Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 233

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

A five-microRNA panel in plasma was identified as potential biomarker for early detection of gastric cancer

Open access
Zhu, C, Ren, C, Han, J, Ding, Y, Du, J, Dai, N, Dai, J, Ma, H, Hu, Z, Shen, H, Xu, Y, Jin, G·2014·British Journal of Cancer

Abstract

BACKGROUND: Circulating microRNAs (miRNAs) have been implicated as novel biomarkers for gastric cancer (GC) diagnosis. However, the mixture of GC subtypes may have led to the inconsistent circulating miRNA profiles, and the clinical performance of circulating miRNAs has not yet been evaluated independently on early detection of GC. METHODS: A four-phase study was designed with a total of 160 cancer-free controls, 124 patients with gastric non-cardia adenocarcinoma (GNCA) and 36 patients diagnosed gastric cardia adenocarcinoma (GCA). In the discovery phase, we screened the miRNA expression profile in plasma of 40 GNCA patients (stage I) and 40 matched controls by TaqMan low density array (TLDA) chips with pooled samples. Differentially expressed miRNAs were further validated in individual sample using quantitative reverse-transcriptase PCR (qRT-PCR) in the training phase. Subsequently, in an independent validation phase, the identified miRNAs were evaluated in 48 GNCA patients (stage I) and 102 matched controls. Finally, the identified miRNAs were further assessed in an external validation phase including advanced GNCA and GCA patients. Additionally, the expression levels of identified miRNAs were measured in the media of BGC823 and MGC803 cell lines. RESULTS: Five miRNAs (miR-16, miR-25, miR-92a, miR-451 and miR-486-5p) showed consistently elevated levels in plasma of the GC patients as compared with controls, and were identified to be potential markers for GNCA with area under the receiver operating characteristic (ROC) curves (AUCs) ranging from 0.850 to 0.925 and 0.694 to 0.790 in the training and validation phases, respectively. The five-miRNA panel presented a high diagnostic accuracy for the early-stage GNCA (AUCs=0.989 and 0.812 for the training and validation phases, respectively). Three miRNAs (miR-16, miR-25 and miR-92a) were excreted into the culture media of GC cell lines. CONCLUSIONS: The five-miRNA panel in plasma may serve as a potential non-invasive biomarker in detecting the early-stage GC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/bjc.2014.119

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 233

Metadata

Authors
Zhu, C., Ren, C., Han, J., Ding, Y., Du, J., Dai, N., Dai, J., Ma, H., Hu, Z., Shen, H., Xu, Y., & Jin, G.
Venue
British Journal of Cancer
Published
2014-03-04
Volume
110
Issue
9
Pages
2291-2299
ISSN
  • 0007-0920 (ISSN-L)
  • 1532-1827
OpenAlex
W1978087759
Cited by
233
References
3
FWCI
9.62
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A five-microRNA panel in plasma was identified as potential biomarker for early detection of gastric cancer. https://app.cochat.ai/papers/10.1038/bjc.2014.119
The paper
Zhu, C., Ren, C., Han, J., Ding, Y., Du, J., Dai, N., Dai, J., Ma, H., Hu, Z., Shen, H., Xu, Y., & Jin, G. (2014). A five-microRNA panel in plasma was identified as potential biomarker for early detection of gastric cancer. British Journal of Cancer. https://doi.org/10.1038/bjc.2014.119

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.