Direct observation of single kinesin molecules moving along microtubules
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Kinesin is a two-headed motor protein that powers organelle transport along microtubules. Many ATP molecules are hydrolysed by kinesin for each diffusional encounter with the microtubule. Here we report the development of a new assay in which the processive movement of individual fluorescently labelled kinesin molecules along a microtubule can be visualized directly; this observation is achieved by low-background total internal reflection fluorescence microscopy in the absence of attachment of the motor to a cargo (for example, an organelle or bead). The average distance travelled after a binding encounter with a microtubule is 600 nm, which reflects a approximately 1% probability of detachment per mechanical cycle. Surprisingly, processive movement could still be observed at salt concentrations as high as 0.3 M NaCl. Truncated kinesin molecules having only a single motor domain do not show detectable processive movement, which is consistent with a model in which kinesin's two force-generating heads operate by a hand-over-hand mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Processive movements have been reported for kinesin-1 (20 -23) and some other kinesin-related proteins”
From Diffusion and Directed Movement (2008) · cites this paper as [21]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Identification of a novel force-generating protein, kinesin, involved in microtubule-based motility
VALE, R., REESE, T., & SHEETZ, M. (1985) · Cell · doi:10.1016/s0092-8674(85)80099-4 · Cited by 1,993
Self-citationDirect observation of kinesin stepping by optical trapping interferometry
Svoboda, K., Schmidt, C. F., Schnapp, B. J., & Block, S. M. (1993) · Nature · doi:10.1038/365721a0 · Cited by 1,910
Funatsu, T., Harada, Y., Tokunaga, M., Saito, K., & Yanagida, T. (1995) · Nature · doi:10.1038/374555a0 · Cited by 1,047
Self-citationBead movement by single kinesin molecules studied with optical tweezers
Block, S. M., Goldstein, L. S. B., & Schnapp, B. J. (1990) · Nature · doi:10.1038/348348a0 · Cited by 1,038
Mechanochemical coupling in actomyosin energy transduction studied by in vitro movement assay
Harada, Y., Sakurada, K., Aoki, T., Thomas, D. D., & Yanagida, T. (1990) · Journal of Molecular Biology · doi:10.1016/s0022-2836(05)80060-9 · Cited by 522
Self-citationHirokawa, N., Pfister, K. K., Yorifuji, H., Wagner, M. C., Brady, S. T., & Bloom, G. S. (1989) · Cell · doi:10.1016/0092-8674(89)90691-0 · Cited by 477
Yang, J. T., Laymon, R. A., & Goldstein, L. S. B. (1989) · Cell · doi:10.1016/0092-8674(89)90692-2 · Cited by 397
Evidence for alternating head catalysis by kinesin during microtubule-stimulated ATP hydrolysis.
Hackney, D. D. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.15.6865 · Cited by 351
Pathway of processive ATP hydrolysis by kinesin
Gilbert, S. P., Webb, M. R., Brune, M., & Johnson, K. A. (1995) · Nature · doi:10.1038/373671a0 · Cited by 252
Two types of Chlamydomonas flagellar mutants missing different components of inner-arm dynein.
Kamiya, R., Kurimoto, E., & Muto, E. (1991) · The Journal of cell biology · doi:10.1083/jcb.112.3.441 · Cited by 219
Research works printed but not linked: 2
- Bloom, G. & Endow, S. Motor Proteins 1: Kinesin (Academic, London, 1994).
- Hyman, A. et al. Meth. Enzym. 196, 303–319 (1990).
Cited by
Items 501–600 of 708
‘Mitotic’ kinesin-5 is a dynamic brake for axonal growth in Drosophila
Lü, W., Lee, B. S., Deng, H. X. Y., Lakonishok, M., Martín-Blanco, E., & Gelfand, V. I. (2025) · Development · doi:10.1242/dev.204424 · Cited by 7
Portran, D. (2014) · Methods in cell biology · doi:10.1016/b978-0-12-417136-7.00003-3 · Cited by 5
“The use of PEG-based surface treatment offers great advantages over non-covalent blocking methods, such as BSA (Vale et al., 1996) or casein (Howard, Hunt, & Baek, 1993), which may not achieve sufficient passivation.”
