The DOI matches its Crossref record; 52 of the 53 references it cites were found in a registry or an index.
Magnetic resonance fingerprinting
Open accessAbstract
Magnetic resonance is an exceptionally powerful and versatile measurement technique. The basic structure of a magnetic resonance experiment has remained largely unchanged for almost 50 years, being mainly restricted to the qualitative probing of only a limited set of the properties that can in principle be accessed by this technique. Here we introduce an approach to data acquisition, post-processing and visualization--which we term 'magnetic resonance fingerprinting' (MRF)--that permits the simultaneous non-invasive quantification of multiple important properties of a material or tissue. MRF thus provides an alternative way to quantitatively detect and analyse complex changes that can represent physical alterations of a substance or early indicators of disease. MRF can also be used to identify the presence of a specific target material or tissue, which will increase the sensitivity, specificity and speed of a magnetic resonance study, and potentially lead to new diagnostic testing methodologies. When paired with an appropriate pattern-recognition algorithm, MRF inherently suppresses measurement errors and can thus improve measurement accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It uses a pseudo-randomized acquisition that causes the signals from different tissues to have a unique signal evolution ('fingerprint') that is a function of the multiple material properties being investigated.”
From An overview of deep learning in medical imaging focusing on MRI (2019) · cites this paper as [150]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,703
Turk, M., & Pentland, A. (1991) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1991.3.1.71 · Cited by 13,733
Signal Recovery From Random Measurements Via Orthogonal Matching Pursuit
Tropp, J. A., & Gilbert, A. C. (2007) · IEEE Transactions on Information Theory · doi:10.1109/tit.2007.909108 · Cited by 9,715
Robust Face Recognition via Sparse Representation
Wright, J. N., Yang, A., Ganesh, A., Sastry, S., & Ma, Y. (2009) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2008.79 · Cited by 9,398
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Near-Optimal Signal Recovery From Random Projections: Universal Encoding Strategies?
Candès, E. J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.885507 · Cited by 6,809
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellús̆, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,311
Face recognition using eigenfaces
Turk, M., & Pentland, A. (2002) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.1991.139758 · Cited by 5,262
Flagged first, then by citations
1 of the 53 references couldn’t be matched to a known paper.
Research works printed but not linked: 4
- Stoecker, T., Vahedipour, K., Pracht, E., Brenner, D. & Shah, N. J. in Proc. 19th Scientific Meeting International Society for Magnetic Resonance in Medicine 381 (Int. Soc. Magn. Reson. Med., 2011)
- Davenport, M. A., Wakin, M. B. & Baraniuk, R. G. The Compressive Matched Filter (Tech. Rep. TREE 0610, Rice University, 2006)
- Chartrand, R. & Yin, W. in Proc. ICASSP 2008 IEEE International Conference 3869–3872 (IEEE, 2008)
- Riffe, M. J., Blaimer, M., Barkauskas, K. J., Duerk, J. L. & Griswold, M. A. in Proc. 15th Scientific Meeting, International Society for Magnetic Resonance in Medicine 1879 (Int. Soc. Magn. Reson. Med, 2007)
Cited by
Sorted by citations
An overview of deep learning in medical imaging focusing on MRI
Lundervold, A. S., & Lundervold, A. (2019) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2018.11.002 · Cited by 2,058
