The present and future role of microfluidics in biomedical research
The DOI matches its Crossref record; 103 of the 106 references it cites were found in a registry or an index.
Abstract
Microfluidics, a technology characterized by the engineered manipulation of fluids at the submillimetre scale, has shown considerable promise for improving diagnostics and biology research. Certain properties of microfluidic technologies, such as rapid sample processing and the precise control of fluids in an assay, have made them attractive candidates to replace traditional experimental approaches. Here we analyse the progress made by lab-on-a-chip microtechnologies in recent years, and discuss the clinical and research areas in which they have made the greatest impact. We also suggest directions that biologists, engineers and clinicians can take to help this technology live up to its potential.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Yet, challenges remain before microfluidic assays can be routinely used in the clinic [82, 83] (Outstanding Question Box) [84].”
From Microfluidics: A New Tool for Modeling Cancer–Immune Interactions (2016) · cites this paper as [84]
In the citing paper
“Sackmann et al. estimated that 85% of microfluidic related publications are published in engineering, as opposed to clinical or biological journals, mostly as proof-of-principle studies[84].”
From Microfluidics: A New Tool for Modeling Cancer–Immune Interactions (2016) · cites this paper as [84]
In the citing paper
“Other challenges associated with microfluidic systems for translational immunology are manufacturability and scalability[66], limited by, for example, the predominant use of PDMS for making devices[84].”
From Microfluidics: A New Tool for Modeling Cancer–Immune Interactions (2016) · cites this paper as [84]
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Comparison of PubMed, Scopus, Web of Science, and Google Scholar: strengths and weaknesses
Falagas, M. E., Pitsouni, E. I., Malietzis, G. A., & Pappas, G. (2008) · The FASEB Journal · doi:10.1096/fj.07-9492lsf · Cited by 5,039
The price of innovation: new estimates of drug development costs
DiMasi, J. A., Hansen, R. W., & Grabowski, H. G. (2003) · Journal of Health Economics · doi:10.1016/s0167-6296(02)00126-1 · Cited by 4,265
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
How to improve R&D productivity: the pharmaceutical industry's grand challenge
Paul, S. M., Mytelka, D. S., Dunwiddie, C. T., Persinger, C. C., Munos, B. H., Lindborg, S. R., & Schacht, A. L. (2010) · Nature Reviews Drug Discovery · doi:10.1038/nrd3078 · Cited by 3,566
Miniaturized total chemical analysis systems: A novel concept for chemical sensing
Manz, A., Graber, N., & Widmer, H. M. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80209-i · Cited by 3,122
THE CHEMOTACTIC EFFECT OF MIXTURES OF ANTIBODY AND ANTIGEN ON POLYMORPHONUCLEAR LEUCOCYTES
Boyden, S. (1962) · The Journal of Experimental Medicine · doi:10.1084/jem.115.3.453 · Cited by 2,733
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Research works printed but not linked: 1
- Chin, C. D. et al. Microfluidics-based diagnostics of infectious diseases in the developing world. Nature Med. 17, 1015–1019 (2011) · DOI · Paper page
Cited by
Items 701–800 of 1,003
Yu, M., Chen, X., Qu, H., Ma, L., Xu, L., Lv, W., Wang, H., Ismagilov, R. F., Li, M., & Shen, F. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01270 · Cited by 48
Isolation of circulating tumour cells by physical means in a microfluidic device: a review
Patil, P., Madhuprasad, M., Kumeria, T., Losic, D., & Kurkuri, M. (2015) · RSC Advances · doi:10.1039/c5ra16489c · Cited by 47
Luo, T. L., Vanek, M. E., González‐Cabezas, C., Marrs, C. F., Foxman, B., & Rickard, A. H. (2021) · Journal of Applied Microbiology · doi:10.1111/jam.15200 · Cited by 47
“Microfluidics involves the engineered delivery of fluids on the submillilitre levels through microchannels (Sackmann et al., 2014).”
