Sensitivity and Specificity of Multiphoton Laser Tomography for In Vivo and Ex Vivo Diagnosis of Malignant Melanoma
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Über Elementarakte mit zwei Quantensprüngen
Göppert‐Mayer, M. (1931) · Annalen der Physik · doi:10.1002/andp.19314010303 · Cited by 2,691 · cited 1×
“MLT is based on multiphoton excitation (Goeppert-Mayer, 1931).”
Zipfel, W. R., Williams, R. M., Christie, R., Nikitin, A. Y., Hyman, B. T., & Webb, W. W. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832308100 · Cited by 1,676 · cited 1×
“Endogenous fluorophores such as NAD(P)H (nicotinamide adenine dinucleotide (phosphate)) coenzymes, flavins, metal-free porphyrins, lipofuscin, melanin, elastin, collagen, and keratin are the primary source of tissue fluorescence (Masters and So, 1999; Koenig and Riemann, 2003; Zipfel et al., 2003).”
Diagnostic accuracy of dermoscopy
Kittler, H., Pehamberger, H., Wolff, K., & Binder, M. (2002) · The Lancet Oncology · doi:10.1016/s1470-2045(02)00679-4 · Cited by 1,349 · cited 1×
“Indeed, dermoscopy by untrained or less experienced observers is not better than clinical inspection with the unaided eye (Kittler et al., 2002).”
Koenig, K., & Riemann, I. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1577349 · Cited by 535 · cited 2×
“Our results were in line with previous MLT studies of human skin (Koenig and Riemann, 2003).”
Bafounta, M.-L., Beauchet, A., Aegerter, P., & Saiag, P. (2001) · Archives of Dermatology · doi:10.1001/archderm.137.10.1343 · Cited by 505 · cited 1×
“In contrast, physicians specialized in the evaluation of pigmented skin disorders by dermoscopyreached sensitivity values of 75–96% and specificity values of 79–98% (Westerhoff et al., 2000; Bafounta et al., 2001).”
Uber Elementarrakte mit zwei Quantensprungen
Goppert-Mayer, V. M. (1931) · Annals of Physics · Cited by 500
Skin biopsy rates and incidence of melanoma: population based ecological study
Welch, H. G., Woloshin, S., & Schwartz, L. M. (2005) · BMJ · doi:10.1136/bmj.38516.649537.e0 · Cited by 330 · cited 2×
“Over the past decades a dramatic increase in the incidence of malignant melanoma has been reported (Garbe and Blum, 2001; Welch et al., 2005; Stang et al., 2007).”
Clinical multiphoton tomography
König, K. (2008) · Journal of Biophotonics · doi:10.1002/jbio.200710022 · Cited by 303 · cited 1×
“In recent years, MLT became a promising procedure with a broad range of biomedical applications (Koenig, 2008).”
Self-citationClinical accuracy of the diagnosis of cutaneous malignant melanoma
Morton, & Mackie (1998) · British Journal of Dermatology · doi:10.1046/j.1365-2133.1998.02075.x · Cited by 247 · cited 1×
“Despite extensive research investigating the physical and morphologic characteristics of melanoma, diagnostic accuracy remains suboptimal, with values ranging from 56 to 81% (Morton and Mackie, 1998; Dolianitis et al., 2005; Annessi et al., 2007).”
Epidemiology of Cutaneous Melanoma in Germany and Worldwide
Garbe, C., & Blum, A. (2001) · Skin Pharmacology and Physiology · doi:10.1159/000056358 · Cited by 209 · cited 2×
“Over the past decades a dramatic increase in the incidence of malignant melanoma has been reported (Garbe and Blum, 2001; Welch et al., 2005; Stang et al., 2007).”
Schenke-Layland, K., Riemann, I., Damour, O., Stock, U. A., & König, K. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.07.004 · Cited by 189 · cited 1×
“Various studies on tissue engineering (Schenke-Layland et al., 2006), in vivo drug monitoring (Koenig et al., 2006), skin aging (Koehler et al., 2008) as well as dermatological disorders (Riemann et al., 2005; Paoli et al., 2008) underline the excellent imaging capabilities.”
Self-citationWesterhoff, K., Mccarthy, W. H., & Menzies, S. W. (2000) · British Journal of Dermatology · doi:10.1046/j.1365-2133.2000.03836.x · Cited by 183 · cited 1×
“In contrast, physicians specialized in the evaluation of pigmented skin disorders by dermoscopyreached sensitivity values of 75–96% and specificity values of 79–98% (Westerhoff et al., 2000; Bafounta et al., 2001).”
Gambichler, T., Regeniter, P., Bechara, F. G., Orlikov, A., Vasa, R., Moussa, G., Stücker, M., Altmeyer, P., & Hoffmann, K. (2007) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2007.05.029 · Cited by 175 · cited 2×
“, 2002), optical coherence tomography (Gambichler et al., 2007) and confocal laser scanning microscopy (Langley et al.”
Instruments and new technologies for the in vivo diagnosis of melanoma
Marghoob, A. A., Swindle, L. D., Moricz, C. Z. M., Sanchez Negron, F. A., Slue, B., Halpern, A. C., & Kopf, A. W. (2003) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(03)02470-8 · Cited by 174 · cited 1×
“In contrast to other non-invasive imaging techniques (Marghoob et al., 2003), MLT offers the unique opportunity to investigate skin structures with subcellular spatial resolution similar to those of light microscopy.”