An overview of deep learning in medical imaging focusing on MRI
Lundervold, A. S., & Lundervold, A. (2018) · NORA - Norwegian Open Research Archives · Cited by 1,012
AI applications to medical images: From machine learning to deep learning
Castiglioni, I., Rundo, L., Codari, M., Leo, G. D., Salvatore, C., Interlenghi, M., Gallivanone, F., Cozzi, A., D’Amico, N. C., & Sardanelli, F. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.02.006 · Cited by 779
A probabilistic atlas of the human thalamic nuclei combining ex vivo MRI and histology
Iglesias, J. E., Insausti, R., Lerma‐Usabiaga, G., Bocchetta, M., Leemput, K. V., Greve, D. N., van der Kouwe, A. J. W., Fischl, B. R., Caballero‐Gaudes, C., & Paz‐Alonso, P. M. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.08.012 · Cited by 575
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiß, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 586
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Advances in multimodal data fusion in neuroimaging: Overview, challenges, and novel orientation
Zhang, Y., Dong, Z., Wang, S., Yu, X., Yao, X., Zhou, Q., Hu, H., Li, M., Jiménez-Mesa, C., Ramı́rez, J., et al. (2020) · Information Fusion · doi:10.1016/j.inffus.2020.07.006 · Cited by 461
MR fingerprinting using fast imaging with steady state precession (FISP) with spiral readout
Jiang, Y., Ma, D., Seiberlich, N., Gulani, V., & Griswold, M. A. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25559 · Cited by 422
Shukla‐Dave, A., Obuchowski, N. A., Chenevert, T. L., Jambawalikar, S., Schwartz, L. H., Malyarenko, D. I., Huang, W., Noworolski, S. M., Young, R. J., Shiroishi, M. S., et al. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26518 · Cited by 399
Low‐field MRI: An MR physics perspective
Marques, J. P., Simonis, F. F. J., & WEBB, A. G. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26637 · Cited by 389
Novikov, D. S., Kiselev, V. G., & Jespersen, S. N. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27101 · Cited by 362
Molecular imaging in oncology: Current impact and future directions
Rowe, S. P., & Pomper, M. G. (2021) · CA A Cancer Journal for Clinicians · doi:10.3322/caac.21713 · Cited by 342
SVD Compression for Magnetic Resonance Fingerprinting in the Time Domain
McGivney, D., Pierre, E. Y., Ma, D., Jiang, Y., Saybasili, H., Gulani, V., & Griswold, M. A. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2337321 · Cited by 308
MR fingerprinting Deep RecOnstruction NEtwork (DRONE)
Cohen, O., Zhu, B., & Rosen, M. S. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27198 · Cited by 310
Compressed sensing for body MRI
Feng, L., Benkert, T., Block, K. T., Sodickson, D. K., Otazo, R., & Chandarana, H. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25547 · Cited by 306
Quantitative magnetic resonance imaging of brain anatomy and in vivo histology
Weiskopf, N., Edwards, L., Helms, G., Mohammadi, S., & Kirilina, E. P. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00326-1 · Cited by 321
Sarracanie, M., LaPierre, C., Salameh, N., Waddington, D. E. J., Witzel, T., & Rosen, M. S. (2015) · Scientific Reports · doi:10.1038/srep15177 · Cited by 298
Progressive multiple sclerosis: prospects for disease therapy, repair, and restoration of function
Ontaneda, D., Thompson, A. J., Fox, R. J., & Cohen, J. A. (2017) · The Lancet · doi:10.1016/s0140-6736(16)31320-4 · Cited by 298
Molecular Magnetic Resonance Imaging with Gd(III)-Based Contrast Agents: Challenges and Key Advances
Li, H., & Meade, T. J. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b09149 · Cited by 292
What are normal relaxation times of tissues at 3 T?