BackgroundRealizing the multifunctional metamaterial for fluid flow in a porous medium
Chen, M., Shen, X., Chen, Z., Lo, J. H. Y., Liu, Y., Xu, X., Wu, Y., & Xu, L. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2207630119 · Cited by 47
Zhang, Y., Lei, F., Qian, W., Zhang, C., Wang, Q., Liu, C., Ji, H., Liu, Z., & Wang, F. (2024) · Journal of Controlled Release · doi:10.1016/j.jconrel.2024.07.073 · Cited by 48
Shi, X., Pu, H., Shi, L. L., He, T., & Chen, J. (2025) · Nanoscale · doi:10.1039/d4nr04441j · Cited by 50
Li, Y., Xuan, J., Song, Y., Wang, P., & Qin, L. (2015) · Lab on a Chip · doi:10.1039/c5lc00529a · Cited by 47
Cell migration in microengineered tumor environments
Um, E., Oh, J. M., Granick, S., & Cho, Y. (2017) · Lab on a Chip · doi:10.1039/c7lc00555e · Cited by 47
Advances in paper-analytical methods for pharmaceutical analysis
Sharma, N., Barstis, T., & Giri, B. (2017) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2017.09.031 · Cited by 47
Montessori, A., Lauricella, M., Rocca, M. L., Succi, S., Stolovicki, E., Ziblat, R., & Weitz, D. A. (2018) · Computers & Fluids · doi:10.1016/j.compfluid.2018.02.029 · Cited by 47
“Nowadays, many publications show that the microfluidics has surged well beyond the proofof-concept paradigm, proving the viability of the new approach through substantial contributions to chemistry, biology, medicine, 3d-printing, to name but a few [8, 9, 10, 11, 12].”
BackgroundXu, B., Shi, Y., Lao, Z., Ni, J., Li, G., Hu, Y., Li, J., Chu, J., Wu, D., & Sugioka, K. (2017) · Lab on a Chip · doi:10.1039/c7lc01080j · Cited by 47
Chen, A., Fu, G., Xu, Z., Sun, Y., Chen, X., Cheng, K. S., Neoh, K. H., Tang, Z., Chen, S., Liu, M., et al. (2018) · Cancer Research · doi:10.1158/0008-5472.can-17-2615 · Cited by 47
“This is especially important for minimizing cell loss and to allow for a more precise handling (32) during a sampling process of urine samples with sparse cell materials.”
BackgroundFuture of microfluidics in research and in the market
Bohr, A., Colombo, S., & Jensen, H. M. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812659-2.00016-8 · Cited by 47
Taghizadeh-Behbahani, M., Hemmateenejad, B., Shamsipur, M., & Tavassoli, A. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.06.050 · Cited by 47
Agostini, M., Greco, G., & Cecchini, M. G. (2019) · APL Materials · doi:10.1063/1.5070136 · Cited by 47
Molinero‐Fernández, Á., Moreno‐Guzmán, M., López, M. Á., & Escarpa, A. (2020) · Biosensors · doi:10.3390/bios10060066 · Cited by 48
Ayensa-Jiménez, J., Pérez-Aliacar, M., Ranđelović, T., Oliván, S., Fernández, L. J., Sanz‐Herrera, J. A., Ochoa, I., Doweidar, M. H., & Doblaré, M. (2020) · Scientific Reports · doi:10.1038/s41598-020-78215-3 · Cited by 49
Shape‐Changing Particles: From Materials Design and Mechanisms to Implementation
Tanjeem, N., Minnis, M. B., Hayward, R. C., & Shields, C. W. (2021) · Advanced Materials · doi:10.1002/adma.202105758 · Cited by 48
Hsieh, K., Melendez, J. H., Gaydos, C. A., & Wang, T. (2022) · Lab on a Chip · doi:10.1039/d1lc00665g · Cited by 47
Microfluidic Brain‐on‐a‐Chip: From Key Technology to System Integration and Application
Wang, Z., Zhang, Y., Li, Z., Wang, H., Li, N., & Deng, Y. (2023) · Small · doi:10.1002/smll.202304427 · Cited by 47
Ravi, K., Manoharan, T. J. M., Wang, K.-C., Pockaj, B. A., & Nikkhah, M. (2023) · Biomaterials · doi:10.1016/j.biomaterials.2023.122428 · Cited by 47
Heart-on-a-chip systems: disease modeling and drug screening applications
Butler, D., & Reyes, D. R. (2024) · Lab on a Chip · doi:10.1039/d3lc00829k · Cited by 47
Liu, H., Yu, X., Cai, B., You, S., He, Z., Huang, Q., Rao, L., Li, S., Liu, C., Sun, W., et al. (2015) · Applied Physics Letters · doi:10.1063/1.4914015 · Cited by 46
Patent protection and licensing in microfluidics
Yetisen, A. K., & Volpatti, L. R. (2014) · Lab on a Chip · doi:10.1039/c4lc00399c · Cited by 40
Controlled Drug Release and Chemotherapy Response in a Novel Acoustofluidic 3D Tumor Platform
Zervantonakis, I. K., & Arvanitis, C. D. (2016) · Small · doi:10.1002/smll.201503342 · Cited by 44
Deng, F., Zhao, L., Pei, X., Luo, X., & Luo, S. (2016) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2016.12.028 · Cited by 46
Application of Microfluidics in Experimental Ecology: The Importance of Being Spatial
Nagy, K., Ábrahám, Á., Keymer, J. E., & Galajda, P. (2018) · Frontiers in Microbiology · doi:10.3389/fmicb.2018.00496 · Cited by 47
“…proved to be useful in a vast spectrum of medical, biological and chemical research (Liu and Zhu, 2005; Melin and Quake, 2007; Weibel et al., 2007; Hol and Dekker, 2014; Sackmann et al., 2014; CastilloLeón, 2015; Samiei et al., 2016; Wu and Dekker, 2016; XiaoYing, 2016; Shang et al., 2017).”