MethodInfluentialTaba, T., Edamatsu, M., Toba, S., Shibata, K., Imafuku, Y., Toyoshima, Y. Y., Tawada, K., & Yamada, A. (2008) · Cell Motility and the Cytoskeleton · doi:10.1002/cm.20303 · Cited by 5
“It has been reported that shortening or deleting the neck helix greatly reduces the gliding speed of microtubules on glass surfaces [Stewart et al., 1993; Berliner et al., 1995; Vale et al., 1996].”
BackgroundA Markovian engine for a biological energy transducer: The catalytic wheel
Tsong, T. Y., & Chang, C.-H. (2006) · Biosystems · doi:10.1016/j.biosystems.2006.08.014 · Cited by 5
Fluorescence Imaging with One Nanometer Accuracy
Selvin, P. R., Syed, R., & Sobh, N. (2011) · doi:10.4231/d3696zx7f · Cited by 5
Theoretical Analysis of Kinesin KIF1A Transport Along Microtubule
Zhang, Y. (2013) · Journal of Statistical Physics · doi:10.1007/s10955-013-0804-y · Cited by 5
Verhey, K. J., Cochran, J. C., & Walczak, C. (2015) · Springer eBooks · doi:10.1007/978-94-017-9732-0_1 · Cited by 6
Single-molecule DNA digestion in various alkanethiol-functionalized gold nanopores
Lee, S., & Kang, S. H. (2013) · Talanta · doi:10.1016/j.talanta.2013.01.046 · Cited by 5
Inami, W., & Kawata, Y. (2003) · Journal of Applied Physics · doi:10.1063/1.1593806 · Cited by 5
Protein‐based Nanotechnology: Kinesin–Microtubule‐driven Systems for Bioanalytical Applications
Hancock, W. O. (2003) · Wiley eBooks · doi:10.1002/9783527610419.ntls0042 · Cited by 5
Motility Assays for Microtubule Motor Proteins
Rogers, S. L., & Scholey, J. M. (2004) · Wiley eBooks · doi:10.1038/npg.els.0002621 · Cited by 6
Analysis of single-molecule kinesin assay data by hidden Markov model filtering
Walton, D. B. (2002) · UA Campus Repository (The University of Arizona) · Cited by 6
Parkes, M., Landers, N., & Gramlich, M. W. (2023) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2023.1286915 · Cited by 5
“MT motor motility (dynein/kinesin) is consistent in the faster SVs that traverse presynapses ( > 1.0 μ m/s, Figure 4L), (Vale et al., 1996; Hirokawa et al., 2009), whereas the actin-based molecular motor myosin V speed is consistent in slower SVs that are captured by presynapses ( < 1 μ m/s) (Baker…”
BackgroundInfluentialKita, T., & Niwa, S. (2024) · BIO-PROTOCOL · doi:10.21769/bioprotoc.5135 · Cited by 4
Kuznetsov, A. V. (2011) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2011.585977 · Cited by 4
“5 s(21) (Vale et al. 1996; Carter and Cross 2005), whereas the average detachment rate from MTs is estimated as 0.”
BackgroundInfluentialXie, X. S., & Lu, H. P. (2001) · Springer series in chemical physics · doi:10.1007/978-3-642-56544-1_13 · Cited by 4
Singh, S. K., Siegler, N., Pandey, H., Yanir, N., Popov, M., Goldstein-Levitin, A., Sadan, M., Debs, G. E., Zarivach, R., Frank, G. A., et al. (2024) · Science Advances · doi:10.1126/sciadv.adi1367 · Cited by 6
A model of axonal transport drug delivery
Kuznetsov, A. V. (2011) · Open Physics · doi:10.2478/s11534-011-0116-2 · Cited by 4
Effects of dynein inhibitor on the number of motor proteins transporting synaptic cargos
Hayashi, K., Miyamoto, M. G., & Niwa, S. (2021) · Biophysical Journal · doi:10.1016/j.bpj.2021.02.018 · Cited by 4
Design of Active Nanosystems Incorporating Biomolecular Motors
Tsitkov, S., & Hess, H. (2021) · Wiley eBooks · doi:10.1002/9783527821990.ch13 · Cited by 4
Mensi, M., Dukenbayev, K., Sekatskii, S. K., & Dietler, G. (2009) · Laser Physics · doi:10.1134/s1054660x09170125 · Cited by 4
Tsujibayashi, T., Ichimiya, M., Toyoda, K., & Ohno, N. (2011) · Japanese Journal of Applied Physics · doi:10.1143/jjap.50.101601 · Cited by 4
Ishii, Y., Kozuka, J., Esaki, S., & Yanagida, T. (2008) · IEEE International Conference on Systems, Man and Cybernetics · doi:10.1007/978-1-4020-4465-6_24 · Cited by 2
Self-citationDispersive one-dimensional (Mo/Si) nanocrystals for single molecular detection systems using x rays
Okumura, Y., Taniguchi, Y., & Sasaki, Y. C. (2002) · Journal of Applied Physics · doi:10.1063/1.1520721 · Cited by 4
Wang, T., Isoshima, T., Miyawaki, A., & Hara, M. (2006) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2006.03.032 · Cited by 4
Modelling active transport in Drosophila unipolar motor neurons
Kuznetsov, A. V. (2011) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2010.515983 · Cited by 4
“The average detachment rate from MTs for cytoplasmic dynein ~k 0 2 is estimated as 0.25 s21 (King and Schroer 2000; Reck-Peterson et al. 2006), while that for kinesin-1 ~k 0 þ it is estimated as 1 s21 (Vale et al. 1996; Schnitzer et al. 2000).”
