The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The effect of structures on indoor humidity - possibility to improve comfort and perceived air quality: Effect of structures on indoor humidity
Open accessAbstract
The research presented in this paper shows that moisture transfer between indoor air and hygroscopic building structures can generally improve indoor humidity conditions. This is important because the literature shows that indoor humidity has a significant effect on occupant comfort, perceived air quality (PAQ), occupant health, building durability, material emissions, and energy consumption. Therefore, it appears possible to improve the quality of life of occupants when appropriately applying hygroscopic wood-based materials. The paper concentrates on the numerical investigation of a bedroom in a wooden building located in four European countries (Finland, Belgium, Germany, and Italy). The results show that moisture transfer between indoor air and the hygroscopic structure significantly reduces the peak indoor humidity. Based on correlations from the literature, which quantify the effect of temperature and humidity on comfort and PAQ for sedentary adults, hygroscopic structures can improve indoor comfort and air quality. In all the investigated climates, it is possible to improve the indoor conditions such that, as many as 10 more people of 100 are satisfied with the thermal comfort conditions (warm respiratory comfort) at the end of occupation. Similarly, the percent dissatisfied with PAQ can be 25% lower in the morning when permeable and hygroscopic structures are applied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Cited by
Al horr, Y., Arif, M., Katafygiotou, M., Mazroei, A., Kaushik, A., & Elsarrag, E. (2016) · International Journal of Sustainable Built Environment · doi:10.1016/j.ijsbe.2016.03.006 · Cited by 817
The Ecology of Building Materials
Berge, B. (2009) · Routledge eBooks · doi:10.4324/9780080949741 · Cited by 362
Performance evaluation of indirect evaporative cooling using whole-building hygrothermal simulations
Steeman, M., Janssens, A., & De Paepe, M. (2009) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2009.02.004 · Cited by 38
Metadata
- Authors
- Simonson, C. J., Salonvaara, M., & Ojanen, T.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2002-12
- Volume
- 12
- Issue
- 4
- Pages
- 243-251
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2036129751
- Cited by
- 168
- References
- 1
- FWCI
- 9.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The effect of structures on indoor humidity - possibility to improve comfort and perceived air quality: Effect of structures on indoor humidity. https://app.cochat.ai/papers/10.1034/j.1600-0668.2002.01128.x
- The paper
- Simonson, C. J., Salonvaara, M., & Ojanen, T. (2002). The effect of structures on indoor humidity - possibility to improve comfort and perceived air quality: Effect of structures on indoor humidity. Indoor Air. https://doi.org/10.1034/j.1600-0668.2002.01128.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.