BackgroundInjection-Molded Microfluidic Device for SERS Sensing Using Embedded Au-Capped Polymer Nanocones
Viehrig, M., Thilsted, A. H., Matteucci, M., Wu, K., Catak, D., Schmidt, M., Zór, K., & Boisen, A. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b13424 · Cited by 46
Intracellular Labeling with Extrinsic Probes: Delivery Strategies and Applications
Liu, J., Fraire, J. C., Smedt, S. C. D., Xiong, R., & Braeckmans, K. (2020) · Small · doi:10.1002/smll.202000146 · Cited by 47
MEMS Biosensors and COVID-19: Missed Opportunity
Leïchlé, T., Nicu, L., & Alava, T. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01463 · Cited by 46
Bionic microchannels for step lifting transpiration
Wang, Z., Yin, Q., Zhan, Z., Li, W., Xie, M., Duan, H., Cheng, P., Zhang, C., Chen, Y., & Dong, Z. (2023) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/acbcff · Cited by 46
Sackmann, E. K., Majlof, L., Hahn-Windgassen, A., Eaton, B., Bandzava, T., Daulton, J., Vandenbroucke, A., Mock, M., Stearns, R. G., Hinkson, S., et al. (2015) · SLAS TECHNOLOGY · doi:10.1177/2211068215602191 · Cited by 46
“Furthermore, the relative importance of forces acting on the fluid, such as surface tension and gravity, change as the fluid volume is depleted within the well.(11,12) Therefore, successfully diagnosing the energy required to acoustically eject a droplet from the fluid surface requires frequent auditing of the fluids’…”
BackgroundSelf-citationA Role for 3D Printing in Kidney-on-a-Chip Platforms
Sochol, R. D., Gupta, N. R., & Bonventre, J. V. (2016) · Current Transplantation Reports · doi:10.1007/s40472-016-0085-x · Cited by 46
Li, M., Liu, L., Xiao, X., Xi, N., & Wang, Y. (2016) · Journal of Biological Physics · doi:10.1007/s10867-016-9423-6 · Cited by 46
“cells from the clinical patient (such as via micro-fluidics [52, 53]) and then examine”
BackgroundRahimnejad, M., Rabiee, N., Ahmadi, S., Jahangiri, S., Sajadi, S. M., Akhavan, O., Saeb, M. R., Kwon, W., Kim, M., & Hahn, S. K. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.1c00932 · Cited by 45
4D Printing of Butterfly Scale–Inspired Structures for Wide‐Angle Directional Liquid Transport
Liu, X., Li, B., Gu, Z., & Zhou, K. (2023) · Small · doi:10.1002/smll.202207640 · Cited by 45
CRISPR-based one-pot detection: A game-changer in nucleic acid analysis
Li, X., Liu, J., Wang, R., Fu, H., Kim, M., Li, X., Peng, W., Man, S., Gao, Z., & Ma, L. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117786 · Cited by 46
Femtosecond laser direct generation of 3D-microfluidic channels inside bulk PMMA
Roth, G., Esen, C., & Hellmann, R. (2017) · Optics Express · doi:10.1364/oe.25.018442 · Cited by 45
Applications of Microfluidics in Quantitative Biology