Bojorquez, J. Z., Bricq, S., Acquitter, C., Brunotte, F., Walker, P. M., & Lalande, A. (2017) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2016.08.021 · Cited by 286
Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging
Christodoulou, A. G., Shaw, J. L., Nguyen, C., Yang, Q., Xie, Y., Wang, N., & Li, D. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0217-y · Cited by 323
Graph-Based Deep Learning for Medical Diagnosis and Analysis: Past, Present and Future
Ahmedt‐Aristizabal, D., Armin, M. A., Denman, S., Fookes, C., & Petersson, L. (2021) · Sensors · doi:10.3390/s21144758 · Cited by 298
Psychoradiology: The Frontier of Neuroimaging in Psychiatry
Lui, S., Zhou, X. J., Sweeney, J. A., & Gong, Q. (2016) · Radiology · doi:10.1148/radiol.2016152149 · Cited by 276
A low-cost and shielding-free ultra-low-field brain MRI scanner
Liu, Y., Leong, A. T. L., Zhao, Y., Xiao, L., Mak, H. K., Tsang, A. C. O., Lau, G. K. K., Leung, G., & Wu, E. X. (2021) · Nature Communications · doi:10.1038/s41467-021-27317-1 · Cited by 267
MR fingerprinting for rapid quantification of myocardial T1, T2, and proton spin density
Hamilton, J., Jiang, Y., Chen, Y., Ma, D., Lo, W., Griswold, M. A., & Seiberlich, N. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26216 · Cited by 246
Accessible magnetic resonance imaging: A review
Geethanath, S., & Vaughan, J. T. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26638 · Cited by 245
Hagiwara, A., Warntjes, M. J. B., Hori, M., Andica, C., Nakazawa, M., Kumamaru, K. K., Abe, O., & Aoki, S. (2017) · Investigative Radiology · doi:10.1097/rli.0000000000000365 · Cited by 241
Hollingsworth, K. G. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/21/r297 · Cited by 238
Gagnon, L., Sakadžić, S., Lesage, F., Musacchia, J. J., Lefebvre, J., Fang, Q., Yücel, M. A., Evans, K. C., Mandeville, E. T., Cohen‐Adad, J., et al. (2015) · Journal of Neuroscience · doi:10.1523/jneurosci.3555-14.2015 · Cited by 236
Enhancement of Magnetic Resonance Imaging with Metasurfaces
Slobozhanyuk, A. P., Poddubny, A. N., Raaijmakers, A. J. E., van den Berg, C. A. T., Kozachenko, A. V., Дубровина, И. А., Мельчакова, И. В., Kivshar, Y. S., & Belov, P. A. (2016) · Advanced Materials · doi:10.1002/adma.201504270 · Cited by 241
Rapid and accurate T2 mapping from multi–spin‐echo data using Bloch‐simulation‐based reconstruction
Ben‐Eliezer, N., Sodickson, D. K., & Block, K. T. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25156 · Cited by 225
MR Fingerprinting for Rapid Quantitative Abdominal Imaging
Chen, Y., Jiang, Y., Pahwa, S. S., Ma, D., Lŭ, L., Twieg, M. D., Wright, K. L., Seiberlich, N., Griswold, M. A., & Gulani, V. (2016) · Radiology · doi:10.1148/radiol.2016152037 · Cited by 211
In Vivo Imaging of Human Neuroinflammation
Albrecht, D., Granziera, C., Hooker, J. M., & Loggia, M. L. (2016) · ACS Chemical Neuroscience · doi:10.1021/acschemneuro.6b00056 · Cited by 212
Low rank alternating direction method of multipliers reconstruction for MR fingerprinting
Assländer, J., Cloos, M. A., Knöll, F., Sodickson, D. K., Hennig, J., & Lattanzi, R. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26639 · Cited by 207
Lagendijk, J. J. W., Raaymakers, B. W., van den Berg, C. A. T., Moerland, M. A., Philippens, M. E. P., & van Vulpen, M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/21/r349 · Cited by 203
T 2 shuffling: Sharp, multicontrast, volumetric fast spin‐echo imaging
Tamir, J. I., Uecker, M., Chen, W., Lai, P., Alley, M. T., Vasanawala, S. S., & Lustig, M. S. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26102 · Cited by 196
General overview on the merits of multimodal neuroimaging data fusion