BackgroundMethodInfluentialLerch, H.-P., Stange, P., Mikhailov, A. S., & Hess, B. (2002) · The Journal of Physical Chemistry B · doi:10.1021/jp0136314 · Cited by 4
Single-Molecule Detection and Manipulation
Balzer, B. N., & Hugel, T. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.01334-5 · Cited by 4
Mirzakhalili, E., Nam, W., & Epureanu, B. I. (2017) · Nonlinear Dynamics · doi:10.1007/s11071-017-3673-0 · Cited by 4
Total Internal Reflection Fluorescent Microscopy
Toomre, D. K., & Axelrod, D. (2006) · Elsevier eBooks · doi:10.1016/b978-012164730-8/50130-1 · Cited by 5
Fluorescence Tracking of Motor Proteins In Vitro
DeWitt, M. A., Schenkel, T., & Yıldız, A. (2014) · Proceedings of the Fourth International Symposium on Polarization Phenomena in Nuclear Reactions · doi:10.1007/978-3-0348-0856-9_10 · Cited by 4
“The use of TIR microscopy allowed detection of single fluorescently labeled motors in solution [8, 9].”
Talaga, D. S., Jia, Y., Bopp, M. A., Sytnik, A. I., DeGrado, W. F., Cogdell, R. J., & Hochstrasser, R. M. (2001) · Springer series in chemical physics · doi:10.1007/978-3-642-56544-1_18 · Cited by 4
Mechanics of Unconventional Myosins
Rock, R. S., Purcell, T. J., & Spudich, J. A. (2003) · The Enzymes · doi:10.1016/s1874-6047(04)80003-9 · Cited by 4
Imaging And Nano‐Manipulation Of Single Actomyosin Motors At Work
Ishii, Y., Kimura, Y., Kitamura, K., Tanaka, H., Wazawa, T., & Yanagida, T. (2000) · Clinical and Experimental Pharmacology and Physiology · doi:10.1046/j.1440-1681.2000.03226.x · Cited by 4
Self-citationNew trends in studying structure and function of biological membranes
Damjanovich, S., Vámosi, G., Bodnár, A., & Bene, L. (2002) · Acta Physiologica Hungarica · doi:10.1556/aphysiol.89.2002.4.2 · Cited by 4
Fluorescence Microscopy of Single Viral Capsids
Huang, S., Hayes, S. J., & Serwer, P. (2001) · Journal of Structural Biology · doi:10.1006/jsbi.2001.4412 · Cited by 4
Motoring down the highways of the cell
Trayer, I. P., & Smith, K. J. (1997) · Trends in Cell Biology · doi:10.1016/s0962-8924(97)01083-0 · Cited by 4
Endosome-ER Interactions Define a Cellular Energy Landscape to Guide Cargo TransportPreprint
Shen, Y., Wen, Y., Zhao, Q., Huang, P., Lai, P., & Tong, P. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.06.01.543348 · Cited by 4
The advantage of MINFLUX nanoscopy in single molecular tracking within living cells
Zou, H., Li, S., Kou, X., Gu, Z., & Wang, J. (2025) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545825300083 · Cited by 3
Single-Molecule and Single-Particle Imaging of Molecular Motors In Vitro and In Vivo
Fili, N. (2014) · Proceedings of the Fourth International Symposium on Polarization Phenomena in Nuclear Reactions · doi:10.1007/978-3-0348-0856-9_7 · Cited by 3
“Alternatively, the single-molecule format is based on tracking individual fluorescently labelled kinesins on surface-immobilised MTs [119–121].”