Bai, Y., Gao, M., Wen, L., He, C., Chen, Y., Liu, C., Fu, X., & Huang, S. (2017) · Biotechnology Journal · doi:10.1002/biot.201700170 · Cited by 45
Razor-printed sticker microdevices for cell-based applications
Stallcop, L. E., Álvarez-García, Y. R., Reyes-Ramos, A. M., Ramos-Cruz, K. P., Morgan, M. M., Shi, Y., Li, L., Beebe, D. J., Domenech, M., & Warrick, J. W. (2018) · Lab on a Chip · doi:10.1039/c7lc00724h · Cited by 45
Self-citationMulti-criteria optimization of curved and baffle-embedded micromixers for bio-applications
Rasouli, M., Mehrizi, A. A., Goharimanesh, M., Lashkaripour, A., & Bazaz, S. R. (2018) · Chemical Engineering and Processing · doi:10.1016/j.cep.2018.08.021 · Cited by 42
Comes, M. C., Casti, P., Mencattini, A., Giuseppe, D. D., Mermet‐Meillon, F., Ninno, A. D., Parrini, M. C., Businaro, L., Natale, C. D., & Martinelli, E. (2019) · Scientific Reports · doi:10.1038/s41598-019-42475-5 · Cited by 45
Submicron Particle and Cell Concentration in a Closed Chamber Surface Acoustic Wave Microcentrifuge
Akther, A., Marqus, S., Rezk, A. R., & Yeo, L. Y. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c01757 · Cited by 45
Advances in numerical approaches for microfluidic cell analysis platforms
Sheidaei, Z., Akbarzadeh, P., & Kashaninejad, N. (2020) · Journal of Science Advanced Materials and Devices · doi:10.1016/j.jsamd.2020.07.008 · Cited by 45
Yasui, T., Paisrisarn, P., Yanagida, T., Konakade, Y., Nakamura, Y., Nagashima, K., Musa, M., Thiodorus, I. A., Takahashi, H., Naganawa, T., et al. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113589 · Cited by 45
Lin, X., Wu, H., Zeng, S., Peng, T., Zhang, P., Wan, X., Lang, Y., Zhang, B., Jia, Y., Shen, R., et al. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115283 · Cited by 45
Mechanically Defined Microgels by Droplet Microfluidics
Heida, T., Neubauer, J. W., Seuß, M., Hauck, N., Thiele, J., & Fery, A. (2016) · Macromolecular Chemistry and Physics · doi:10.1002/macp.201600418 · Cited by 45
Hydrogel Microspheres Empowering Organ‐on‐a‐Chip Systems: Innovations and Applications
Liu, J., Du, C., Chen, J., Tang, B., Liu, S., Tan, J., Luo, X., Zhan, J., Liu, J., Chen, Z., et al. (2025) · Small · doi:10.1002/smll.202504563 · Cited by 44
Carugo, D., Lee, J. Y., Pora, A., Browning, R. J., Capretto, L., Nastruzzi, C., & Stride, E. (2016) · Biomedical Microdevices · doi:10.1007/s10544-015-0027-x · Cited by 44
“Microbubbles”
Duchesne, L., & Lacombe, K. (2017) · Journal of Viral Hepatitis · doi:10.1111/jvh.12827 · Cited by 44
“highlighted that LOC studies are published primarily in engineering journals and therefore do not reach clinicians or biologists, although they are the most likely potential end-users (54).”
