The DOI matches its Crossref record; 52 of the 53 references it cites were found in a registry or an index.
Magnetic resonance fingerprinting
Open accessAbstract
Magnetic resonance is an exceptionally powerful and versatile measurement technique. The basic structure of a magnetic resonance experiment has remained largely unchanged for almost 50 years, being mainly restricted to the qualitative probing of only a limited set of the properties that can in principle be accessed by this technique. Here we introduce an approach to data acquisition, post-processing and visualization--which we term 'magnetic resonance fingerprinting' (MRF)--that permits the simultaneous non-invasive quantification of multiple important properties of a material or tissue. MRF thus provides an alternative way to quantitatively detect and analyse complex changes that can represent physical alterations of a substance or early indicators of disease. MRF can also be used to identify the presence of a specific target material or tissue, which will increase the sensitivity, specificity and speed of a magnetic resonance study, and potentially lead to new diagnostic testing methodologies. When paired with an appropriate pattern-recognition algorithm, MRF inherently suppresses measurement errors and can thus improve measurement accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It uses a pseudo-randomized acquisition that causes the signals from different tissues to have a unique signal evolution ('fingerprint') that is a function of the multiple material properties being investigated.”
From An overview of deep learning in medical imaging focusing on MRI (2019) · cites this paper as [150]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,703
Turk, M., & Pentland, A. (1991) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1991.3.1.71 · Cited by 13,733
Signal Recovery From Random Measurements Via Orthogonal Matching Pursuit
Tropp, J. A., & Gilbert, A. C. (2007) · IEEE Transactions on Information Theory · doi:10.1109/tit.2007.909108 · Cited by 9,715
Robust Face Recognition via Sparse Representation
Wright, J. N., Yang, A., Ganesh, A., Sastry, S., & Ma, Y. (2009) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2008.79 · Cited by 9,398
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Near-Optimal Signal Recovery From Random Projections: Universal Encoding Strategies?
Candès, E. J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.885507 · Cited by 6,809
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellús̆, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,311
Face recognition using eigenfaces
Turk, M., & Pentland, A. (2002) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.1991.139758 · Cited by 5,262
Research works printed but not linked: 4
- Stoecker, T., Vahedipour, K., Pracht, E., Brenner, D. & Shah, N. J. in Proc. 19th Scientific Meeting International Society for Magnetic Resonance in Medicine 381 (Int. Soc. Magn. Reson. Med., 2011)
- Davenport, M. A., Wakin, M. B. & Baraniuk, R. G. The Compressive Matched Filter (Tech. Rep. TREE 0610, Rice University, 2006)
- Chartrand, R. & Yin, W. in Proc. ICASSP 2008 IEEE International Conference 3869–3872 (IEEE, 2008)
- Riffe, M. J., Blaimer, M., Barkauskas, K. J., Duerk, J. L. & Griswold, M. A. in Proc. 15th Scientific Meeting, International Society for Magnetic Resonance in Medicine 1879 (Int. Soc. Magn. Reson. Med, 2007)
Cited by
Sorted by citations
An overview of deep learning in medical imaging focusing on MRI
Lundervold, A. S., & Lundervold, A. (2019) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2018.11.002 · Cited by 2,058
An overview of deep learning in medical imaging focusing on MRI
Lundervold, A. S., & Lundervold, A. (2018) · NORA - Norwegian Open Research Archives · Cited by 1,012
AI applications to medical images: From machine learning to deep learning
Castiglioni, I., Rundo, L., Codari, M., Leo, G. D., Salvatore, C., Interlenghi, M., Gallivanone, F., Cozzi, A., D’Amico, N. C., & Sardanelli, F. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.02.006 · Cited by 779
A probabilistic atlas of the human thalamic nuclei combining ex vivo MRI and histology
Iglesias, J. E., Insausti, R., Lerma‐Usabiaga, G., Bocchetta, M., Leemput, K. V., Greve, D. N., van der Kouwe, A. J. W., Fischl, B. R., Caballero‐Gaudes, C., & Paz‐Alonso, P. M. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.08.012 · Cited by 575
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiß, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 586
Metadata
- Authors
- Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A.
- Affiliations
- Case Western Reserve University (US)
- University Hospitals of Cleveland (US)
- Siemens Healthcare (United States) (US)
- Corresponding author
- Griswold, Mark A.
- ORCID
- Venue
- Nature
- Published
- 2013-03
- Volume
- 495
- Issue
- 7440
- Pages
- 187-192
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- PMC
- PMC3602925
- OpenAlex
- W2144288697
- Cited by
- 1,577
- References
- 53
- Citations by year
- 2026: 115 · 2025: 147 · 2024: 148 · 2023: 160 · 2022: 149 · 2021: 175 · 2020: 168 · 2019: 157 · 2018: 108 · 2017: 101 · 2016: 65 · 2015: 42 · 2014: 26 · 2013: 10
- FWCI
- 36.92
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- OhioLink ETD Center (Ohio Library and Information Network) (submittedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Funders
- Agence Nationale de la Recherche (ANR-20-CE19-0030, ANR-11-INBS-0006, ANR-21-CE17-0028)
- National Institutes of Health (KL2TR000440)
- National Heart, Lung, and Blood Institute (R01HL094557)
- National Center for Advancing Translational Sciences
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Keywords
- magnetic resonance fingerprinting, quantitative MRI, pattern recognition, tissue characterization, disease detection, non-invasive measurement, nuclear magnetic resonance
- MeSH terms
- Algorithms, Diagnostic Tests, Routine, Humans, Motion, Magnetic Resonance Spectroscopy, Pattern Recognition, Automated, Research Design, Sensitivity and Specificity, Reproducibility of Results, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review