The DOI matches its Crossref record; 52 of the 53 references it cites were found in a registry or an index.
Magnetic resonance fingerprinting
Open accessAbstract
Magnetic resonance is an exceptionally powerful and versatile measurement technique. The basic structure of a magnetic resonance experiment has remained largely unchanged for almost 50 years, being mainly restricted to the qualitative probing of only a limited set of the properties that can in principle be accessed by this technique. Here we introduce an approach to data acquisition, post-processing and visualization--which we term 'magnetic resonance fingerprinting' (MRF)--that permits the simultaneous non-invasive quantification of multiple important properties of a material or tissue. MRF thus provides an alternative way to quantitatively detect and analyse complex changes that can represent physical alterations of a substance or early indicators of disease. MRF can also be used to identify the presence of a specific target material or tissue, which will increase the sensitivity, specificity and speed of a magnetic resonance study, and potentially lead to new diagnostic testing methodologies. When paired with an appropriate pattern-recognition algorithm, MRF inherently suppresses measurement errors and can thus improve measurement accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It uses a pseudo-randomized acquisition that causes the signals from different tissues to have a unique signal evolution ('fingerprint') that is a function of the multiple material properties being investigated.”
From An overview of deep learning in medical imaging focusing on MRI (2019) · cites this paper as [150]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,703
Turk, M., & Pentland, A. (1991) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1991.3.1.71 · Cited by 13,733
Signal Recovery From Random Measurements Via Orthogonal Matching Pursuit
Tropp, J. A., & Gilbert, A. C. (2007) · IEEE Transactions on Information Theory · doi:10.1109/tit.2007.909108 · Cited by 9,715
Robust Face Recognition via Sparse Representation
Wright, J. N., Yang, A., Ganesh, A., Sastry, S., & Ma, Y. (2009) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2008.79 · Cited by 9,398
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Near-Optimal Signal Recovery From Random Projections: Universal Encoding Strategies?
Candès, E. J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.885507 · Cited by 6,809
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellús̆, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,311
Face recognition using eigenfaces
Turk, M., & Pentland, A. (2002) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.1991.139758 · Cited by 5,262
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,089
CoSaMP: Iterative signal recovery from incomplete and inaccurate samples
Needell, D., & Tropp, J. A. (2008) · Applied and Computational Harmonic Analysis · doi:10.1016/j.acha.2008.07.002 · Cited by 4,449
The Split Bregman Method for L1-Regularized Problems
Goldstein, T., & Osher, S. (2009) · SIAM Journal on Imaging Sciences · doi:10.1137/080725891 · Cited by 4,310
Perlin, K. (1985) · ACM SIGGRAPH Computer Graphics · doi:10.1145/325165.325247 · Cited by 2,207
Nonuniform fast fourier transforms using min-max interpolation
Fessler, J. A., & Sutton, B. P. (2003) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2002.807005 · Cited by 1,343
Iteratively reweighted algorithms for compressive sensing
Chartrand, R., & Yin, W. (2008) · 2008 IEEE International Conference on Acoustics, Speech and Signal Processing · doi:10.1109/icassp.2008.4518498 · Cited by 1,248
In vivo measurement of T 2 distributions and water contents in normal human brain
Whittall, K. P., MacKay, A. L., Graeb, D. A., Nugent, R. A., Li, D. K. B., & Paty, D. W. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370107 · Cited by 796
Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state
Deoni, S., Rutt, B. K., & Peters, T. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10407 · Cited by 745
Principles and applications of balanced SSFP techniques
Scheffler, K., & Lehnhardt, S. (2003) · European Radiology · doi:10.1007/s00330-003-1957-x · Cited by 714
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · Wiley eBooks · doi:10.1002/9781118633953 · Cited by 545
Rapid magnetic resonance quantification on the brain: Optimization for clinical usage
Warntjes, J. B. M., Leinhard, O. D., West, J., & Lundberg, P. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21635 · Cited by 502
Deoni, S., Peters, T. M., & Rutt, B. K. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20314 · Cited by 482