Uludaǧ, K., & Roebroeck, A. F. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.05.018 · Cited by 198
Targeted nanotechnology for cancer imaging
Toy, R., Bauer, L., Hoimes, C. J., Ghaghada, K. B., & Karathanasis, E. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.08.002 · Cited by 194
Rajiah, P. S., François, C. J., & Leiner, T. (2023) · Radiology · doi:10.1148/radiol.223008 · Cited by 189
Accelerated MR parameter mapping with low‐rank and sparsity constraints
Zhao, B., Lu, W., Hitchens, T. K., Lam, F., Ho, C., & Liang, Z. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25421 · Cited by 188
Fessler, J. A. (2020) · IEEE Signal Processing Magazine · doi:10.1109/msp.2019.2943645 · Cited by 188
Jones, D. K., Alexander, D. C., Bowtell, R. W., Cercignani, M., Dell’Acqua, F., McHugh, D. J., Miller, K. L., Palombo, M., Parker, G. J. M., Rudrapatna, U. S., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.05.047 · Cited by 187
Variability and Standardization of Quantitative Imaging
Hagiwara, A., Fujita, S., Ohno, Y., & Aoki, S. (2020) · Investigative Radiology · doi:10.1097/rli.0000000000000666 · Cited by 185
Sakadžić, S., Mandeville, E. T., Gagnon, L., Musacchia, J. J., Yaseen, M. A., Yücel, M. A., Lefebvre, J., Lesage, F., Dale, A. M., Eikermann‐Haerter, K., et al. (2014) · Nature Communications · doi:10.1038/ncomms6734 · Cited by 190
Multiparametric imaging with heterogeneous radiofrequency fields
Cloos, M. A., Knöll, F., Zhao, T., Block, K. T., Bruno, M. T., Wiggins, G. C., & Sodickson, D. K. (2016) · Nature Communications · doi:10.1038/ncomms12445 · Cited by 184
Improved magnetic resonance fingerprinting reconstruction with low‐rank and subspace modeling
Zhao, B., Setsompop, K., Elfar Adalsteinsson, A., Gagoski, B. A., Ye, H., Ma, D., Jiang, Y., Grant, P. E., Griswold, M. A., & Wald, L. L. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26701 · Cited by 179
Slice profile and B1 corrections in 2D magnetic resonance fingerprinting
Ma, D., Coppo, S., Chen, Y., McGivney, D., Jiang, Y., Pahwa, S. S., Gulani, V., & Griswold, M. A. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26580 · Cited by 172
Quantitative magnetic resonance imaging phantoms: A review and the need for a system phantom
Keenan, K. E., Ainslie, M., Barker, A. J., Boss, M. A., Cecil, K. M., Charles, C. H., Chenevert, T. L., Clarke, L., Evelhoch, J. L., Finn, J. P., et al. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26982 · Cited by 171
Better than real: Complex-valued neural nets for MRI fingerprinting
Virtue, P., Yu, S. X., & Lustig, M. S. (2017) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2017.8297024 · Cited by 171
Multiplexed imaging for diagnosis and therapy
Heinzmann, K., Carter, L. M., Lewis, J. S., & Aboagye, E. O. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0131-8 · Cited by 169
MRI-guided Radiation Therapy: An Emerging Paradigm in Adaptive Radiation Oncology
Otazo, R., Lambin, P., Pignol, J., Ladd, M. E., Schlemmer, H., Baumann, M. A., & Hricak, H. (2020) · Radiology · doi:10.1148/radiol.2020202747 · Cited by 170
Bringing MRI to low‐ and middle‐income countries: Directions, challenges and potential solutions
Murali, S., Ding, H., Adedeji, F., Qin, C., Obungoloch, J., Asllani, I., Anazodo, U., Ntusi, N., Mammen, R., Niendorf, T., et al. (2023) · NMR in Biomedicine · doi:10.1002/nbm.4992 · Cited by 183
MR Fingerprinting of Adult Brain Tumors: Initial Experience
Badve, C. A., Yu, A. C., Dastmalchian, S., Rogers, M., Ma, D., Jiang, Y., Margevicius, S. P., Pahwa, S. S., Lu, Z., SCHLUCHTER, M. D., et al. (2016) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5035 · Cited by 164
Development of a Combined MR Fingerprinting and Diffusion Examination for Prostate Cancer
