The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Chemical identification of individual surface atoms by atomic force microscopy
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Positioning single atoms with a scanning tunnelling microscope
Eigler, D. M., & Schweizer, E. K. (1990) · Nature · doi:10.1038/344524a0 · Cited by 3,161
Frequency modulation detection using high-Q cantilevers for enhanced force microscope sensitivity
Albrecht, T. R., Grütter, P., Horne, D., & Rugar, D. (1991) · Journal of Applied Physics · doi:10.1063/1.347347 · Cited by 2,434
Advances in atomic force microscopy
Giessibl, F. J. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.949 · Cited by 2,278
Dynamic atomic force microscopy methods
García, R. (2002) · Surface Science Reports · doi:10.1016/s0167-5729(02)00077-8 · Cited by 2,076
Single-Molecule Vibrational Spectroscopy and Microscopy
Stipe, B. C., Rezaei, M. A., & Ho, W. (1998) · Science · doi:10.1126/science.280.5370.1732 · Cited by 1,384
Tunneling into a Single Magnetic Atom: Spectroscopic Evidence of the Kondo Resonance
Madhavan, V., Chen, W., Jamneala, T., Crommie, M. F., & Wingreen, N. S. (1998) · Science · doi:10.1126/science.280.5363.567 · Cited by 1,030
Accurate formulas for interaction force and energy in frequency modulation force spectroscopy
Sader, J. E., & Jarvis, S. P. (2004) · Applied Physics Letters · doi:10.1063/1.1667267 · Cited by 703
Kondo Scattering Observed at a Single Magnetic Impurity
Li, J., Schneider, W.-D., Berndt, R., & Delley, B. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.2893 · Cited by 643
Noncontact Atomic Force Microscopy
(2002) · NanoScience and Technology · doi:10.1007/978-3-642-56019-4 · Cited by 507
Cited by
Direct mapping of the solid–liquid adhesion energy with subnanometre resolution
Voïtchovsky, K., Kuna, J. J., Contera, S. A., Tosatti, E., & Stellacci, F. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.67 · Cited by 194
Surface point defects on bulk oxides: atomically-resolved scanning probe microscopy
Setvín, M., Wagner, M., Schmid, M., Parkinson, G. S., & Diebold, U. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00076f · Cited by 134
Atomic-resolution three-dimensional hydration structures on a heterogeneously charged surface
Umeda, K., Zivanovic, L., Kobayashi, K., Ritala, J., Kominami, H., Spijker, P., Foster, A. S., & Yamada, H. (2017) · Nature Communications · doi:10.1038/s41467-017-01896-4 · Cited by 85
Metadata
- Authors
- Sugimoto, Y., Pou, P., Abe, M., Jelinek, P., Pérez, R., Morita, S., & Custance, Ó.
- Venue
- Nature
- Published
- 2007-03
- Volume
- 446
- Issue
- 7131
- Pages
- 64-67
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2010963801
- Cited by
- 772
- References
- 16
- FWCI
- 36.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chemical identification of individual surface atoms by atomic force microscopy. https://app.cochat.ai/papers/10.1038/nature05530
- The paper
- Sugimoto, Y., Pou, P., Abe, M., Jelinek, P., Pérez, R., Morita, S., & Custance, Ó. (2007). Chemical identification of individual surface atoms by atomic force microscopy. Nature. https://doi.org/10.1038/nature05530
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.