Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 242

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Performance and costs of particle air filtration technologies: Air filtration technology

Fisk, W. J., Faulkner, D., Palonen, J., Seppanen, O. · 2002 · Indoor Air

Abstract

This paper predicts the reductions in the indoor mass concentrations of particles attainable from use of filters in building supply airstreams and also from use of stand-alone fan-filter units. Filters with a wide efficiency range are considered. Predicted concentration reductions are provided for indoor-generated particles containing dust-mite and cat allergen, for environmental tobacco smoke (ETS) particles, and for outdoor air fine-mode particles. Additionally, this paper uses a simple model and available data to estimate the energy and total costs of the filtration options. Predicted reductions in cat and dust-mite allergen concentrations range from 20 to 80%. To obtain substantial, e.g. 50%, reductions in indoor concentrations of these allergens, the rate of airflow through the filter must be at least a few indoor volumes per hour. Increasing filter efficiencies above approximately ASHRAE Dust Spot 65% does not significantly reduce predicted indoor concentrations of these allergens. For ETS particles and outdoor fine-mode particles, calculations indicate that relatively large, e.g. 80%, decreases in indoor concentrations are attainable with practical filter efficiencies and flow rates. Increasing the filter efficiency above ASHRAE 85% results in only modest predicted incremental decreases in indoor concentration. Energy costs and total costs can be similar for filtration using filters with a wide range of efficiency ratings. Total estimated filtration costs of approximately $0.70 to $1.80 per person per month are insignificant relative to salaries, rent, or health insurance costs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1034/j.1600-0668.2002.01136.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 242

Metadata

Authors
Fisk, W. J., Faulkner, D., Palonen, J., & Seppanen, O.
Venue
Indoor Air
Published
2002-12
Volume
12
Issue
4
Pages
223-234
ISSN
0905-6947 (ISSN-L)
OpenAlex
W2059596684
Cited by
242
References
3
FWCI
4.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance and costs of particle air filtration technologies: Air filtration technology. https://app.cochat.ai/papers/10.1034/j.1600-0668.2002.01136.x
The paper
Fisk, W. J., Faulkner, D., Palonen, J., & Seppanen, O. (2002). Performance and costs of particle air filtration technologies: Air filtration technology. Indoor Air. https://doi.org/10.1034/j.1600-0668.2002.01136.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.