Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 193

The DOI matches its Crossref record.

Cerebral Blood Volume Measured with Inhaled C15O and Positron Emission Tomography

Martin, W. R. Wayne, Powers, William J., Raichle, Marcus E.·1987·Journal of Cerebral Blood Flow & Metabolism

Abstract

Local cerebral blood volume (CBV) has been measured previously with inhaled 11 CO and positron emission tomography (PET). The model used assumes that equilibrium in tracer concentration has occurred between arterial and systemic venous blood before the PET measurement is made. To verify that this model may be used with the much shorter half-lived C 15 O, we have simultaneously measured arterial and venous blood radioactivity following C 15 O inhalation. Equilibrium occurred 95 ± 39 s after inhalation (n = 7). If the PET measurement is commenced prior to arteriovenous equilibrium, significant errors occur in calculated CBV. These data indicate that C 15 O may be used as a tracer for CBV measurement provided that emission data collection commences at ∼120 s after inhalation. Strict quality control measures must be maintained to minimize the contamination of administered C 15 O with 15 O-labeled CO 2.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/jcbfm.1987.85

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 193

Metadata

Authors
Martin, W. R. W., Powers, W. J., & Raichle, M. E.
Venue
Journal of Cerebral Blood Flow & Metabolism
Published
1987-08
Volume
7
Issue
4
Pages
421-426
ISSN
  • 0271-678X (ISSN-L)
  • 1559-7016
OpenAlex
W1991707478
Cited by
193
References
0
FWCI
6.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cerebral Blood Volume Measured with Inhaled C15O and Positron Emission Tomography. https://app.cochat.ai/papers/10.1038/jcbfm.1987.85
The paper
Martin, W. R. W., Powers, W. J., & Raichle, M. E. (1987). Cerebral Blood Volume Measured with Inhaled C15O and Positron Emission Tomography. Journal of Cerebral Blood Flow & Metabolism. https://doi.org/10.1038/jcbfm.1987.85

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.