The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Pixel super-resolution using wavelength scanning
Open accessAbstract
Undersampling and pixelation affect a number of imaging systems, limiting the resolution of the acquired images, which becomes particularly significant for wide-field microscopy applications. Various super-resolution techniques have been implemented to mitigate this resolution loss by utilizing sub-pixel displacements in the imaging system, achieved, for example, by shifting the illumination source, the sensor array and/or the sample, followed by digital synthesis of a smaller effective pixel by merging these sub-pixel-shifted low-resolution images. Herein, we introduce a new pixel super-resolution method that is based on wavelength scanning and demonstrate that as an alternative to physical shifting/displacements, wavelength diversity can be used to boost the resolution of a wide-field imaging system and significantly increase its space-bandwidth product. We confirmed the effectiveness of this new technique by improving the resolution of lens-free as well as lens-based microscopy systems and developed an iterative algorithm to generate high-resolution reconstructions of a specimen using undersampled diffraction patterns recorded at a few wavelengths covering a narrow spectrum (10–30 nm). When combined with a synthetic-aperture-based diffraction imaging technique, this wavelength-scanning super-resolution approach can achieve a half-pitch resolution of 250 nm, corresponding to a numerical aperture of ~1.0, across a large field of view (>20 mm2). We also demonstrated the effectiveness of this approach by imaging various biological samples, including blood and Papanicolaou smears. Compared with displacement-based super-resolution techniques, wavelength scanning brings uniform resolution improvement in all directions across a sensor array and requires significantly fewer measurements. This technique would broadly benefit wide-field imaging applications that demand larger space-bandwidth products. A new way to obtain high-resolution images over wide fields of view that involves scanning the wavelength has been demonstrated by a US team. The resolution of many imaging systems, particularly wide-field microscopes, is limited by undersampling and pixelation. Conventionally, this problem has been remedied by physically shifting the light source, sample or detector. Now, Aydogan Ozcan and co-workers at the University of California, Los Angeles propose a new solution—successively illuminating the sample at a few wavelengths over a narrow range (10–30 nanometres). This method has two main advantages over physical scanning: it requires fewer measurements and results in uniform enhancement of the resolution over the entire sample plane. The researchers experimentally demonstrate the technique on both lens-based imaging systems and lensless holographic ones.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phase contrast, a new method for the microscopic observation of transparent objects
Zernike, F. (1942) · Physica · doi:10.1016/s0031-8914(42)80035-x · Cited by 1,068
Cited by
Phase recovery and holographic image reconstruction using deep learning in neural networks
Rivenson, Y., Zhang, Y., Günaydın, H., Teng, D., & Ozcan, A. (2017) · Light: Science & Applications · doi:10.1038/lsa.2017.141 · Cited by 1,059
Self-citationTransport of intensity equation: a tutorial
Zuo, C., Li, J., Sun, J., Fan, Y., Zhang, J., Lu, L., Zhang, R., Wang, B., Huang, L., & Chen, Q. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106187 · Cited by 581
Wasisto, H. S., Prades, J. D., Gülink, J., & Waag, A. (2019) · Applied Physics Reviews · doi:10.1063/1.5096322 · Cited by 309
Wu, Y., & Ozcan, A. (2018) · Methods · doi:10.1016/j.ymeth.2017.08.013 · Cited by 260
Self-citationGӧrӧcs, Z., Tamamitsu, M., Bianco, V., Wolf, P., Roy, S., Shindo, K., Yanny, K., Wu, Y., Koydemir, H. C., Rivenson, Y., et al. (2018) · Light: Science & Applications · doi:10.1038/s41377-018-0067-0 · Cited by 188
Self-citation
Metadata
- Authors
- Luo, W., Zhang, Y., Feizi, A., Göröcs, Z., & Ozcan, A.
- Venue
- Light: Science & Applications
- Published
- 2015-12-14
- Volume
- 5
- Issue
- 4
- Pages
- e16060-e16060
- ISSN
- 2047-7538 (ISSN-L)
- OpenAlex
- W2315813075
- Cited by
- 214
- References
- 1
- FWCI
- 15.60
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.