The DOI matches its Crossref record.
High-resolution multiphoton tomography of human skin with subcellular spatial resolution and picosecond time resolution
Open accessAbstract
High-resolution four-dimensional (4-D) optical tomography of human skin based on multiphoton autofluorescence imaging and second harmonic generation (SHG) was performed with the compact femtosecond laser imaging system DermaInspect as well as a modified multiphoton microscope. Femtosecond laser pulses of 80 MHz in the spectral range of 750 to 850 nm, fast galvoscan mirrors, and a time-correlated single-photon counting module have been used to image human skin in vitro and in vivo with subcellular spatial and 250-ps temporal resolution. The nonlinear induced autofluorescence originates from naturally endogenous fluorophores and protein structures such as reduced nicotinamide adenine dinucleotide phosphate, flavins, collagen, elastin, porphyrins, and melanin. Second harmonic generation was used to detect collagen structures. Tissues of patients with dermatological disorders such as psoriasis, fungal infections, nevi, and melanomas have been investigated. Individual intratissue cells and skin structures could be clearly visualized. Intracellular components and connective tissue structures could be further characterized by fluorescence excitation spectra, by determination of the fluorescence decay per pixel, and by fluorescence lifetime imaging. The novel noninvasive multiphoton autofluorescence-SHG imaging technique provides 4-D (x,y,z,tau) optical biopsies with subcellular resolution and offers the possibility of introducing a high-resolution optical diagnostic method in dermatology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The physical and chemical properties of eumelanin
Meredith, P., & Sarna, T. (2006) · Pigment Cell Research · doi:10.1111/j.1600-0749.2006.00345.x · Cited by 1,033
Fluorescence lifetime imaging – techniques and applications
BECKER, W. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03618.x · Cited by 890
Schenke-Layland, K., Vasilevski, O., Opitz, F., König, K., Riemann, I., Halbhuber, K. J., Wahlers, T., & Stock, U. A. (2003) · Journal of Structural Biology · doi:10.1016/j.jsb.2003.08.002 · Cited by 302
Self-citationLabel-free DNA imaging in vivo with stimulated Raman scattering microscopy
Lu, F.-K., Basu, S., Igras, V., Hoang, M. P., Ji, M., Fu, D., Holtom, G. R., Neel, V. A., Freudiger, C. W., Fisher, D. E., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1515121112 · Cited by 302
In vivo assessment of human skin aging by multiphoton laser scanning tomography
Koehler, M. J., König, K., Elsner, P., Bückle, R., & Kaatz, M. (2006) · Optics Letters · doi:10.1364/ol.31.002879 · Cited by 280
Metadata
- Authors
- Koenig, K., & Riemann, I.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2003
- Volume
- 8
- Issue
- 3
- Pages
- 432
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2069562633
- Cited by
- 535
- References
- 0
- FWCI
- 13.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-resolution multiphoton tomography of human skin with subcellular spatial resolution and picosecond time resolution. https://app.cochat.ai/papers/10.1117/1.1577349
- The paper
- Koenig, K., & Riemann, I. (2003). High-resolution multiphoton tomography of human skin with subcellular spatial resolution and picosecond time resolution. Journal of Biomedical Optics. https://doi.org/10.1117/1.1577349
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.