MR fingerprinting using fast imaging with steady state precession (FISP) with spiral readout
Jiang, Y., Ma, D., Seiberlich, N., Gulani, V., & Griswold, M. A. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25559 · Cited by 422
Practical T2 quantitation for clinical applications
Poon, C. S., & Henkelman, R. M. (1992) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880020512 · Cited by 396
Vymazal, J., Righini, A., Brooks, R. A., Canesi, M., Mariani, C. B., Leonardi, M., & Pezzoli, G. (1999) · Radiology · doi:10.1148/radiology.211.2.r99ma53489 · Cited by 341
Compressed sensing reconstruction for magnetic resonance parameter mapping
Doneva, M., Börnert, P., Eggers, H., Stehning, C., Sénégas, J., & Mertins, A. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22483 · Cited by 326
Compressed-Sensing MRI With Random Encoding
Haldar, J. P., Hernando, D., & Liang, Z. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2085084 · Cited by 310
Barger, A. V., Block, W. F., Toropov, Y., Grist, T. M., & Mistretta, C. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10212 · Cited by 291
Inversion recovery TrueFISP: Quantification of T 1 , T 2 , and spin density
Schmitt, P., Griswold, M. A., Jakob, P. M., Kotas, M., Gulani, V., Flentje, M. P., & Haase, A. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20058 · Cited by 242
In Vivo Evaluation of Brain Iron in Alzheimer Disease Using Magnetic Resonance Imaging
Bartzokis, G., Sultzer, D. L., Cummings, J. L., Holt, L. E., Hance, D. B., Henderson, V. W., & Mintz, J. (2000) · Archives of General Psychiatry · doi:10.1001/archpsyc.57.1.47 · Cited by 235
Novel method for rapid, simultaneous T 1 , T * 2 , and proton density quantification
Warntjes, J. B. M., Dahlqvist, O. L., & Lundberg, P. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21165 · Cited by 219
A comparison of one‐shot and recovery methods in T1 imaging
Crawley, A. P., & Henkelman, R. M. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910070104 · Cited by 199
Water diffusion, T2, and compartmentation in frog sciatic nerve
Peled, S., Cory, D. G., Raymond, S. A., Kirschner, D. A., & Jolesz, F. A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5 · Cited by 193
Larsson, H. B. W., Frederiksen, J. L., Petersen, J. H., Nordenbo, A. M., Zeeberg, I., Henriksen, O. M., & Olesen, J. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910110308 · Cited by 158
Magnetic resonance with stochastic excitation
Ernst, R. R. (1970) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(70)90004-1 · Cited by 149
Multi‐contrast reconstruction with Bayesian compressed sensing
Bilgiç, B., Goyal, V. K., & Adalsteinsson, E. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22956 · Cited by 146
Prospective multiaxial motion correction for fMRI
Ward, H. A., Riederer, S. J., Grimm, R. C., Ehman, R. L., Felmlee, J. P., & Jack, C. R. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200003)43:3 · Cited by 132
Improved radial GRAPPA calibration for real‐time free‐breathing cardiac imaging
Seiberlich, N., Ehses, P., Duerk, J. L., Gilkeson, R., & Griswold, M. A. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22618 · Cited by 105
Ehses, P., Seiberlich, N., Ma, D., Breuer, F., Jakob, P. M., Griswold, M. A., & Gulani, V. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24225 · Cited by 103
Deshpande, V. S., Chung, Y., Zhang, Q., Shea, S. M., & Li, D. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10337 · Cited by 101
Fast 3D imaging using variable‐density spiral trajectories with applications to limb perfusion
Lee, J. H., Hargreaves, B. A., Hu, B. S., & Nishimura, D. G. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10644 · Cited by 100
Direct parallel image reconstructions for spiral trajectories using GRAPPA
Heidemann, R. M., Griswold, M. A., Seiberlich, N., Krüger, G., Kannengießer, S., Kiefer, B., Wiggins, G. C., Wald, L. L., & Jakob, P. M. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20951 · Cited by 95
Williamson, P., Pelz, D. M., Merskey, H., Morrison, S., Karlik, S. J., Drost, D. J., Carr, T. J., & Conlon, P. (1992) · American Journal of Psychiatry · doi:10.1176/ajp.149.4.549 · Cited by 76
Pitkänen, A., Laakso, M. P., Kälviäinen, R. K., Partanen, K. P. L., Vainio, P. A., Lehtovirta, M., Riekkinen, P. J., & Soininen, H. S. (1996) · Neurology · doi:10.1212/wnl.46.6.1724 · Cited by 73
Time‐optimal multidimensional gradient waveform design for rapid imaging
Hargreaves, B. A., Nishimura, D. G., & Conolly, S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10666 · Cited by 69