BackgroundFujimaki, M., Iwanabe, Y., Rockstuhl, C., Wang, X., Awazu, K., & Tominaga, J. (2007) · Japanese Journal of Applied Physics · doi:10.1143/jjap.46.l1080 · Cited by 3
Kuznetsov, A. V. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.03.009 · Cited by 3
“For kinesin-1 (conventional kinesin), the average attachment rate to MTs is estimated to be 5 s−1 [23,24] while the average detachment rate from MTs is estimated to be 1 s−1 [25,26].”
BackgroundKinesin Recycling in Stationary Membrane Tubes
Shaklee, P. M., Idema, T., Bourel‐Bonnet, L., Dogterom, M., & Schmidt, T. (2010) · Biophysical Journal · doi:10.1016/j.bpj.2010.06.071 · Cited by 3
Nam, W., & Epureanu, B. I. (2016) · PLoS ONE · doi:10.1371/journal.pone.0147676 · Cited by 4
Measuring Microtubule Growth and Gliding in Caenorhabditis elegans Embryos
Tegha-Dunghu, J., Gusnowski, E. M., & Srayko, M. (2014) · Methods in molecular biology · doi:10.1007/978-1-4939-0329-0_7 · Cited by 3
Reconstitution of microtubule-based motility using cell extracts
Ayloo, S., & Holzbaur, E. L. F. (2015) · Methods in cell biology · doi:10.1016/bs.mcb.2015.02.002 · Cited by 4
A Bayesian Framework for the Analog Reconstruction of Kymographs From Fluorescence Microscopy Data
Samuylov, D. K., Székely, G. J., & Paul, G. (2018) · IEEE Transactions on Image Processing · doi:10.1109/tip.2018.2867946 · Cited by 4
“[41]).”
A spatially specified systems pharmacology therapy for axonal recovery after injury
Siddiq, M. M., Johnson, N. P., Zorina, Y., Yadaw, A. S., Toro, C. A., Hansen, J., Rabinovich, V., Gregorich, S. M., Xiong, Y., Tolentino, R. E., et al. (2023) · Frontiers in Pharmacology · doi:10.3389/fphar.2023.1225759 · Cited by 3
Coarse grained models: the kinetics of motor proteins
Lattanzi, G., & Maritan, A. (2004) · Computational Materials Science · doi:10.1016/j.commatsci.2004.01.025 · Cited by 3
Structural Organization and Dynamics of Mitochondria in the Cells in Vivo
Kuznetsov, A. V. (2007) · Wiley eBooks · doi:10.1002/9783527621095.ch5 · Cited by 4
Biophysical Measurements on Axonemal Dyneins
Kojima, H., Toba, S., Sakakibara, H., & Oiwa, K. (2009) · Methods in cell biology · doi:10.1016/s0091-679x(08)92006-9 · Cited by 3
Chemical Characterization of Single Cells and Single Molecules
Yeung, E. S. (1999) · Journal of the Chinese Chemical Society · doi:10.1002/jccs.199900051 · Cited by 3
Modelling organelle transport after traumatic axonal injury
Kuznetsov, I. A., & Kuznetsov, A. V. (2013) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2013.820721 · Cited by 3
“Indeed, according to Leduc et al. (2004) and Beeg et al. (2008), the average attachment rate to MTs for kinesin-1 is estimated to be 5 s21 while the average detachment rate from MTs for kinesin-1 is estimated to be 1 s21 (Vale et al. 1996; Schnitzer et al. 2000).”
BackgroundKuznetsov, A. V. (2010) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255841003664727 · Cited by 3
“For cytoplasmic dynein, the average attachment rate to MTs is estimated as 1.5 s21 (Vale et al. 1996; Carter and Cross 2005), while the average detachment rate from MTs is estimated as 0.25 s21 (King and Schroer 2000; Reck-Peterson et al. 2006).”
