The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Analyzing proteome topology and function by automated multidimensional fluorescence microscopy
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A peripheral mononeuropathy in rat that produces disorders of pain sensation like those seen in man
Bennett, G. J., & Xie, Y.-K. (1988) · Pain · doi:10.1016/0304-3959(88)90209-6 · Cited by 5,376
Global analysis of protein localization in budding yeast
Huh, W.-K., Falvo, J. V., Gerke, L. C., Carroll, A. S., Howson, R. W., Weissman, J. S., & O'Shea, E. K. (2003) · Nature · doi:10.1038/nature02026 · Cited by 4,248 · cited 1×
“, or the location of the cellular proteome in intact yeas”
BackgroundA vision for the future of genomics research
Collins, F. S., Green, E. D., Guttmacher, A. E., Guyer, M. S., & on behalf of the US National Human Genome Research Institute (2003) · Nature · doi:10.1038/nature01626 · Cited by 1,752
Seventeen-colour flow cytometry: unravelling the immune system
Perfetto, S. P., Chattopadhyay, P. K., & Roederer, M. (2004) · Nature Reviews Immunology · doi:10.1038/nri1416 · Cited by 1,019
Least effort and the origins of scaling in human language
Cancho, R. F. I., & Solé, R. V. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0335980100 · Cited by 588
Cited by
Histopathological Image Analysis: A Review
Gurcan, M. N., Boucheron, L. E., Can, A., Madabhushi, A., Rajpoot, N. M., & Yener, B. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2034865 · Cited by 2,052
Highly multiplexed imaging of tumor tissues with subcellular resolution by mass cytometry
Giesen, C., Wang, H. A. O., Schapiro, D., Zivanovic, N., Jacobs, A., Hattendorf, B., Schüffler, P. J., Grolimund, D., Buhmann, J. M., Brandt, S., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2869 · Cited by 1,951
Deep profiling of mouse splenic architecture with CODEX multiplexed imaging
Goltsev, Y., Samusik, N., Kennedy-Darling, J., Bhate, S., Hale, M., Vazquez, G., Black, S., & Nolan, G. P. (2018) · Cell · doi:10.1016/j.cell.2018.07.010 · Cited by 1,501
“Approaches have been developed to overcome such limitations (Schubert et al., 2006; Gerdes et al., 2013), but these protocols have required multiple stain/ strip/wash cycles of the antibodies that can be time consuming or lead to sample degradation over the iterations.”
Multiplexed ion beam imaging of human breast tumors
Angelo, M., Bendall, S. C., Finck, R., Hale, M. B., Hitzman, C., Borowsky, A. D., Levenson, R. M., Lowe, J. B., Liu, S. D., Zhao, S., et al. (2014) · Nature Medicine · doi:10.1038/nm.3488 · Cited by 1,108
Micheva, K. D., & Smith, S. J. (2007) · Neuron · doi:10.1016/j.neuron.2007.06.014 · Cited by 787
Metadata
- Authors
- Schubert, W., Bonnekoh, B., Pommer, A. J., Philipsen, L., Böckelmann, R., Malykh, Y., Gollnick, H., Friedenberger, M., Bode, M., & Dress, A. W. M.
- Venue
- Nature Biotechnology
- Published
- 2006-10
- Volume
- 24
- Issue
- 10
- Pages
- 1270-1278
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W2114319457
- Cited by
- 479
- References
- 5
- FWCI
- 12.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analyzing proteome topology and function by automated multidimensional fluorescence microscopy. https://app.cochat.ai/papers/10.1038/nbt1250
- The paper
- Schubert, W., Bonnekoh, B., Pommer, A. J., Philipsen, L., Böckelmann, R., Malykh, Y., Gollnick, H., Friedenberger, M., Bode, M., & Dress, A. W. M. (2006). Analyzing proteome topology and function by automated multidimensional fluorescence microscopy. Nature Biotechnology. https://doi.org/10.1038/nbt1250
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.