CoChat

Neuroreceptor Quantitation in vivo by the Steady-State Principle Using Constant Infusion or Bolus Injection of Radioactive Tracers

Lassen, Niels A. · 1992 · Journal of Cerebral Blood Flow & Metabolism
Cited by 89

The DOI matches its Crossref record.

Abstract

The approaches hitherto used for measuring the kinetic constants K d and B max of neuroreceptors in vivo all violate the steady state of the system. This complicates the kinetic analysis as approximations must be made, introducing errors of unknown magnitude. The present study presents the theory for designing experiments in which the steady state is preserved. It is based on maintaining a constant degree of receptor binding (occupancy) throughout the experiment. This is achieved by administering by prolonged intravenous infusion the non-radioactive ligand one wishes to study. The fraction of receptor sites not occupied by the “cold” ligand is measured by using trace amounts of a radioactive ligand binding to the same receptor. A minimum of two studies at different occupancies must be performed. In this presentation it is proposed to make the second study at essentially zero receptor occupancy by administering the tracer alone. The pair of tracer studies, the one without and the other with infusion of cold ligand, allows calculation of the cold ligand's equilibrium dissociation constant K d. In the special case when tracer and cold ligands are chemically identical, then B max can also be calculated. Two different modes of tracer administration can be used. If the tracer is also infused at a constant rate for a long time, then the occupancy of receptor sites by the cold ligand can be calculated by measuring the equilibrium tracer concentrations in brain and plasma. If the tracer is administered as an intravenous bolus injection, then the area under the brain and plasma radioactivity curves or compartmental analysis must be used. The bolus injection approach, described in this paper for the first time, has the highest overall counting efficiency and should therefore be particularly suited for studies in man using positron emission tomography (PET) or single photon emission tomography (SPECT). Tracer infusion is the method of choice for animal experiments, as only one set of values are needed, those at long time, as can be obtained post vivo by counting samples of brain or by using autoradiographic techniques. The steady-state principle shows that ligands with very low K d values, i.e., with very high affinity, are not suited for receptor quantitation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/jcbfm.1992.101

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 89

Metadata

Authors
Lassen, N. A.
Venue
Journal of Cerebral Blood Flow & Metabolism
Published
1992-09
Volume
12
Issue
5
Pages
709-716
ISSN
  • 0271-678X (ISSN-L)
  • 1559-7016
OpenAlex
W2092111603
Cited by
89
References
0
FWCI
1.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Neuroreceptor Quantitation in vivo by the Steady-State Principle Using Constant Infusion or Bolus Injection of Radioactive Tracers. https://app.cochat.ai/papers/10.1038/jcbfm.1992.101
The paper
Lassen, N. A. (1992). Neuroreceptor Quantitation in vivo by the Steady-State Principle Using Constant Infusion or Bolus Injection of Radioactive Tracers. Journal of Cerebral Blood Flow & Metabolism. https://doi.org/10.1038/jcbfm.1992.101

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.