Assessment of EchoMRI-AH versus dual-energy X-ray absorptiometry to measure human body composition
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Background:The sensitivity to detect small changes in body composition (fat mass and fat-free mass) largely depends on the precision of the instrument. We compared EchoMRI-AH and dual-energy X-ray absorptiometry (DXA) (Hologic QDR-4500A) for estimating fat mass in 301 volunteers.Methods:Body composition was evaluated in 136 males and 165 females with a large range of body mass index (BMI) (19−49 kg m−2) and age (19−91 years old) using DXA and EchoMRI-AH. In a subsample of 13 lean (BMI=19–25 kg m−2) and 21 overweight/obese (BMI>25 kg m−2) individuals, within-subject precision was evaluated from repeated measurements taken within 1 h (n=3) and 1 week apart (mean of three measurements taken on each day).Results:Using Bland–Altman analysis, we compared the mean of the fat mass measurements versus the difference in fat mass measured by both instruments. We found that EchoMRI-AH quantified larger amount of fat versus DXA in non-obese (BMI<30 kg m−2 (1.1 kg, 95% confidence interval (CI95):−3.7 to 6.0)) and obese (BMI⩾30 kg m−2 (4.2 kg, CI95:−1.4 to 9.8)) participants. Within-subject precision (coefficient of variation, %) in fat mass measured within 1 h was remarkably better when measured by EchoMRI-AH than DXA (<0.5 versus <1.5%, respectively; P<0.001). However, 1-week apart within-subject variability showed similar values for both instruments (<2.2%; P=0.15).Conclusions:EchoMRI-AH yielded greater fat mass values when compared with DXA (Hologic QDR-4500A), particularly in fatter subjects. EchoMRI-AH and DXA showed similar 1-week apart precision when fat mass was measured both in lean and overweight/obese individuals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Dual-energy X-ray absorptiometry body composition model: review of physical concepts
Pietrobelli, A., Formica, C., Wang, Z., & Heymsfield, S. B. (1996) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1996.271.6.e941 · Cited by 594
Schoeller, D. A., Tylavsky, F. A., Baer, D. J., Chumlea, W. C., Earthman, C. P., Fuerst, T., Harris, T. B., Heymsfield, S. B., Horlick, M., Lohman, T. G., et al. (2005) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/81.5.1018 · Cited by 253
Within- and between-subject variation in commonly measured anthropometric and biochemical variables
Widjaja, A., Morris, R. J., Levy, J. C., Frayn, K. N., Manley, S. E., & Turner, R. C. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.4.561 · Cited by 129
Cited by
Heymsfield, S. B., Gonzalez, M. C. C., Shen, W., Redman, L., & Thomas, D. (2014) · Obesity Reviews · doi:10.1111/obr.12143 · Cited by 350
Hangartner, T. N., Warner, S., Braillon, P., Jankowski, L., & Shepherd, J. (2013) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2013.08.007 · Cited by 242
Pownall, H. J., Bray, G. A., Wagenknecht, L. E., Walkup, M. P., Heshka, S., Hubbard, V. S., Hill, J., Kahn, S. E., Nathan, D. M., Schwartz, A. V., et al. (2015) · Obesity · doi:10.1002/oby.21005 · Cited by 94
Patel, K. V., Bahnson, J. L., Gaussoin, S. A., Johnson, K. C., Pi-Sunyer, X., White, U., Olson, K. L., Bertoni, A. G., Kitzman, D. W., Berry, J. D., et al. (2020) · Circulation · doi:10.1161/circulationaha.120.050941 · Cited by 69
Body Composition During Pregnancy: Longitudinal Changes and Method Comparisons
Bosaeus, M., Andersson-Hall, U., Andersson, L., Karlsson, T., Ellegård, L., & Holmäng, A. (2020) · Reproductive Sciences · doi:10.1007/s43032-020-00141-6 · Cited by 28
Metadata
- Authors
- Galgani, J. E., Smith, S. R., & Ravussin, E.
- Venue
- International Journal of Obesity
- Published
- 2011-01-11
- Volume
- 35
- Issue
- 9
- Pages
- 1241-1246
- ISSN
- 0307-0565 (ISSN-L)
- 1476-5497
- OpenAlex
- W2022703899
- Cited by
- 21
- References
- 4
- FWCI
- 0.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of EchoMRI-AH versus dual-energy X-ray absorptiometry to measure human body composition. https://app.cochat.ai/papers/10.1038/ijo.2010.268
- The paper
- Galgani, J. E., Smith, S. R., & Ravussin, E. (2011). Assessment of EchoMRI-AH versus dual-energy X-ray absorptiometry to measure human body composition. International Journal of Obesity. https://doi.org/10.1038/ijo.2010.268
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.