Yu, A. C., Badve, C. A., Ponsky, L. E., Pahwa, S. S., Dastmalchian, S., Rogers, M., Jiang, Y., Margevicius, S. P., SCHLUCHTER, M. D., Tabayoyong, W., et al. (2017) · Radiology · doi:10.1148/radiol.2017161599 · Cited by 163
Fast 3D magnetic resonance fingerprinting for a whole‐brain coverage
Ma, D., Jiang, Y., Chen, Y., McGivney, D., Mehta, B., Gulani, V., & Griswold, M. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26886 · Cited by 158
Jiang, Y., Ma, D., Keenan, K. E., Stupic, K. F., Gulani, V., & Griswold, M. A. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26509 · Cited by 156
Zhao, B., Haldar, J. P., Liao, C., Ma, D., Jiang, Y., Griswold, M. A., Setsompop, K., & Wald, L. L. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2873704 · Cited by 151
MR fingerprinting with simultaneous B1 estimation
Buonincontri, G., & Sawiak, S. J. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26009 · Cited by 149
Brain imaging with portable low-field MRI
Kimberly, W. T., Sorby‐Adams, A., WEBB, A. G., Wu, E. X., Beekman, R. B., Bowry, R., Schiff, S. J., de Havenon, A., Shen, F. X., Sze, G. K., et al. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00086-w · Cited by 161
Accelerated High-Dimensional MR Imaging With Sparse Sampling Using Low-Rank Tensors
He, J., Liu, Q., Christodoulou, A., Ma, C., Lam, F., & Liang, Z. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2550204 · Cited by 146
Bustin, A., da Cruz, G. J. L., Jaubert, O., López, K., Botnar, R. M., & Prieto, C. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27694 · Cited by 144
Granberg, T., Uppman, M., Hashim, F., Cananau, C., Nordin, L. E., Shams, S., Berglund, J., Forslin, Y., Aspelin, P., Fredrikson, S., et al. (2016) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4665 · Cited by 141
Inferring brain tissue composition and microstructure via MR relaxometry
Does, M. D. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.087 · Cited by 137
Zhang, Q., Burrage, M. K., Lukaschuk, E., Shanmuganathan, M., Popescu, I. A., Nikolaidou, C., Mills, R., Werys, K., Hann, E., Barutcu, A., et al. (2021) · Circulation · doi:10.1161/circulationaha.121.054432 · Cited by 136
Image quality transfer and applications in diffusion MRI
Alexander, D. C., Zikic, D., Ghosh, A., Tanno, R., Wottschel, V., Zhang, J., Kaden, E., Dyrby, T. B., Sotiropoulos, S. N., Zhang, H. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.02.089 · Cited by 131
Echo planar time‐resolved imaging (EPTI)
Wang, F., Dong, Z., Reese, T. G., Bilgiç, B., Manhard, M. K., Chen, J. E., Polimeni, J. R., Wald, L. L., & Setsompop, K. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27673 · Cited by 130
Maximum Likelihood Reconstruction for Magnetic Resonance Fingerprinting
Zhao, B., Setsompop, K., Ye, H., Cauley, S., & Wald, L. L. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2531640 · Cited by 129
Fang, Z., Chen, Y., Liu, M., Xiang, L., Zhang, Q., Wang, Q., Lin, W., & Shen, D. G. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2899328 · Cited by 125
Joint MR-PET Reconstruction Using a Multi-Channel Image Regularizer
Knöll, F., Höller, M., Koesters, T., Otazo, R., Bredies, K., & Sodickson, D. K. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2564989 · Cited by 128
Cohen, O., Huang, S., McMahon, M. T., Rosen, M. S., & Farrar, C. T. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27221 · Cited by 128
The beginning of the end for conventional RECIST — novel therapies require novel imaging approaches
Gerwing, M., Herrmann, K., Helfen, A., Schliemann, C., Berdel, W. E., Eisenblätter, M., & Wildgruber, M. (2019) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-019-0169-5 · Cited by 130
