The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Long-term multiple color imaging of live cells using quantum dot bioconjugates
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Semiconductor Nanocrystals as Fluorescent Biological Labels
Bruchez, M., Moronne, M., Gin, P., Weiss, S., & Alivisatos, A. P. (1998) · Science · doi:10.1126/science.281.5385.2013 · Cited by 8,613
Quantum Dot Bioconjugates for Ultrasensitive Nonisotopic Detection
Chan, W. C. W., & Nie, S. (1998) · Science · doi:10.1126/science.281.5385.2016 · Cited by 7,278
Quantum-dot-tagged microbeads for multiplexed optical coding of biomolecules
Han, M., Gao, X., Su, J. Z., & Nie, S. (2001) · Nature Biotechnology · doi:10.1038/90228 · Cited by 2,631
Luminescent quantum dots for multiplexed biological detection and imaging
Chan, W. C. W., Maxwell, D. J., Gao, X., Bailey, R. E., Han, M., & Nie, S. (2002) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00282-3 · Cited by 2,068
Self-Assembly of CdSe−ZnS Quantum Dot Bioconjugates Using an Engineered Recombinant Protein
Mattoussi, H., Mauro, J. M., Goldman, E. R., Anderson, G. P., Sundar, V. C., Mikulec, F. V., & Bawendi, M. G. (2000) · Journal of the American Chemical Society · doi:10.1021/ja002535y · Cited by 1,681
Self-citationGrowth of myxamoebae of the cellular slime mould Dictyostelium discoideum in axenic culture
Watts, D. J., & Ashworth, J. M. (1970) · Biochemical Journal · doi:10.1042/bj1190171 · Cited by 1,135
Avidin: A Natural Bridge for Quantum Dot-Antibody Conjugates
Goldman, E. R., Balighian, E. D., Mattoussi, H., Kuno, M. K., Mauro, J. M., Tran, P. T., & Anderson, G. P. (2002) · Journal of the American Chemical Society · doi:10.1021/ja0125570 · Cited by 518
Self-citationGoldman, E. R., Anderson, G. P., Tran, P. T., Mattoussi, H., Charles, P. T., & Mauro, J. M. (2002) · Analytical Chemistry · doi:10.1021/ac010662m · Cited by 411
Self-citationTomchik, K. J., & Devreotes, P. N. (1981) · Science · doi:10.1126/science.6259734 · Cited by 395
Intracellular localization of the P21rho proteins.
Adamson, P., Paterson, H. F., & Hall, A. (1992) · The Journal of cell biology · doi:10.1083/jcb.119.3.617 · Cited by 383
Properties of Fluorescent Semiconductor Nanocrystals and their Application to Biological Labeling
Michalet, X., Pinaud, F. F., Lacoste, T. D., Dahan, M., Bruchez, M. P., Alivisatos, A. P., & Weiss, S. (2001) · Single Molecules · doi:10.1002/1438-5171(200112)2:4<261::aid-simo261>3.0.co;2-p · Cited by 371
Intracellular oscillations and release of cyclic AMP from Dictyostelium cells
Gerisch, G., & Wick, U. (1975) · Biochemical and Biophysical Research Communications · doi:10.1016/s0006-291x(75)80102-1 · Cited by 305
MOLECULAR GENETICS OF SIGNAL TRANSDUCTION IN DICTYOSTELIUM
Parent, C. A., & Devreotes, P. N. (1996) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.65.070196.002211 · Cited by 269
Optical biosensors : present and future
Ligler, F. S., & Taitt, C. A. R. (2002) · Cited by 241
Mattoussi, H. M., Mauro, J. M., Goldman, E. R., Green, T. M., Anderson, G. P., Sundar, V. C., & Bawendi, M. G. (2001) · physica status solidi (b) · doi:10.1002/1521-3951(200103)224:1<277::aid-pssb277>3.0.co;2-c · Cited by 116
Self-citationFluorescent Protein Biosensors: Measurement of Molecular Dynamics in Living Cells
Giuliano, K. A., Post, P. L., Hahn, K. M., & Taylor, D. L. (1995) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.bb.24.060195.002201 · Cited by 109
Three-Color Imaging Using Fluorescent Proteins in Living Zebrafish Embryos
Finley, K. R., Davidson, A. E., & Ekker, S. C. (2001) · BioTechniques · doi:10.2144/01311st02 · Cited by 66
In Situ Biochemical Demonstration That P-Glycoprotein Is a Drug Efflux Pump with Broad Specificity
Chen, Y., & Simon, S. M. (2000) · The Journal of Cell Biology · doi:10.1083/jcb.148.5.863 · Cited by 49
Self-citationde Souza, N., & Simon, S. M. (2002) · Biochemistry · doi:10.1021/bi0258041 · Cited by 19
Self-citation
Cited by
Quantum Dots for Live Cells, in Vivo Imaging, and Diagnostics
Michalet, X., Pinaud, F. F., Bentolila, L. A., Tsay, J. M., Doose, S., Li, J. J., Sundaresan, G., Wu, A. M., Gambhir, S. S., & Weiss, S. (2005) · Science · doi:10.1126/science.1104274 · Cited by 7,790
Quantum dot bioconjugates for imaging, labelling and sensing
Medintz, I. L., Uyeda, H. T., Goldman, E. R., & Mattoussi, H. (2005) · Nature Materials · doi:10.1038/nmat1390 · Cited by 6,229
Self-citationIn vivo cancer targeting and imaging with semiconductor quantum dots
Gao, X., Cui, Y., Levenson, R. M., Chung, L. W. K., & Nie, S. (2004) · Nature Biotechnology · doi:10.1038/nbt994 · Cited by 4,772
Cancer nanotechnology: opportunities and challenges
Ferrari, M. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1566 · Cited by 4,558
Quantum dots versus organic dyes as fluorescent labels
Resch-Genger, U., Grabolle, M., Cavaliere-Jaricot, S., Nitschke, R., & Nann, T. (2008) · Nature Methods · doi:10.1038/nmeth.1248 · Cited by 3,833
Metadata
- Authors
- Jaiswal, J. K., Mattoussi, H., Mauro, J. M., & Simon, S. M.
- Venue
- Nature Biotechnology
- Published
- 2002-12-02
- Volume
- 21
- Issue
- 1
- Pages
- 47-51
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W2011032800
- Cited by
- 1,999
- References
- 19
- FWCI
- 52.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.