BackgroundWang, S., Majumder, S., Emery, N. J., & Liu, A. P. (2018) · Synthetic Biology · doi:10.1093/synbio/ysy005 · Cited by 44
Xu, Z. C., Fang, P., Xu, B., Lu, Y., Xiong, J., Gao, F., Wang, X., Fan, J., & Shi, P. (2018) · Nature Communications · doi:10.1038/s41467-018-07186-x · Cited by 44
Nebulization using ZnO/Si surface acoustic wave devices with focused interdigitated transducers
Zhou, J. W., Tao, X., Luo, J., Li, Y., Jin, H., Dong, S., Luo, J., Duan, H., & Fu, Y. (2019) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2019.03.078 · Cited by 44
Virumbrales-Muñoz, M., Ayuso, J. M., Lacueva, A., Randelovic, T., Livingston, M. K., Beebe, D. J., Oliván, S., Pereboom, D., Doblare, M., Fernández, L., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-42529-8 · Cited by 41
Self-citationYan, L., Zhang, H., Yang, R., Tazrin, F., Zhu, C., Kaddoura, M., Blondeel, E. J. M., & Cui, B. (2019) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2019.04.008 · Cited by 44
Asymmetrical Split-and-Recombine Micromixer with Baffles
Raza, W., & Kim, K. (2019) · Micromachines · doi:10.3390/mi10120844 · Cited by 44
FertDish: microfluidic sperm selection-in-a-dish for intracytoplasmic sperm injection
Xiao, S., Riordon, J., Simchi, M., Lagunov, A., Hannam, T., Jarvi, K. A., Nosrati, R., & Sinton, D. A. (2021) · Lab on a Chip · doi:10.1039/d0lc00874e · Cited by 44
Srikanth, S., Dudala, S., Jayapiriya, U. S., Mohan, J. M., Raut, S. Y., Dubey, S. K., Ishii, I., Javed, A., & Goel, S. (2021) · Scientific Reports · doi:10.1038/s41598-021-88068-z · Cited by 44
“(1) (where P is power, V is applied voltage and R is resistance), a pattern with lowest resistance can transduce high thermal energy for a given electrical energy.”
BackgroundUltrafast laser manufacturing of nanofluidic systems
Sima, F., & Sugioka, K. (2021) · Nanophotonics · doi:10.1515/nanoph-2021-0159 · Cited by 44
Song, X.-C., Yu, Y., Yang, G.-Y., Jiang, A.-L., Ruan, Y.-J., & Fan, S.-H. (2022) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2022.112560 · Cited by 44
Wang, H., & Mercier, P. P. (2017) · Scientific Reports · doi:10.1038/s41598-017-04705-6 · Cited by 43
“μ φ = − φ − I C W L n e ( 1) (2) sub ox T V V”
BackgroundRecent Advances in Solid-Phase Extraction as a Platform for Sample Preparation in Biomarker Assay
Hamidi, S. (2022) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2021.1947771 · Cited by 43
“Microfluidic arrangements prompt a wide range of applications such as sample assay, medical diagnostics, cell biology, and single-cell detecting methods.([89,90]) Integration SPE in microfluidic devices leads to the design of novel method-”
Xu, Y., Wu, L., Tang, Y., Cai, F., Xi, K., Tang, J., Xu, Z., Gu, Y., Cui, W., & Chen, L. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121685 · Cited by 43
Liu, W., & Lin, J. (2016) · ACS Sensors · doi:10.1021/acssensors.5b00221 · Cited by 43
Konstantinou, D., Shirazi, A., Sadri, A., & Young, E. W. K. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.04.147 · Cited by 43
Apparent slip of shear thinning fluid in a microchannel with a superhydrophobic wall
Патлажан, С. А., & Vagner, S. (2017) · Physical review. E · doi:10.1103/physreve.96.013104 · Cited by 43
Microfluidics for Combating Antimicrobial Resistance
Liu, Z., Banaei, N., & Ren, K. (2017) · Trends in biotechnology · doi:10.1016/j.tibtech.2017.07.008 · Cited by 43
“Its general background was well-summarized by Whitesides [11], while others have reviewed its application and potential in biology, chemistry, and medicine [12,13].”
BackgroundLiu, Y., Schulze‐Makuch, D., Vera, J.-P. P. D., Cockell, C. S., Leya, T., Baqué, M., & Walther-Antonio, M. R. S. (2018) · Micromachines · doi:10.3390/mi9080367 · Cited by 43
Lab-on-a-chip technology and microfluidics
Francesko, A., Cardoso, V. F., & Lanceros-Méndez, S. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812659-2.00001-6 · Cited by 43
Wei, Y., Zhu, Y., & Fang, Q. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04564 · Cited by 43
He, L., Shen, Z., Cao, Y., Li, T., Wu, D., Dong, Y., & Gan, N. (2019) · The Analyst · doi:10.1039/c9an00106a · Cited by 43
Full-SAW Microfluidics-Based Lab-on-a-Chip for Biosensing
Agostini, M., Greco, G., & Cecchini, M. G. (2019) · IEEE Access · doi:10.1109/access.2019.2919000 · Cited by 43
“These operations include centrifugation, reagent mixing, heating, particle separation, cell counting, analyte detection, amongst many others, as described in Sackmann’s review [4] and references within.”
