The DOI matches its Crossref record.
Physical and physiological effects of stratum corneum tape stripping
Abstract
Background/aims: Tape stripping of human stratum corneum has been performed to measure stratum corneum mass, barrier function, drug reservoir and percutaneous penetration. However, the technique itself requires further development to facilitate interpretation. Methods: In this study we quantified stratum corneum (SC) tape stripping and water kinetic parameters utilizing three types of adhesive tapes, in an in vivo randomized clinical trial. Stratum corneum was tape stripped, and the mass of SC removed by each tape was quantified utilizing a protein assay. Transepidermal water loss (TEWL) was measured and barrier disruption and SC water kinetics calculated. Three commonly utilized acrylate adhesive tapes were utilized and a comparison made between them. Results: Each type of tape successfully stripped the stratum corneum, but the rayon tape did not induce SC barrier disruption. Neither the type of tape nor the site stripped significantly influenced the mass of SC removed. Water kinetic parameters did not differ significantly for the tapes that did induce barrier disruption. Individual variation in barrier disruption to water following tape stripping was demonstrated. Conclusion: The tapes utilized removed a similar amount of SC. The tapes have a different propensity to cause barrier disruption. Some individuals do not demonstrate increased TEWL despite an equivalent mass of SC being removed compared to those who do show a response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Novel mechanisms and devices to enable successful transdermal drug delivery
Barry, B. W. (2001) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(01)00167-1 · Cited by 1,240
Lipid nanoparticles for improved topical application of drugs for skin diseases☆
SCHAFERKORTING, M., MEHNERT, W., & KORTING, H. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.04.006 · Cited by 614
Micro-scale devices for transdermal drug delivery
Arora, A., Prausnitz, M. R., & Mitragotri, S. (2008) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2008.08.032 · Cited by 464
Research Techniques Made Simple: Transepidermal Water Loss Measurement as a Research Tool
Alexander, H., Brown, S., Danby, S., & Flohr, C. (2018) · Journal of Investigative Dermatology · doi:10.1016/j.jid.2018.09.001 · Cited by 288
Role for inner ring deiodination preventing transcutaneous passage of thyroxine
Santini, F., Vitti, P., Chiovato, L., Ceccarini, G., Macchia, M., Montanelli, L., Gatti, G., Rosellini, V., Mammoli, C., Martino, E., et al. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2002-021439 · Cited by 37
Metadata
- Authors
- Bashir, S. J., Chew, A., Anigbogu, A., Dreher, F., & Maibach, H. I.
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 2001-02
- Volume
- 7
- Issue
- 1
- Pages
- 40-48
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W1983079125
- Cited by
- 213
- References
- 0
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physical and physiological effects of stratum corneum tape stripping. https://app.cochat.ai/papers/10.1034/j.1600-0846.2001.007001040.x
- The paper
- Bashir, S. J., Chew, A., Anigbogu, A., Dreher, F., & Maibach, H. I. (2001). Physical and physiological effects of stratum corneum tape stripping. Skin Research and Technology. https://doi.org/10.1034/j.1600-0846.2001.007001040.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.