Blood Flow in Single Surface Arterioles and Venules on the Mouse Somatosensory Cortex Measured with Videomicroscopy, Fluorescent Dextrans, Nonoccluding Fluorescent Beads, and Computer-Assisted Image Analysis

Open access
Rovainen, Carl M., Woolsey, Thomas A., Blocher, Nissa C., Wang, Dan-Bing, Robinson, Orlando F. · 1993 · Journal of Cerebral Blood Flow & Metabolism
Cited by 80

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Cortical surface vessels were monitored through closed cranial windows with an epifluorescence microscope and SIT or ICCD cameras. Fluorescent dextrans or 1.3 μm latex beads were injected into the contralateral jugular vein for plasma labeling and for vascular transits. For close arterial transits, these tracers or physiological saline were injected into the ipsilateral external carotid artery. AVTTs were calculated from intensity differences of tracers between a branch of the MCA and a vein draining the same cortical region over time. AVTTs for saline dilutions of RBCs were significantly shorter (0.73 times) than for dextrans. Both dextrans and beads distributed with plasma. With FITC–dextran, inner diameters of arterioles and venules averaged 6 μm larger than hemoglobin under green light. This difference was likely due to the segregation of red blood cells and plasma during flow. Velocities of individual fluorescent beads were measured in pial vessels by strobe epi-illumination. Plots of bead velocities against radial position in arterioles were blunted parabolas. Peak shear rates in the marginal layer next to the vessel walls were determined directly from bead tracks in arterioles ( D = 21–71 μm) and were 1.32 times the Poiseuille estimate. The calculated peak wall shear stress was 39 ± 14 dyn/cm 2 (mean ± SD) for these arterioles but was probably severalfold greater in the smallest terminal pial arterioles. V max near the axes of arterioles increased with D +0.5 . The calculated peak wall shear rate was highest in small arterioles and decreased with D −0.5 . The calculated flow Q increased with D +2.5 . These methods permit direct, simultaneous, dynamic measurements on multiple identified cerebral microvessels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/jcbfm.1993.49

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 80

Metadata

Authors
Rovainen, C. M., Woolsey, T. A., Blocher, N. C., Wang, D.-B., & Robinson, O. F.
Venue
Journal of Cerebral Blood Flow & Metabolism
Published
1993-05
Volume
13
Issue
3
Pages
359-371
ISSN
  • 0271-678X (ISSN-L)
  • 1559-7016
OpenAlex
W2028959463
Cited by
80
References
2
FWCI
3.07
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.