CoChat

Determination of [11C]PBR28 Binding Potential in vivo: A First Human TSPO Blocking Study

Open access
Owen, David R, Guo, Qi, Kalk, Nicola J, Colasanti, Alessandro, Kalogiannopoulou, Dimitra, Dimber, Rahul, Lewis, Yvonne L, Libri, Vincenzo, Barletta, Julien, Ramada-Magalhaes, Joaquim, Kamalakaran, Aruloly, Nutt, David J, Passchier, Jan, Matthews, Paul M, Gunn, Roger N, Rabiner, Eugenii A · 2014 · Journal of Cerebral Blood Flow & Metabolism
Cited by 133

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Positron emission tomography (PET) targeting the 18 kDa translocator protein (TSPO) is used to quantify neuroinflammation. Translocator protein is expressed throughout the brain, and therefore a classical reference region approach cannot be used to estimate binding potential ( BP ND). Here, we used blockade of the TSPO radioligand [11 C]PBR28 with the TSPO ligand XBD173, to determine the non-displaceable volume of distribution ( V ND), and hence estimate the BP ND. A total of 26 healthy volunteers, 16 high-affinity binders (HABs) and 10 mixed affinity binders (MABs) underwent a [11 C]PBR28 PET scan with arterial sampling. Six of the HABs received oral XBD173 (10 to 90 mg), 2 hours before a repeat scan. In XBD173-dosed subjects, V ND was estimated via the occupancy plot. Values of BP ND for all subjects were calculated using this V ND estimate. Total volume of distribution ( V T) of MABs (2.94 ± 0.31) was lower than V T of HABs (4.33 ± 0.29) ( P<0.005). There was dose-dependent occupancy of TSPO by XBD173 (ED50 = 0.34 ± 0.13 mg/kg). The occupancy plot provided a V ND estimate of 1.98 (1.69, 2.26). Based on these V ND estimates, BP ND for HABs is approximately twice that of MABs, consistent with predictions from in vitro data. Our estimates of [11 C]PBR28 V ND and hence BP ND in the healthy human brain are consistent with in vitro predictions. XBD173 blockade provides a practical means of estimating V ND for TSPO targeting radioligands.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/jcbfm.2014.46

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 133

Metadata

Authors
Owen, D. R., Guo, Q., Kalk, N. J., Colasanti, A., Kalogiannopoulou, D., Dimber, R., Lewis, Y. L., Libri, V., Barletta, J., Ramada-Magalhaes, J., Kamalakaran, A., Nutt, D. J., Passchier, J., Matthews, P. M., Gunn, R. N., & Rabiner, E. A.
Venue
Journal of Cerebral Blood Flow & Metabolism
Published
2014-03-19
Volume
34
Issue
6
Pages
989-994
ISSN
  • 0271-678X (ISSN-L)
  • 1559-7016
OpenAlex
W1996242543
Cited by
133
References
8
FWCI
7.44
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.