BackgroundInfluentialA THREE-KINETIC-STATE MODEL OF AXONAL TRANSPORT DRUG DELIVERY
Kuznetsov, A. V. (2011) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s021951941100468x · Cited by 3
Peptide–Antibody Complex as Handle for Single‐Molecule Cut & Paste
Strackharn, M., Ståhl, S., Severin, P. M. D., Nicolaus, T., & Gaub, H. E. (2011) · ChemPhysChem · doi:10.1002/cphc.201100765 · Cited by 3
Single molecule fluorescence spectroscopy for quantitative biological applications
Liu, R., Li, Y., & Liu, L. (2016) · Quantitative Biology · doi:10.1007/s40484-016-0083-0 · Cited by 3
Fluorescence microscopy applied to intracellular transport by microtubule motors
Pathak, D., Thakur, S., & Mallik, R. (2018) · Journal of Biosciences · doi:10.1007/s12038-018-9765-2 · Cited by 3
“kinesin moving on microtubules in a TIRF-based assay using microtubule-coated coverslips (Vale et al. 1996).”
MethodQuality Control in Single-Molecule Studies of Kinesins and Microtubule-Associated Proteins
Brouhard, G. J. (2010) · Methods in cell biology · doi:10.1016/s0091-679x(10)97026-x · Cited by 3
“in the first observations of single kinesins (Vale et al., 1996) and continues to serve as an important control.”
BackgroundMethodInfluentialFluorescence-Based Assays for Microtubule Architecture
Bechstedt, S., & Brouhard, G. J. (2013) · Methods in cell biology · doi:10.1016/b978-0-12-407757-7.00021-9 · Cited by 3
Single‐Molecule Spectroscopy of Motor Proteins
Prevo, B., Açar, Ş., Kruijssen, D. L. H., & Peterman, E. J. G. (2000) · Wiley eBooks · doi:10.1002/9780470027318.a9267 · Cited by 3
“The field of single-motor-protein fluorescence studies emerged from first measurements on Kinesin-1, the prototypical processive motor protein (73).”
Goldman, Y. E. (2008) · Wiley eBooks · doi:10.1002/9783527626137.ch3 · Cited by 3
Myosin and kinesin: mother and child reunited
Hackney, D. D. (1996) · Chemistry & Biology · doi:10.1016/s1074-5521(96)90142-8 · Cited by 3
Molecular motors: single-molecule recordings made easy.
Diez, S., Schief, W., & Howard, J. (2002) · Current Biology · doi:10.1016/s0960-9822(02)00750-9 · Cited by 5
“Using total internal reflection fluorescence microscopy, the processive movement of individual kinesin molecules along microtubules was visualized by labeling the motor with Cy-3 [12] or with the green fluorescent protein (GFP) [13].”
MethodHensley, P., & Smith, L. M. (1997) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(97)80150-4 · Cited by 3
The Dynamic Architecture of the Bacillus Cell
Sharp, M. D., & Pogliano, K. (2014) · ASM Press eBooks · doi:10.1128/9781555817992.ch3 · Cited by 3
Impact of physiological ionic strength and crowding on kinesin-1 motility
Sagawa, M., Oiwa, K., Kojima, H., Furuta, K., & Shibata, K. (2025) · Cell Structure and Function · doi:10.1247/csf.24074 · Cited by 2
“The continuing development of in vitro reconstitution systems has facilitated our understanding of the physical and chemical properties of these motors (Block et al. , 1990; Howard et al. , 1989; Vale et al. , 1996; Vale and Toyoshima, 1988).”
Biased movement of monomeric kinesin-3 KLP-6 explained by a symmetric Brownian ratchet model
Kita, T., Sasaki, K., & Niwa, S. (2024) · Biophysical Journal · doi:10.1016/j.bpj.2024.11.3312 · Cited by 2
Multimotor cargo navigation in microtubule networks with various mesh sizes
Grieb, M., Krishnan, N., & Ross, J. L. (2025) · Physical review. E · doi:10.1103/physreve.111.024413 · Cited by 3
Motor function of unconventional myosin.
