The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
A bioinspired omniphobic surface coating on medical devices prevents thrombosis and biofouling
Open accessAbstract
Thrombosis and biofouling of extracorporeal circuits and indwelling medical devices cause significant morbidity and mortality worldwide. We apply a bioinspired, omniphobic coating to tubing and catheters and show that it completely repels blood and suppresses biofilm formation. The coating is a covalently tethered, flexible molecular layer of perfluorocarbon, which holds a thin liquid film of medical-grade perfluorocarbon on the surface. This coating prevents fibrin attachment, reduces platelet adhesion and activation, suppresses biofilm formation and is stable under blood flow in vitro. Surface-coated medical-grade tubing and catheters, assembled into arteriovenous shunts and implanted in pigs, remain patent for at least 8 h without anticoagulation. This surface-coating technology could reduce the use of anticoagulants in patients and help to prevent thrombotic occlusion and biofouling of medical devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bioinspired self-repairing slippery surfaces with pressure-stable omniphobicity
Wong, T.-S., Kang, S. H., Tang, S. K. Y., Smythe, E. J., Hatton, B. D., Grinthal, A., & Aizenberg, J. (2011) · Nature · doi:10.1038/nature10447 · Cited by 4,134
Self-citationNew Challenges in Biomaterials
Peppas, N. A., & Langer, R. (1994) · Science · doi:10.1126/science.8134835 · Cited by 1,142
Liquid-infused structured surfaces with exceptional anti-biofouling performance
Epstein, A. K., Wong, T.-S., Belisle, R. A., Boggs, E. M., & Aizenberg, J. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201973109 · Cited by 928
Self-citationSurvival of Mammals Breathing Organic Liquids Equilibrated with Oxygen at Atmospheric Pressure
Clark, L. C., & Gollan, F. (1966) · Science · doi:10.1126/science.152.3730.1755 · Cited by 794
Bohn, H. F., & Federle, W. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0405885101 · Cited by 781
Kim, P., Kreder, M. J., Alvarenga, J., & Aizenberg, J. (2013) · Nano Letters · doi:10.1021/nl4003969 · Cited by 520
Self-citationVogel, N., Belisle, R. A., Hatton, B., Wong, T.-S., & Aizenberg, J. (2013) · Nature Communications · doi:10.1038/ncomms3176 · Cited by 439
Self-citationLarm, O., Larsson, R., & Olsson, P. (1983) · Biomaterials, Medical Devices, and Artificial Organs · doi:10.3109/10731198309118804 · Cited by 437
Plasma Surface Modification of Polymers: Relevance to Adhesion
(2014) · CRC Press eBooks · doi:10.1201/b12019 · Cited by 426
Perfluorocarbon‐Based Oxygen Carriers: Review of Products and Trials
Castro, C. I., & Briceno, J. C. (2010) · Artificial Organs · doi:10.1111/j.1525-1594.2009.00944.x · Cited by 334
An extracorporeal blood-cleansing device for sepsis therapy
Kang, J. H., Super, M., Yung, C. W., Cooper, R. M., Domansky, K., Graveline, A. R., Mammoto, T., Berthet, J. B., Tobin, H., Cartwright, M. J., et al. (2014) · Nature Medicine · doi:10.1038/nm.3640 · Cited by 321
Self-citationSurface modification of polymers: chemical, biological and surface analytical challenges
Ratner, B. D. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)99218-a · Cited by 303
Current strategies towards hemocompatible coatings
Werner, C., Maitz, M. F., & Sperling, C. (2007) · Journal of Materials Chemistry · doi:10.1039/b703416b · Cited by 258
Smith, R. S., Zhang, Z., Bouchard, M., Li, J., Lapp, H. S., Brotske, G. R., Lucchino, D. L., Weaver, D., Roth, L. A., Coury, A., et al. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004120 · Cited by 221
Sheep, pig, and human platelet-material interactions with model cardiovascular biomaterials
Goodman, S. L. (1999) · Journal of Biomedical Materials Research · Cited by 211
Surface wettability plays a significant role in gecko adhesion underwater
Stark, A. Y., Badge, I., Wucinich, N. A., Sullivan, T. W., Niewiarowski, P. H., & Dhinojwala, A. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1219317110 · Cited by 145
Adverse Drug Reaction Deaths Reported in United States Vital Statistics, 1999-2006
Shepherd, G., Mohorn, P., Yacoub, K., & May, D. W. (2012) · Annals of Pharmacotherapy · doi:10.1345/aph.1p592 · Cited by 138
In vitro hemocompatibility testing of UV-modified hyaluronan hydrogels