MethodDhayakaran, R., Neethirajan, S. R., & Weng, X. (2016) · Biochemistry and Biophysics Reports · doi:10.1016/j.bbrep.2016.04.001 · Cited by 43
“Microfluidics technology is a fast-growing field that overcomes the disadvantages of these conventional assays by being able to provide high throughput screening, real-time examination of samples, usage of very low amounts of reagents, rapid screening, parallel testing of multiple drugs, all while saving space [9,21,3…”
BackgroundTaylor, J. J., Jaedicke, K. M., van de Merwe, R. C., Bissett, S. M., Landsdowne, N., Whall, K. M., Pickering, K., Thornton, V., Lawson, V., Yatsuda, H., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-47513-w · Cited by 43
Samandari, M., Rafiee, L., Alipanah, F., Sanati‐Nezhad, A., & Javanmard, S. H. (2021) · Scientific Reports · doi:10.1038/s41598-021-89635-0 · Cited by 54
Adampourezare, M., Dehghan, G., Hasanzadeh, M., & Feizi, M. H. (2021) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2021.111845 · Cited by 43
Recent Advances in Drug Delivery System Fabricated by Microfluidics for Disease Therapy
Jia, F., Gao, Y., & Wang, H. (2022) · Bioengineering · doi:10.3390/bioengineering9110625 · Cited by 43
“The interface factors such as diffusion, surface tension and viscosity become the main factors affecting the fluid behavior [3].”
BackgroundManufacturing microstructured tool inserts for the production of polymeric microfluidic devices
Zhang, N., Srivastava, A., Kirwan, B., Byrne, R., Fang, F., Browne, D. J., & Gilchrist, M. D. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/9/095005 · Cited by 43
“However, the adoption of microfluidic technology into mainstream biology research and commercial markets has not matched the initial enthusiasm for lab on a chip technology [3, 4].”
BackgroundWang, H., Liu, X., Nan, K., Chen, B., He, M., & Hu, B. (2017) · Journal of Analytical Atomic Spectrometry · doi:10.1039/c6ja00077k · Cited by 45
Advances in controlled-release fertilizer encapsulated by organic-inorganic composite membranes
Wang, X., Yang, Y., Zhong, S., Meng, Q., Li, Y., Wang, J., Gao, Y., & Cui, X. (2023) · Particuology · doi:10.1016/j.partic.2023.06.019 · Cited by 42
Ultrasonic welding for fast bonding of self-aligned structures in lab-on-a-chip systems
Kistrup, K., Poulsen, C. E., Hansen, M. F., & Wolff, A. (2015) · Lab on a Chip · doi:10.1039/c5lc00174a · Cited by 42
Yücel, M., Beaton, A. D., Dengler, M., Mowlem, M. C., Sohl, F., & Sommer, S. (2015) · PLoS ONE · doi:10.1371/journal.pone.0132785 · Cited by 42
“Having been mostly developed for medical and pharmaceutical research [22], LOC technology is now being transferred to aquatic environmental research as well [23–27].”
BackgroundRecent Progress of Microfluidics in Translational Applications
Liu, Z., Han, X., & Qin, L. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600009 · Cited by 42
Solvent Bonding for Fabrication of PMMA and COP Microfluidic Devices
Wan, A. M. D., Moore, T. A., & Young, E. W. K. (2017) · Journal of Visualized Experiments · doi:10.3791/55175 · Cited by 42
Bioinspired Universal Flexible Elastomer‐Based Microchannels
Wu, F., Chen, S., Chen, B., Wang, M., Min, L., Alvarenga, J., Ju, J., Khademhosseini, A., Yao, Y., Zhang, Y. S., et al. (2018) · Small · doi:10.1002/smll.201702170 · Cited by 42
A Multiplexed Serologic Test for Diagnosis of Lyme Disease for Point-of-Care Use
Arumugam, S., Nayak, S., Williams, T., Maria, F. S. D. S., Guedes, M. S., Chaves, R. C., Linder, V., Marques, A. R., Horn, E. J., Wong, S. J., et al. (2019) · Journal of Clinical Microbiology · doi:10.1128/jcm.01142-19 · Cited by 42
Computer-Aided Design of Microfluidic Circuits
Tsur, E. E. (2020) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-082219-033358 · Cited by 42
