,808
Sleiman, M., Gundel, L. A., Pankow, J. F., Jacob, P., Singer, B. C., & Destaillats, H. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0912820107 · Cited by 427
Indoor secondary pollutants from cleaning product and air freshener use in the presence of ozone
Singer, B. C., Coleman, B. K., Destaillats, H., Hodgson, A. T., Lunden, M. M., Weschler, C. J., & Nazaroff, W. W. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.06.005 · Cited by 330
Self-citationThe transformation of outdoor ammonium nitrate aerosols in the indoor environment
Lunden, M. M., Revzan, K. L., Fischer, M. L., Thatcher, T. L., Littlejohn, D., Hering, S. V., & Brown, N. J. (2003) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.09.035 · Cited by 152
Cited by
Pöschl, U., & Shiraiwa, M. (2015) · Chemical Reviews · doi:10.1021/cr500487s · Cited by 657
Li, Y., Pöschl, U., & Shiraiwa, M. (2016) · Atmospheric Chemistry and Physics · doi:10.5194/acp-16-3327-2016 · Cited by 384
Lakey, P. S. J., Berkemeier, T., Tong, H., Arangio, A. M., Lucas, K., Pöschl, U., & Shiraiwa, M. (2016) · Scientific Reports · doi:10.1038/srep32916 · Cited by 365
Volatile organic compounds in fourteen U.S. retail stores
Nirlo, E. L., Crain, N., Corsi, R. L., & Siegel, J. A. (2014) · Indoor Air · doi:10.1111/ina.12101 · Cited by 30
Metadata
- Authors
- Weschler, C. J.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2011-04-18
- Volume
- 21
- Issue
- 3
- Pages
- 205-218
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2109337693
- Cited by
- 206
- References
- 5
- FWCI
- 9.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chemistry in indoor environments: 20 years of research. https://app.cochat.ai/papers/10.1111/j.1600-0668.2011.00713.x
- The paper
- Weschler, C. J. (2011). Chemistry in indoor environments: 20 years of research. Indoor Air. https://doi.org/10.1111/j.1600-0668.2011.00713.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.