The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Direct high-precision measurement of the magnetic moment of the proton
Open accessAbstract
One of the fundamental properties of the proton is its magnetic moment, µp. So far µp has been measured only indirectly, by analysing the spectrum of an atomic hydrogen maser in a magnetic field. Here we report the direct high-precision measurement of the magnetic moment of a single proton using the double Penning-trap technique. We drive proton-spin quantum jumps by a magnetic radio-frequency field in a Penning trap with a homogeneous magnetic field. The induced spin transitions are detected in a second trap with a strong superimposed magnetic inhomogeneity. This enables the measurement of the spin-flip probability as a function of the drive frequency. In each measurement the proton’s cyclotron frequency is used to determine the magnetic field of the trap. From the normalized resonance curve, we extract the particle’s magnetic moment in terms of the nuclear magneton: μp = 2.792847350(9)μN. This measurement outperforms previous Penning-trap measurements in terms of precision by a factor of about 760. It improves the precision of the forty-year-old indirect measurement, in which significant theoretical bound state corrections were required to obtain µp, by a factor of 3. By application of this method to the antiproton magnetic moment, the fractional precision of the recently reported value can be improved by a factor of at least 1,000. Combined with the present result, this will provide a stringent test of matter/antimatter symmetry with baryons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beringer, J., Arguin, J. F., Barnett, R. M., Copic, K., Dahl, O., Groom, D. E., Lin, C. J., Lys, J., Murayama, H., Wohl, C. G., et al. (2012) · Physical Review D · doi:10.1103/physrevd.86.010001 · Cited by 5,978
Particle Data Group, Workman, R. L., Burkert, V. D., Crede, V, Klempt, E., Thoma, U., Tiator, L., Agashe, K., Aielli, G., Allanach, B. C., et al. (2022) · Progress of Theoretical and Experimental Physics · doi:10.1093/ptep/ptac097 · Cited by 5,964
Data analysis: a Bayesian tutorial
(1997) · Choice Reviews Online · doi:10.5860/choice.34-5742 · Cited by 1,630
Pohl, R., Antognini, A., Nez, F., Amaro, F. D., Biraben, F., Cardoso, J. M. R., Covita, D. S., Dax, A., Dhawan, S., Fernandes, L. M. P., et al. (2010) · Nature · doi:10.1038/nature09250 · Cited by 1,374
Geonium theory: Physics of a single electron or ion in a Penning trap
Brown, L. S., & Gabrielse, G. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.233 · Cited by 1,367 · cited 4×
“In addition to these two leading-order shifts, relativistic frequency shifts and imagecharge shifts contribute [15].”
BackgroundMethodInfluentialNew measurement of the electron magnetic moment and the fine structure constant
Hanneke, D., Fogwell, S., & Gabrielse, G. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.120801 · Cited by 1,138 · cited 1×
“positron [13] and further improved in [14], where fractional precisions at the level of 3.”
BackgroundNew high-precision comparison of electron and positron g factors
Van Dyck, R. S., Schwinberg, P. B., & Dehmelt, H. G. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.26 · Cited by 659
Data Analysis: A Bayesian Tutorial
Fox, E. P. (1998) · Technometrics · doi:10.1080/00401706.1998.10485200 · Cited by 647
Principles of the stored ion calorimeter
Wineland, D. J., & Dehmelt, H. G. (1975) · Journal of Applied Physics · doi:10.1063/1.321602 · Cited by 328 · cited 1×
“Once the axial motion is cooled to thermal equilibrium, the particle shorts the thermal noise of the detector and appears as a dip in the fast Fourier transform (FFT) of the detector signal [21].”
BackgroundHigh-precision measurement of the atomic mass of the electron
Sturm, S., Köhler, F., Zatorski, J., Wagner, A., Harman, Z., Werth, G., Quint, W., Keitel, C. H., & Blaum, K. (2014) · Nature · doi:10.1038/nature13026 · Cited by 326 · cited 1×
“14 parts in a billion (ppb) [10], and the proton-to-electron mass ratio was determined with a relative accuracy of 94 parts in 10 12 [11].”
MethodSelf-citation
Research works printed but not linked: 1
- Dehmelt, H. G. & Ekström, P. Proposed g-2 experiment on single stored electron or positron. Bull. Am. Phys. Soc. 18, 727–731 (1973)
Cited by
Search for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560
CODATA recommended values of the fundamental physical constants: 2014
Mohr, P. J., Newell, D. B., & Taylor, B. N. (2016) · Reviews of Modern Physics · doi:10.1103/revmodphys.88.035009 · Cited by 920
CODATA recommended values of the fundamental physical constants: 2018
Tiesinga, E., Mohr, P. J., Newell, D. B., & Taylor, B. N. (2021) · Reviews of Modern Physics · doi:10.1103/revmodphys.93.025010 · Cited by 908
Muon (g-2) Technical Design Report
Grange, J., & High Energy Physics (HEP) USDOE Office of Science (SC) (2015) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1251172 · Cited by 558
CODATA Recommended Values of the Fundamental Physical Constants: 2018
Tiesinga, E., Mohr, P. J., Newell, D. B., & Taylor, B. N. (2021) · Journal of Physical and Chemical Reference Data · doi:10.1063/5.0064853 · Cited by 299
Metadata
- Authors
- Mooser, A., Ulmer, S., Blaum, K., Franke, K., Kracke, H., Leiteritz, C., Quint, W., Rodegheri, C. C., Smorra, C., & Walz, J.
- Affiliations
- Johannes Gutenberg University Mainz (DE)
- RIKEN (JP)
- Max Planck Institute for Nuclear Physics (DE)
- GSI Helmholtz Centre for Heavy Ion Research (DE)
- Corresponding author
- Mooser, A.
- Venue
- Nature
- Published
- 2014-05-28
- Volume
- 509
- Issue
- 7502
- Pages
- 596-599
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2168933798
- Semantic Scholar
- 4b5b81db1162e43f2ee136bfe0096e9d4b851ae6
- Cited by
- 96
- References
- 32
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 7 · 2023: 4 · 2022: 5 · 2021: 12 · 2020: 7 · 2019: 7 · 2018: 10 · 2017: 11 · 2016: 9 · 2015: 12 · 2014: 5
- FWCI
- 6.13
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- CERN Document Server (European Organization for Nuclear Research) (submittedVersion)
- Max Planck Digital Library (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- arXiv (Cornell University)
- Funders
- Japan Society for the Promotion of Science (24000008)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle physics theoretical and experimental studies
- Keywords
- proton magnetic moment, double Penning trap, antiproton magnetic moment, matter-antimatter symmetry, CP violation, cyclotron frequency, nuclear magneton, fundamental physical constants, beyond the Standard Model
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Direct high-precision measurement of the magnetic moment of the proton. https://app.cochat.ai/papers/10.1038/nature13388
- The paper
- Mooser, A., Ulmer, S., Blaum, K., Franke, K., Kracke, H., Leiteritz, C., Quint, W., Rodegheri, C. C., Smorra, C., & Walz, J. (2014). Direct high-precision measurement of the magnetic moment of the proton. Nature. https://doi.org/10.1038/nature13388
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.