Patil, A. B., Meng, Z., Wu, R., Ma, L., Xu, Z., Shi, C., Qiu, W., Liu, Q., Zhang, Y., Lin, Y., et al. (2020) · Nano-Micro Letters · doi:10.1007/s40820-020-00459-5 · Cited by 44
Rahmanian, M., Seyfoori, A., Ghasemi, M., Shamsi, M., Kolahchi, A. R., Modarres, H. P., Sanati‐Nezhad, A., & Majidzadeh‐A, K. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2021.04.024 · Cited by 42
Predicting cell behaviour parameters from glioblastoma on a chip images. A deep learning approach
Pérez-Aliacar, M., Doweidar, M. H., Doblaré, M., & Ayensa-Jiménez, J. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104547 · Cited by 43
Going with the Flow: Modeling the Tumor Microenvironment Using Microfluidic Technology
Xie, H., Appelt, J. W., & Jenkins, R. W. (2021) · Cancers · doi:10.3390/cancers13236052 · Cited by 42
A review of the gas hydrate phase transition with a microfluidic approach
Liu, Q., Liu, Y., Xu, J., Teng, Y., Ling, Z., Zhang, Y., Jiang, L., & Song, Y. (2022) · Energy Reviews · doi:10.1016/j.enrev.2022.100011 · Cited by 42
Precision nutrition — review of methods for point-of-care assessment of nutritional status
Srinivasan, B., Lee, S., Erickson, D., & Mehta, S. (2016) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2016.12.001 · Cited by 42
Hartman, S. V., Božič, B., & Derganc, J. (2018) · New Biotechnology · doi:10.1016/j.nbt.2018.02.015 · Cited by 42
In vitro micro-physiological models for translational immunology
Ramadan, Q., & Gijs, M. A. M. (2015) · Lab on a Chip · doi:10.1039/c4lc01271b · Cited by 41
Building bio-assays with magnetic particles on a digital microfluidic platform
Kokalj, T., Ruiz, E., & Lammertyn, J. (2015) · New Biotechnology · doi:10.1016/j.nbt.2015.03.007 · Cited by 41
A Microfluidic Platform for Evaluating Neutrophil Chemotaxis Induced by Sputum from COPD Patients
Wu, J., Hillier, C. T., Komenda, P. V. J., de Faria, R. L., Levin, D. B., Zhang, M., & Lin, F. (2015) · PLoS ONE · doi:10.1371/journal.pone.0126523 · Cited by 41
“The main limitation of spirometry is that it requires patient cooperation, which can be difficult for patients with severe conditions, or if the patients cannot comprehend and follow the procedures [16].”
BackgroundLei, K. F., Tseng, H.-P., Lee, C.-Y., & Tsang, N.-M. (2016) · Scientific Reports · doi:10.1038/srep25557 · Cited by 38
“In the past decades, development of microfluidic technology becomes mature and a lot of biomedical applications have been demonstrated on microfluidic systems 8–10 .”
Magnetic Shape Memory Micropump for Submicroliter Intracranial Drug Delivery in Rats
Barker, S., Rhoads, E., Lindquist, P. G., Vreugdenhil, M., & Müllner, P. (2016) · Journal of Medical Devices · doi:10.1115/1.4034576 · Cited by 41
Droplet Microarray Based on Superhydrophobic-Superhydrophilic Patterns for Single Cell Analysis
Jogia, G., Tronser, T., Popova, A. A., & Levkin, P. A. (2016) · Microarrays · doi:10.3390/microarrays5040028 · Cited by 41
Metadata
- Authors
- Sackmann, E. K., Fulton, A. L., & Beebe, D. J.
- Affiliations
- University of Wisconsin–Madison (US)
- Corresponding author
- Beebe, David J.
- Venue
- Nature
- Published
- 2014-03
- Volume
- 507
- Issue
- 7491
- Pages
- 181-189
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2001607419
- Cited by
- 2,995
- References
- 106
- Citations by year
- 2026: 215 · 2025: 231 · 2024: 224 · 2023: 226 · 2022: 231 · 2021: 248 · 2020: 248 · 2019: 316 · 2018: 273 · 2017: 291 · 2016: 230 · 2015: 185 · 2014: 74
- FWCI
- 22.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Keywords
- microfluidics, lab-on-a-chip, point-of-care testing, DNA microarrays, inkjet printing, clinical diagnostics, biomedical research applications
- MeSH terms
- Animals, Body Fluids, Chemotaxis, Diagnostic Tests, Routine, Humans, Biomedical Research, Microfluidics, Microfluidic Analytical Techniques, Cell Migration Assays, Drug Discovery
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.