Ikebe, M., Inoue, A., Nishikawa, S., Homma, K., Tanaka, H., Iwane, A., Katayama, E., Ikebe, R., & Yanagida, T. (2003) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4419-9029-7_13 · Cited by 3
Self-citationSignalpaar‐Korrelationsanalyse von Einzelmolekültrajektorien
Hoffmann, A., & Woodside, M. T. (2011) · Angewandte Chemie · doi:10.1002/ange.201104033 · Cited by 2
The kinesin–tubulin complex: considerations in structural and functional complexity
Paluh, J. L., Colliver, A. G., & Olmsted, Z. T. (2015) · Cell Health and Cytoskeleton · doi:10.2147/chc.s75310 · Cited by 3
Modeling organelle transport in branching dendrites with a variable cross-sectional area
Kuznetsov, A. V. (2010) · Journal of Biological Physics · doi:10.1007/s10867-010-9191-7 · Cited by 2
“[23]) while its average detachment rate from MTs ( ̃k′− ) is estimated to be 0.”
BackgroundKuznetsov, A. V. (2012) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2012.716047 · Cited by 2
“( 1996 ), kinesin-1 (conventional kinesin) walks to the MT plus end with the average velocity of 1 μm s − 1 , while according to King and Schroer ( 2000 ) and Toba et al.”
BackgroundMethodInfluentialCeunynck, K. D., Rocha, S., Meyer, S. F. D., Sadler, J. E., Uji‐i, H., Deckmyn, H., Hofkens, J., & Vanhoorelbeke, K. (2014) · Journal of Biological Chemistry · doi:10.1074/jbc.m113.535963 · Cited by 2
“SM measurements have been extensively applied to track proteins in membranes of living cells (24, 25) or lipid bilayers (26), following motor proteins along the cytoskeleton (27, 28) and DNA-binding proteins on DNA (29 – 32).”
MethodОсадько, И. С., & Khots, E. V. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp056037t · Cited by 2
Numerical investigation of axonal cargo rerouting in a dendrite: A three kinetic state model
Kuznetsov, A. V. (2012) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2521 · Cited by 2
“[29] and Carter and Cross [31], kinesin-1 walks to the MT plus-end with an average velocity of 1 m/s.”
BackgroundA four kinetic state model of fast axonal transport: Model formulation and perturbation solution
Kuznetsov, A. V. (2010) · Open Physics · doi:10.2478/s11534-010-0032-x · Cited by 2
Nakano, T., Egashira, H., Suzuki, J., Mitzman, J. S., & Fukuda, H. (2017) · International Conference on Bio-Inspired Models of Network, Information and Computing Systems (BIONETICS) · doi:10.4108/eai.22-3-2017.152411 · Cited by 2
Mg2+‐free ATP regulates the processivity of native cytoplasmic dynein
Behrens, V. A., Walter, W. J., Peters, C., Wang, T., Brenner, B., Geeves, M. A., Scholz, T., & Steffen, W. (2018) · FEBS Letters · doi:10.1002/1873-3468.13319 · Cited by 2
Processivity of molecular motors under vectorial loads
Khataee, H., Neufeld, Z., & Mahamdeh, M. (2020) · Physical review. E · doi:10.1103/physreve.102.022406 · Cited by 2
Šablinskas, V., Steiner, G. R., Hof, M., & Macháň, R. (2014) · Wiley eBooks · doi:10.1002/9783527654703.ch6 · Cited by 2
Walla, P. J. (2014) · Wiley eBooks · doi:10.1002/9783527683505.ch09 · Cited by 2
Single molecule detection and fluorescence correlation spectroscopy on surfaces
Hassler, K. (2005) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · doi:10.5075/epfl-thesis-3433 · Cited by 2
Single biomolecule studies using optical tweezers
Husale, S. (2005) · edoc (University of Basel) · doi:10.5451/unibas-003683421 · Cited by 3
Sinha, R. (2011) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-3156 · Cited by 2
Kitoh‐Nishioka, H., Ueda, N., & Kakitani, T. (2008) · BIOPHYSICS · doi:10.2142/biophysics.4.19 · Cited by 2
In Vivo Imaging of Mammalian Cells: Image Acquisition and Analysis: Figure 1.
Swedlow, J. R., Andrews, P. D., & Platani, M. (2009) · Cold Spring Harbor Protocols · doi:10.1101/pdb.ip70 · Cited by 3
“Recent interest has developed in very high-resolution, high-sensitivity fluorescence imaging in which single fluorescent molecules are detected and tracked over time (Vale et al.1996).”
