CoChat

The applicability of SRTM in [18F]fallypride PET investigations: Impact of scan durations

Open access
Vernaleken, Ingo, Peters, Lisa, Raptis, Mardjan, Lin, Robert, Buchholz, Hans-Georg, Zhou, Yun, Winz, Oliver, Rösch, Frank, Bartenstein, Peter, Wong, Dean F, Scháfer, Wolfgang M, Gründer, Gerhard · 2011 · Journal of Cerebral Blood Flow & Metabolism
Cited by 40

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The high-affinity radioligand [18 F]fallypride (FP) is frequently used for quantification of striatal/extrastriatal D 2/3 receptors and the receptor occupancies of antipsychotics (APs). Its 110 minutes half-life allows long scan durations. However, the optimum scan duration is a matter of debate. This investigation focuses on scan-duration-related effects on simplified reference tissue model (SRTM) results and the time point of transient equilibrium in a large sample of dynamic FP positron emission tomography (PET) scans. Fifty drug-free and 50 AP-treated subjects underwent FP-PET scans (180 minutes scan duration). The binding potential ( BP ND) of the putamen, thalamus, and temporal cortex were calculated using the SRTM and the transient equilibrium model. Furthermore, receptor occupancies were calculated for AP-treated patients. Transient equilibrium in the unblocked putamen occurred after 121 ± 29.6 minutes. The transient equilibrium occurred much earlier in the extrastriatal regions or under AP treatment. Stepwise scan shortening caused BP ND under-estimations of 0.58% for the first 10-minute reduction (putamen, SRTM), finally reaching 5.76% after 1 hour scan-time reduction. We observed preferential extrastriatal AP binding irrespective of the analytical method. [18 F]fallypride scan durations of 180 minutes reliably reach equilibrium even in D 2/3-receptor-rich regions. Moderate reductions in FP scan durations only caused small changes to SRTM results even in receptor-rich regions. Apparently, the D 2/3 receptor occupancy results of APs, especially preferential extrastriatal binding observations, are not relevantly biased by inappropriate scan durations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/jcbfm.2011.73

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 40

Metadata

Authors
Vernaleken, I., Peters, L., Raptis, M., Lin, R., Buchholz, H.-G., Zhou, Y., Winz, O., Rösch, F., Bartenstein, P., Wong, D. F., Scháfer, W. M., & Gründer, G.
Venue
Journal of Cerebral Blood Flow & Metabolism
Published
2011-05-18
Volume
31
Issue
9
Pages
1958-1966
ISSN
  • 0271-678X (ISSN-L)
  • 1559-7016
OpenAlex
W2140904722
Cited by
40
References
1
FWCI
2.99
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.