The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Parallel droplet microfluidics for high throughput cell encapsulation and synthetic microgel generation
Open accessAbstract
Cells can be microencapsulated in synthetic hydrogel microspheres (microgels) using droplet microfluidics, but microfluidic devices with a single droplet generating geometry have limited throughput, especially as microgel diameter decreases. Here we demonstrate microencapsulation of human mesenchymal stem cells (hMSCs) in small (<100 μm diameter) microgels utilizing parallel droplet generators on a two-layer elastomer device, which has 600% increased throughput vs. single-nozzle devices. Distribution of microgel diameters were compared between products of parallel vs. single-nozzle configurations for two square nozzle widths, 35 and 100 μm. Microgels produced on parallel nozzles were equivalent to those produced on single nozzles, with substantially the same polydispersity. Microencapsulation of hMSCs was compared for parallel nozzle devices of each width. Thirty five micrometer wide nozzle devices could be operated at twice the cell concentration of 100 μm wide nozzle devices but produced more empty microgels than predicted by a Poisson distribution. Hundred micrometer wide nozzle devices produced microgels as predicted by a Poisson distribution. Polydispersity of microgels did not increase with the addition of cells for either nozzle width. hMSCs encapsulated on 35 μm wide nozzle devices had reduced viability (~70%) and a corresponding decrease in vascular endothelial growth factor (VEGF) secretion compared to hMSCs cultured on tissue culture (TC) plastic. Encapsulating hMSCs using 100 μm wide nozzle devices mitigated loss of viability and function, as measured by VEGF secretion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The biology of VEGF and its receptors
Ferrara, N., Gerber, H.-P., & LeCouter, J. (2003) · Nature Medicine · doi:10.1038/nm0603-669 · Cited by 9,591
Lutolf, M. P., & Hubbell, J. A. (2005) · Nature Biotechnology · doi:10.1038/nbt1055 · Cited by 4,551
Vegas, A. J., Veiseh, O., Gürtler, M., Millman, J. R., Pagliuca, F. W., Bader, A. R., Doloff, J. C., Li, J., Chen, M., Olejnik, K., et al. (2016) · Nature Medicine · doi:10.1038/nm.4030 · Cited by 710
Cited by
Hydrogel microparticles for biomedical applications
Daly, A. C., Riley, L., Segura, T., & Burdick, J. A. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0148-6 · Cited by 1,249
Recent Advances in Droplet Microfluidics
Ding, Y., Howes, P. D., & deMello, A. J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05047 · Cited by 357
Metadata
- Authors
- Headen, D. M., García, J. R., & García, A. J.
- Venue
- Microsystems & Nanoengineering
- Published
- 2018-01-15
- Volume
- 4
- Issue
- 1
- ISSN
- 2055-7434 (ISSN-L)
- OpenAlex
- W2783089403
- Cited by
- 159
- References
- 3
- FWCI
- 6.32
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.