The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Enhanced Detection of Focal Brain Responses Using Intersubject Averaging and Change-Distribution Analysis of Subtracted PET Images
Open accessAbstract
Intersubject averaging and change-distribution analysis of subtracted positron emission tomographic (PET) images were developed and tested. The purpose of these techniques is to increase the sensitivity and objectivity of functional mapping of the human brain with PET. To permit image averaging, all primary tomographic images were converted to anatomically standardized three-dimensional images using stereotactic anatomical localization and interslice interpolation. Image noise, measured in control-minus-control subtractions, was strongly suppressed by averaging. Signal-to-noise ratio, measured in stimulus-minus-control subtractions (hand vibration minus eyes-closed rest), rose steadily with averaging, confirming the accuracy of our method of anatomical standardization. Distribution analysis of CBF change images (outlier detection by gamma-2 statistic) was assessed as an omnibus test for state-dependent changes in regional neuronal activity. Sensitivity in detecting the somatosensory response rose steadily with averaging, increasing from 50% in individual images to 100% when three or more images were averaged. Specificity was 100% at all averaging levels. Although described here as a technique for functional brain mapping with H 215 O CBF images, image averaging, and change-distribution analysis are more generally applicable techniques, not limited to a single purpose or tracer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biostatistical Analysis (2nd ed.).
Breen, T. J., & Zar, J. H. (1986) · Journal of the American Statistical Association · doi:10.2307/2289268 · Cited by 5,781
Procedures for Detecting Outlying Observations in Samples
Grubbs, F. E. (1969) · Technometrics · doi:10.1080/00401706.1969.10490657 · Cited by 4,105 · cited 1×
“This suggested the potential utility of outlier detection analysis (Grubbs, 1969) for dis criminating physiological responses from image”
BackgroundPositron emission tomographic studies of the cortical anatomy of single-word processing
Petersen, S. E., Fox, P. T., Posner, M. I., Mintun, M., & Raichle, M. E. (1988) · Nature · doi:10.1038/331585a0 · Cited by 2,593
Self-citationFox, P. T., & Raichle, M. E. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.4.1140 · Cited by 2,056 · cited 1×
“The stimulus employed was vibration (130 Hz, 2-mm ampli tude) of the fingers of the left hand (Fox and Raichle, 1986; Fox et aI., 1987a).”
MethodSelf-citationBiometrika Tables for Statisticians
Savage, I. R., Pearson, E. S., & Hartley, H. O. (1967) · Mathematics of Computation · doi:10.2307/2004190 · Cited by 1,435
Brain blood flow measured with intravenous H2(15)O. II. Implementation and validation.
Raichle, M. E., Martin, W. R. W., Herscovitch, P., Mintun, M. A., & Markham, J. (1983) · PubMed · Cited by 1,015
Self-citationAn omnibus test of normality for moderate and large size samples
D'AGOSTINO, R. B. (1971) · Biometrika · doi:10.1093/biomet/58.2.341 · Cited by 581
A Stereotactic Method of Anatomical Localization for Positron Emission Tomography
Fox, P. T., Perlmutter, J. S., & Raichle, M. E. (1985) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198501000-00025 · Cited by 572
Self-citationFox, P. T., & Raichle, M. E. (1984) · Journal of Neurophysiology · doi:10.1152/jn.1984.51.5.1109 · Cited by 498
Self-citationMapping human visual cortex with positron emission tomography
Fox, P. T., Mintun, M. A., Raichle, M. E., Miezin, F. M., Allman, J. M., & Van Essen, D. C. (1986) · Nature · doi:10.1038/323806a0 · Cited by 422
Retinotopic organization of human visual cortex mapped with positron- emission tomography
Fox, P., Miezin, F., Allman, J., Van Essen, D., & Raichle, M. (1987) · The Journal of Neuroscience · doi:10.1523/jneurosci.07-03-00913.1987 · Cited by 364
Self-citationMapping human somatosensory cortex with positron emission tomography
Fox, P. T., Burton, H., & Raichle, M. E. (1987) · Journal of Neurosurgery · doi:10.3171/jns.1987.67.1.0034 · Cited by 271
Self-citationFox, P. T., Mintun, M. A., Raichle, M. E., & Herscovitch, P. (1984) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1984.49 · Cited by 242
Self-citationHerscovitch, P., Raichle, M. E., Kilbourn, M. R., & Welch, M. J. (1987) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1987.102 · Cited by 222
Self-citationPerformance Study of PETT VI, a Positron Computed Tomograph with 288 Cesium Fluoride Detectors
Yamamoto, M., Ficke, D. C., & Ter‐Pogossian, M. M. (1982) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1982.4335901 · Cited by 79
Simulation Probability Points of b 2 for Small Samples
D’Agostino, R. B., & Tietjen, G. L. (1971) · Biometrika · doi:10.1093/biomet/58.3.669 · Cited by 55
Cited by
Statistical parametric maps in functional imaging: A general linear approach
Friston, K. J., Holmes, A. P., Worsley, K. J., Poline, J. ‐., Frith, C. D., & Frackowiak, R. S. J. (1994) · Human Brain Mapping · doi:10.1002/hbm.460020402 · Cited by 9,688
Spatial registration and normalization of images
Friston, K. J., Ashburner, J., Frith, C. D., Poline, J. ‐., Heather, J. D., & Frackowiak, R. S. J. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030303 · Cited by 3,744
Automated Talairach Atlas labels for functional brain mapping
Lancaster, J. L., Woldorff, M. G., Parsons, L. M., Liotti, M., Freitas, C. S., Rainey, L., Kochunov, P. V., Nickerson, D., Mikiten, S. A., & Fox, P. T. (2000) · Human Brain Mapping · doi:10.1002/1097-0193(200007)10:3<120::aid-hbm30>3.0.co;2-8 · Cited by 3,387
Self-citationMurphy, K., Birn, R. M., Handwerker, D. A., Jones, T. B., & Bandettini, P. A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.09.036 · Cited by 2,387
“The global signal correction technique has beenwidely used in the PET imaging literature to remove global blood flow fluctuations with some debate as to the appropriate removal method (Andersson et al., 2001; Arndt et al., 1996; Fox et al., 1988; Friston et al., 1990; Ramsay et al., 1993).”
A three-dimensional statistical analysis for CBF activation studies in human brain
Worsley, K. J., Evans, A. C., Marrett, S., & Neelin, P. (1992) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1992.127 · Cited by 2,036
Metadata
- Authors
- Fox, P. T., Mintun, M. A., Reiman, E. M., & Raichle, M. E.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 1988-10
- Volume
- 8
- Issue
- 5
- Pages
- 642-653
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W2057468044
- Cited by
- 498
- References
- 16
- FWCI
- 13.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.