BackgroundGoody, R. S. (1996) · Nature · doi:10.1038/380483a0 · Cited by 2
Tokunaga, K., & Akiyama, R. (2012) · Journal of the Physical Society of Japan · doi:10.1143/jpsjs.81sa.sa019 · Cited by 2
Intracellular force comparison of pathogenic KIF1A, KIF5, and dynein by fluctuation analysisPreprint
Hayashi, K., Matsumoto, S., Naoi, T., & Idobata, Y. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.09.12.459977 · Cited by 2
Janke, C., Akhmanova, A. S., Bartolini, F., Bodakuntla, S., Bene, F. D., Hamel, V., Mitchison, T. J., Müller‐Reichert, T., Nédélec, F., Nogales, E., et al. (2026) · Nature Reviews Molecular Cell Biology · doi:10.1038/s41580-026-01011-w · Cited by 1
“Technological breakthroughs enabled the visualization and manipulation of individual molecules 214–216 (Fig.”
In Vivo Single-Molecule Microscopy Using the Zebrafish Model System
Schaaf, M. J. M., & Schmidt, T. S. (2010) · Springer eBooks · doi:10.1007/978-90-481-9864-1_9 · Cited by 1
“TIRF microscopy has previously been used to image single fluorescently labeled kinesin molecules [45] and ATP molecules [43] in vitro, and for imaging of individual membrane proteins in cell cultures [14, 36].”
MethodMonte Carlo simulation on backward steps of single kinesin molecule
Wang, H., Zhang, Y., Dou, S., & Peng-Ye, W. (2008) · Chinese Physics B · doi:10.1088/1674-1056/17/4/060 · Cited by 2
Schwille, P. (2019) · Springer eBooks · doi:10.1007/978-3-662-58035-6_25 · Cited by 1
Davis, B. J. (2006) · PhDT · Cited by 1
Molecular Motors: Subdomain Dynamics and Mechanochemistry
Singh, M., & Singh, S. K. (2020) · Springer eBooks · doi:10.1007/978-981-15-5530-5_15 · Cited by 1
Чернобельская, О. А., Grigoriev, I., Alieva, I. B., & Vorobjev, I. A. (2001) · Russian Journal of Developmental Biology · doi:10.1023/a:1009413211185 · Cited by 1
“On the one hand, saltatory movements are easy to monitor and, hence, can be measured fairly accurately; on the other, their range may be shorter than the actual microtubule length because of a limited processiveness of motors, kinesin and dynein (Vale et al., 1996; Okada and Hirokawa, 1999).”
BackgroundBressloff, P. C. (2014) · Interdisciplinary applied mathematics · doi:10.1007/978-3-319-08488-6_4 · Cited by 1
Prevo, B., & Peterman, E. J. G. (2015) · eLife · doi:10.7554/elife.08366 · Cited by 1
“After binding to a microtubule, a single kinesin protein can take more than one hundred steps along it before detaching, and many aspects of this characteristic—which is called processivity—are not fully understood (Block et al., 1990; Vale et al., 1996).”
Metadata
- Authors
- Vale, R. D., Funatsu, T., Pierce, D. W., Romberg, L., Harada, Y., & Yanagida, T.
- Affiliations
- Howard Hughes Medical Institute (US)
- University of California, San Francisco (US)
- The University of Osaka (JP)
- Venue
- Nature
- Published
- 1996-04
- Volume
- 380
- Issue
- 6573
- Pages
- 451-453
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- PMC
- PMC2852185
- OpenAlex
- W1963863239
- Cited by
- 711
- References
- 23
- Citations by year
- 2026: 5 · 2025: 10 · 2024: 10 · 2023: 11 · 2022: 10 · 2021: 20 · 2020: 11 · 2019: 19 · 2018: 13 · 2017: 22 · 2016: 15 · 2015: 26 · 2014: 22 · 2013: 26 · 2012: 23
- FWCI
- 14.18
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Howard Hughes Medical Institute
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (P01AR042895)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Microtubule and mitosis dynamics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Keywords
- kinesin, microtubules, processive movement, motor proteins, organelle transport, single-molecule observation, total internal reflection fluorescence microscopy, hand-over-hand mechanism, motor domain, ATP hydrolysis, salt effects
- MeSH terms
- Amino Acid Sequence, Animals, Drosophila, Escherichia coli, Humans, Microscopy, Fluorescence, Microtubules, Molecular Sequence Data, Osmolar Concentration, Peptide Fragments, Recombinant Fusion Proteins, Kinesins
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.