Amarnath, L. P., Srinivas, A., & Ramamurthi, A. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.08.008 · Cited by 132
Risk and benefit of low systemic heparinization during open heart operations
von Segesser, . K., Weiss, B. M., Pašić, M., Garcia, E., & Turina, M. I. (1994) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(94)92213-6 · Cited by 115
Unfractionated Heparin for Hemodialysis: Still the Best Option
Cronin, R. E., & Reilly, R. F. (2010) · Seminars in Dialysis · doi:10.1111/j.1525-139x.2010.00770.x · Cited by 103
Finkel, K. W., & Podoll, A. S. (2009) · Seminars in Dialysis · doi:10.1111/j.1525-139x.2008.00550.x · Cited by 83
Heparin‐Coated Equipment Reduces Complement Activation during Cardiopulmonary Bypass in the Pig
Nilsson, L., Storm, K., Thelin, S., Bagge, L., Hultman, J., Thorelius, J., & Nilsson, U. (1990) · Artificial Organs · doi:10.1111/j.1525-1594.1990.tb01591.x · Cited by 75
Perfluorocarbons Having a Short Dwell Time in the Liver
Clark, L. C., Becattini, F., Kaplan, S., Obrock, V., Cohen, D., & Becker, C. (1973) · Science · doi:10.1126/science.181.4100.680 · Cited by 67
Thiara, A., Andersen, V., Videm, V., Mollnes, T. E., Svennevig, K., Hoel, T. N., & Fiane, A. (2010) · Perfusion · doi:10.1177/0267659110362822 · Cited by 45
Polybetaine modification of PDMS microfluidic devices to resist thrombus formation in whole blood
Zhang, Z., Borenstein, J. T., Guiney, L. M., Miller, R. A., Sukavaneshvar, S., & Loose, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50302j · Cited by 42
Reser, D., Seifert, B., Klein, M., Dreizler, T., Hasenclever, P., Falk, V., & Starck, C. T. (2012) · Perfusion · doi:10.1177/0267659112454558 · Cited by 36
Use and safety of heparin-free maintenance hemodialysis in the USA
Shen, J. I., Mitani, A., Chang, T. I., & Winkelmayer, W. C. (2013) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gft067 · Cited by 32
Conn, G., Kidane, A. G., Punshon, G., Kannan, R. Y., Hamilton, G., & Seifalian, A. M. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.3.2.245 · Cited by 29
Palanzo, D. A., Zarro, D. L., Manley, N. J., Montesano, R. M., Quinn, M., Elmore, B.-A., Gustafson, P. A., & Castagna, J. M. (2001) · Perfusion · doi:10.1177/026765910101600403 · Cited by 24
Trillium Coating of Cardiopulmonary Bypass Circuits Improves Biocompatibility
Tevaearai, H. T., Mueller, X. M., Seigneul, I., Bürki, M., Horisberger, J., Stumpe, F., & von Segesser, L. K. (1999) · The International Journal of Artificial Organs · doi:10.1177/039139889902200907 · Cited by 20
Cited by
Robust self-cleaning surfaces that function when exposed to either air or oil
Lu, Y., Sathasivam, S., Song, J., Crick, C. R., Carmalt, C. J., & Parkin, I. P. (2015) · Science · doi:10.1126/science.aaa0946 · Cited by 1,808
A swarm of slippery micropropellers penetrates the vitreous body of the eye
Wu, Z., Troll, J., Jeong, H.-H., Wei, Q., Stang, M., Ziemssen, F., Wang, Z., Dong, M., Schnichels, S., Qiu, T., et al. (2018) · Science Advances · doi:10.1126/sciadv.aat4388 · Cited by 567
Mimicking biological functionality with polymers for biomedical applications
Green, J. J., & Elisseeff, J. H. (2016) · Nature · doi:10.1038/nature21005 · Cited by 495
Rapid Biofilm Eradication on Bone Implants Using Red Phosphorus and Near‐Infrared Light
Tan, L., Li, J., Liu, X., Cui, Z., Yang, X., Zhu, S., Li, Z., Yuan, X., Zheng, Y., Yeung, K. W. K., et al. (2018) · Advanced Materials · doi:10.1002/adma.201801808 · Cited by 495
Multifunctional “Hydrogel Skins” on Diverse Polymers with Arbitrary Shapes
Yu, Y., Yuk, H., Parada, G. A., Wu, Y., Liu, X., Nabzdyk, C. S., Youcef‐Toumi, K., Zang, J., & Zhao, X. (2019) · Advanced Materials · doi:10.1002/adma.201807101 · Cited by 482
Metadata
- Authors
- Leslie, D. C., Waterhouse, A., Berthet, J. B., Valentin, T. M., Watters, A. L., Jain, A., Kim, P., Hatton, B. D., Nedder, A., Donovan, K., Super, E. H., Howell, C., Johnson, C. P., Vu, T. L., Bolgen, D. E., Rifai, S., Hansen, A. R., Aizenberg, M., Super, M., Aizenberg, J., & Ingber, D. E.
- Venue
- Nature Biotechnology
- Published
- 2014-10-12
- Volume
- 32
- Issue
- 11
- Pages
- 1134-1140
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W2059148563
- Cited by
- 758
- References
- 30
- FWCI
- 19.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.