Haubold, J., Demircioğlu, A., Gratz, M., Glas, M., Wrede, K. H., Sure, U., Antoch, G., Keyvani, K., Nittka, M., Kannengießer, S., et al. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04602-2 · Cited by 127
Multiplexed imaging in oncology
Andreou, C., Weissleder, R., & Kircher, M. F. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00891-5 · Cited by 132
Hernández-García, L., Lahiri, A., & Schollenberger, J. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.095 · Cited by 133
A Compressed Sensing Framework for Magnetic Resonance Fingerprinting
Davies, M. E., Puy, G., Vandergheynst, P., & Wiaux, Y. (2014) · SIAM Journal on Imaging Sciences · doi:10.1137/130947246 · Cited by 125
Liu, F., Feng, L., & Kijowski, R. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27707 · Cited by 125
Multicontrast MRI Reconstruction with Structure-Guided Total Variation
Ehrhardt, M. J., & Betcke, M. M. (2016) · SIAM Journal on Imaging Sciences · doi:10.1137/15m1047325 · Cited by 122
Deep learning for accelerated and robust MRI reconstruction
Heckel, R., Jacob, M., Chaudhari, A. S., Perlman, O., & Shimron, E. (2024) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-024-01173-8 · Cited by 162
Liao, C., Bilgiç, B., Manhard, M. K., Zhao, B., Cao, X., Zhong, J., Wald, L. L., & Setsompop, K. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.030 · Cited by 118
Reproducibility and Repeatability of MR Fingerprinting Relaxometry in the Human Brain
Koerzdoerfer, G., Kirsch, R., Liu, K., Pfeuffer, J., Hensel, B., Jiang, Y., Ma, D., Gratz, M., Bär, P., Bogner, W., et al. (2019) · Radiology · doi:10.1148/radiol.2019182360 · Cited by 118
Sparse Reconstruction Techniques in Magnetic Resonance Imaging
Yang, A. C., Kretzler, M. E., Sudarski, S., Gulani, V., & Seiberlich, N. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000274 · Cited by 117
Hagiwara, A., Hori, M., Cohen‐Adad, J., Nakazawa, M., Suzuki, Y., Kasahara, A., Horita, M., Haruyama, T., Andica, C., Maekawa, T., et al. (2018) · Investigative Radiology · doi:10.1097/rli.0000000000000510 · Cited by 120
4D image reconstruction for emission tomography
Reader, A. J., & Verhaeghe, J. A. J. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/22/r371 · Cited by 113
Magnetic resonance fingerprinting – An overview
Panda, A., Mehta, B. B., Coppo, S., Jiang, Y., Ma, D., Seiberlich, N., Griswold, M. A., & Gulani, V. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.11.001 · Cited by 114
Magnetic resonance fingerprinting: a technical review
Mehta, B. B., Coppo, S., McGivney, D., Hamilton, J., Chen, Y., Jiang, Y., Ma, D., Seiberlich, N., Gulani, V., & Griswold, M. A. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27403 · Cited by 114
Tanno, R., Worrall, D. E., Kaden, E., Ghosh, A., Grussu, F., Bizzi, A., Sotiropoulos, S. N., Criminisi, A., & Alexander, D. C. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117366 · Cited by 150
Fast group matching for MR fingerprinting reconstruction
Cauley, S., Setsompop, K., Ma, D., Jiang, Y., Ye, H., Elfar Adalsteinsson, A., Griswold, M. A., & Wald, L. L. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25439 · Cited by 112
Chen, Y., Liu, S., Wang, Y., Kang, Y., & Haacke, E. M. (2017) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2017.10.005 · Cited by 112
Accelerated T2 mapping combining parallel MRI and model‐based reconstruction: GRAPPATINI
Hilbert, T., Sumpf, T. J., Weiland, E., Frahm, J., Thiran, J., Meuli, R. A., Kober, T., & Krüger, G. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25972 · Cited by 111
Acceleration of MR parameter mapping using annihilating filter‐based low rank hankel matrix (ALOHA)
Lee, D., Jin, K. H., Kim, E. Y., Park, S., & Ye, J. C. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26081 · Cited by 110