Paoli, J., Smedh, M., Wennberg, A.-M., & Ericson, M. B. (2008) · Journal of Investigative Dermatology · doi:10.1038/sj.jid.5701139 · Cited by 160 · cited 2×
“, 2008) as well as dermatological disorders (Riemann et al., 2005; Paoli et al., 2008) underline the excellent imaging capabilities.”
Annessi, G., BONO, R., Sampogna, F., Faraggiana, T., & ABENI, D. D. (2007) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2007.01.014 · Cited by 135 · cited 2×
“Despite extensive research investigating the physical and morphologic characteristics of melanoma, diagnostic accuracy remains suboptimal, with values ranging from 56 to 81% (Morton and Mackie, 1998; Dolianitis et al., 2005; Annessi et al., 2007).”
Langley, R. G. B., Walsh, N. M. G., Sutherland, A. E., Propperova, I., Delaney, L., Morris, S. F., & Gallant, C. (2007) · Dermatology · doi:10.1159/000109087 · Cited by 132 · cited 3×
“, 2007) and confocal laser scanning microscopy (Langley et al., 2007) have evolved.”
In vivo Drug Screening in Human Skin Using Femtosecond Laser Multiphoton Tomography
König, K., Ehlers, A., Stracke, F., & Riemann, I. (2006) · Skin Pharmacology and Physiology · doi:10.1159/000091974 · Cited by 132 · cited 2×
“, 2006), in vivo drug monitoring (Koenig et al., 2006), skin aging (Koehler et al.”
Self-citationDolianitis, C., Kelly, J., Wolfe, R., & Simpson, P. (2005) · Archives of Dermatology · doi:10.1001/archderm.141.8.1008 · Cited by 131 · cited 2×
“Despite extensive research investigating the physical and morphologic characteristics of melanoma, diagnostic accuracy remains suboptimal, with values ranging from 56 to 81% (Morton and Mackie, 1998; Dolianitis et al., 2005; Annessi et al., 2007).”
Cutaneous melanin exhibiting fluorescence emission under near-infrared light excitation
Huang, Z., Zeng, H., Hamzavi, I., Alajlan, A., Tan, E., McLean, D. I., & Lui, H. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2204007 · Cited by 116 · cited 1×
“They showed a strong autofluorescence due to the endogenous fluorophore melanin (Teuchner et al., 2003; Huang et al., 2006).”
Koehler, M. J., Hahn, S., Preller, A., Elsner, P. U., Ziemer, M., Bauer, A., König, K., Bückle, R., Fluhr, J. W., & Kaatz, M. (2008) · Experimental Dermatology · doi:10.1111/j.1600-0625.2007.00669.x · Cited by 109 · cited 1×
“Various studies on tissue engineering (Schenke-Layland et al., 2006), in vivo drug monitoring (Koenig et al., 2006), skin aging (Koehler et al., 2008) as well as dermatological disorders (Riemann et al., 2005; Paoli et al., 2008) underline the excellent imaging capabilities.”
Self-citationMasters, B. R., & So, P. T. C. (1999) · Microscopy and Microanalysis · doi:10.1017/s1431927699990311 · Cited by 71 · cited 1×
“Endogenous fluorophores such as NAD(P)H (nicotinamide adenine dinucleotide (phosphate)) coenzymes, flavins, metal-free porphyrins, lipofuscin, melanin, elastin, collagen, and keratin are the primary source of tissue fluorescence (Masters and So, 1999; Koenig and Riemann, 2003; Zipfel et al., 2003).”
Cited by
Second harmonic generation microscopy for quantitative analysis of collagen fibrillar structure
Chen, X., Nadiarynkh, O., Plotnikov, S., & Campagnola, P. J. (2012) · Nature Protocols · doi:10.1038/nprot.2012.009 · Cited by 985
Light in diagnosis, therapy and surgery
Yun, S. H., & Kwok, S. J. J. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0008 · Cited by 793
Fluorescence Lifetime Techniques in Medical Applications
Marcu, L. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0495-y · Cited by 257
Reflectance confocal microscopy of skin in vivo: From bench to bedside
Rajadhyaksha, M., Marghoob, A., Rossi, A., Halpern, A. C., & Nehal, K. S. (2017) · Lasers in Surgery and Medicine · doi:10.1002/lsm.22600 · Cited by 222
“Two-photonmicroscopy (DermaInspect) provides exquisite specificity of contrast, and can detect melanocytic lesions with sensitivity of 71–76% and specificity of 97–72% [38].”
BackgroundScoring of collagen organization in healthy and diseased human dermis by multiphoton microscopy
Cicchi, R., Kapsokalyvas, D., De Giorgi, V., Maio, V., Van Wiechen, A., Massi, D., Lotti, T., & Pavone, F. S. (2010) · Journal of Biophotonics · doi:10.1002/jbio.200910062 · Cited by 209
Metadata
- Authors
- Dimitrow, E., Ziemer, M., Koehler, M. J., Norgauer, J., König, K., Elsner, P., & Kaatz, M.
- Venue
- Journal of Investigative Dermatology
- Publisher
- Elsevier BV
- Published
- 2009-07
- Volume
- 129
- Issue
- 7
- Pages
- 1752-1758
- ISSN
- 0022-202X (ISSN-L)
- OpenAlex
- W2074457543
- Cited by
- 242
- References
- 22
- FWCI
- 9.25
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.