Nayak, K. S., Lee, H., Hargreaves, B. A., & Hu, B. S. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21296 · Cited by 67
Frequency resolved single‐shot MR imaging using stochastic k ‐space trajectories
Scheffler, K., & Hennig, J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350417 · Cited by 59
Nonuniform Phase-Encode Distributions for MRI Scan Time Reduction
Marseille, G. J., de Beer, R., Fuderer, M., Mehlkopf, A. F., & ORMONDT, D. V. (1996) · Journal of Magnetic Resonance Series B · doi:10.1006/jmrb.1996.0061 · Cited by 54
A simple geometrical description of the TrueFISP ideal transient and steady‐state signal
Schmitt, P., Griswold, M. A., Gulani, V., Haase, A., Flentje, M. P., & Jakob, P. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20738 · Cited by 41
Multiple repetition time balanced steady‐state free precession imaging
Çukur, T., & Nishimura, D. G. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21990 · Cited by 30
Smith, D. S., Li, X., Gambrell, J. V., Arlinghaus, L. R., Quarles, C. C., Yankeelov, T. E., & Welch, E. B. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2172216 · Cited by 29
Lee, K. J., Lee, H., Hennig, J., & Leupold, J. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23221 · Cited by 7
Research works printed but not linked: 4
- Stoecker, T., Vahedipour, K., Pracht, E., Brenner, D. & Shah, N. J. in Proc. 19th Scientific Meeting International Society for Magnetic Resonance in Medicine 381 (Int. Soc. Magn. Reson. Med., 2011)
- Davenport, M. A., Wakin, M. B. & Baraniuk, R. G. The Compressive Matched Filter (Tech. Rep. TREE 0610, Rice University, 2006)
- Chartrand, R. & Yin, W. in Proc. ICASSP 2008 IEEE International Conference 3869–3872 (IEEE, 2008)
- Riffe, M. J., Blaimer, M., Barkauskas, K. J., Duerk, J. L. & Griswold, M. A. in Proc. 15th Scientific Meeting, International Society for Magnetic Resonance in Medicine 1879 (Int. Soc. Magn. Reson. Med, 2007)
Cited by
Sorted by citations
An overview of deep learning in medical imaging focusing on MRI
Lundervold, A. S., & Lundervold, A. (2019) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2018.11.002 · Cited by 2,058
An overview of deep learning in medical imaging focusing on MRI
Lundervold, A. S., & Lundervold, A. (2018) · NORA - Norwegian Open Research Archives · Cited by 1,012
AI applications to medical images: From machine learning to deep learning
Castiglioni, I., Rundo, L., Codari, M., Leo, G. D., Salvatore, C., Interlenghi, M., Gallivanone, F., Cozzi, A., D’Amico, N. C., & Sardanelli, F. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.02.006 · Cited by 779
A probabilistic atlas of the human thalamic nuclei combining ex vivo MRI and histology
Iglesias, J. E., Insausti, R., Lerma‐Usabiaga, G., Bocchetta, M., Leemput, K. V., Greve, D. N., van der Kouwe, A. J. W., Fischl, B. R., Caballero‐Gaudes, C., & Paz‐Alonso, P. M. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.08.012 · Cited by 575
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiß, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 586
Metadata
- Authors
- Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A.
- Affiliations
- Case Western Reserve University (US)
- University Hospitals of Cleveland (US)
- Siemens Healthcare (United States) (US)
- Corresponding author
- Griswold, Mark A.
- ORCID
- Venue
- Nature
- Published
- 2013-03
- Volume
- 495
- Issue
- 7440
- Pages
- 187-192
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- PMC
- PMC3602925
- OpenAlex
- W2144288697
- Cited by
- 1,577
- References
- 53
- Citations by year
- 2026: 115 · 2025: 147 · 2024: 148 · 2023: 160 · 2022: 149 · 2021: 175 · 2020: 168 · 2019: 157 · 2018: 108 · 2017: 101 · 2016: 65 · 2015: 42 · 2014: 26 · 2013: 10
- FWCI
- 36.92
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- OhioLink ETD Center (Ohio Library and Information Network) (submittedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Funders
- Agence Nationale de la Recherche (ANR-20-CE19-0030, ANR-11-INBS-0006, ANR-21-CE17-0028)
- National Institutes of Health (KL2TR000440)
- National Heart, Lung, and Blood Institute (R01HL094557)
- National Center for Advancing Translational Sciences
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Keywords
- magnetic resonance fingerprinting, quantitative MRI, pattern recognition, tissue characterization, disease detection, non-invasive measurement, nuclear magnetic resonance
- MeSH terms
- Algorithms, Diagnostic Tests, Routine, Humans, Motion, Magnetic Resonance Spectroscopy, Pattern Recognition, Automated, Research Design, Sensitivity and Specificity, Reproducibility of Results, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review