Multicontrast MRI Reconstruction with Structure-Guided Total Variation
Ehrhardt, M. J., & Betcke, M. M. (2016) · Apollo (University of Cambridge) · doi:10.17863/cam.244 · Cited by 110
Rapid brain MRI acquisition techniques at ultra‐high fields
Setsompop, K., Feinberg, D. A., & Polimeni, J. R. (2016) · NMR in Biomedicine · doi:10.1002/nbm.3478 · Cited by 106
Ma, D., Jones, S. E., Deshmane, A., Sakaie, K., Pierre, E. Y., Larvie, M., McGivney, D., Blümcke, I., Krishnan, B., Lowe, M. J., et al. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26319 · Cited by 106
Integrated and efficient diffusion-relaxometry using ZEBRA
Hutter, J. M., Slator, P. J., Christiaens, D., Teixeira, R. P. A. G., Roberts, T. A., Jackson, L. H., Price, A. N., Malik, S., & Hajnal, J. V. (2018) · Scientific Reports · doi:10.1038/s41598-018-33463-2 · Cited by 98
Buonincontri, G., Biagi, L., Retico, A., Cecchi, P. C., Cosottini, M., Gallagher, F. A., Gómez, P. A., Graves, M. J., McLean, M. A., Riemer, F., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.047 · Cited by 102
Multiparametric estimation of brain hemodynamics with MR fingerprinting ASL
Su, P., Mao, D., Liu, P., Li, Y., Pinho, M. C., Welch, B. G., & Lu, H. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26587 · Cited by 100
Advances in arterial spin labelling MRI methods for measuring perfusion and collateral flow
van Osch, M. J. P., Teeuwisse, W. M., Chen, Z., Suzuki, Y., Helle, M., & Schmid, S. (2017) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x17713434 · Cited by 101
Speed in Clinical Magnetic Resonance
Runge, V. M., Richter, J. K., & Heverhagen, J. T. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000330 · Cited by 101
Multiscale reconstruction for MR fingerprinting
Pierre, E. Y., Ma, D., Chen, Y., Badve, C. A., & Griswold, M. A. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25776 · Cited by 99
T1‐/T2‐weighted ratio differs in demyelinated cortex in multiple sclerosis
Nakamura, K., Chen, J. T., Ontaneda, D., Fox, R. J., & Trapp, B. D. (2017) · Annals of Neurology · doi:10.1002/ana.25019 · Cited by 98
Metadata
- Authors
- Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A.
- Affiliations
- Case Western Reserve University (US)
- University Hospitals of Cleveland (US)
- Siemens Healthcare (United States) (US)
- Corresponding author
- Griswold, Mark A.
- ORCID
- Venue
- Nature
- Published
- 2013-03
- Volume
- 495
- Issue
- 7440
- Pages
- 187-192
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- PMC
- PMC3602925
- OpenAlex
- W2144288697
- Cited by
- 1,577
- References
- 53
- Citations by year
- 2026: 115 · 2025: 147 · 2024: 148 · 2023: 160 · 2022: 149 · 2021: 175 · 2020: 168 · 2019: 157 · 2018: 108 · 2017: 101 · 2016: 65 · 2015: 42 · 2014: 26 · 2013: 10
- FWCI
- 36.92
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- OhioLink ETD Center (Ohio Library and Information Network) (submittedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Funders
- Agence Nationale de la Recherche (ANR-20-CE19-0030, ANR-11-INBS-0006, ANR-21-CE17-0028)
- National Institutes of Health (KL2TR000440)
- National Heart, Lung, and Blood Institute (R01HL094557)
- National Center for Advancing Translational Sciences
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Keywords
- magnetic resonance fingerprinting, quantitative MRI, pattern recognition, tissue characterization, disease detection, non-invasive measurement, nuclear magnetic resonance
- MeSH terms
- Algorithms, Diagnostic Tests, Routine, Humans, Motion, Magnetic Resonance Spectroscopy, Pattern Recognition, Automated, Research Design, Sensitivity and Specificity, Reproducibility of Results, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review