The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms
Abstract
Although the nonlinear optical effect known as second-harmonic generation (SHG) has been recognized since the earliest days of laser physics and was demonstrated through a microscope over 25 years ago, only in the past few years has it begun to emerge as a viable microscope imaging contrast mechanism for visualization of cell and tissue structure and function. Only small modifications are required to equip a standard laser-scanning two-photon microscope for second-harmonic imaging microscopy (SHIM). Recent studies of the three-dimensional in vivo structures of well-ordered protein assemblies, such as collagen, microtubules and muscle myosin, are beginning to establish SHIM as a nondestructive imaging modality that holds promise for both basic research and clinical pathology. Thus far the best signals have been obtained in a transmitted light geometry that precludes in vivo measurements on large living animals. This drawback may be addressed through improvements in the collection of SHG signals via an epi-illumination microscope configuration. In addition, SHG signals from certain membrane-bound dyes have been shown to be highly sensitive to membrane potential. Although this indicates that SHIM may become a valuable tool for probing cell physiology, the small signal size would limit the number of photons that could be collected during the course of a fast action potential. Better dyes and optimized microscope optics could ultimately lead to the imaging of neuronal electrical a…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“second harmonic generation (SHG) microscopy has emerged as a label-free imaging modality capable of visualizing collagen-rich structures within intact spheroids [259,260].”
From Modeling Tumor Microenvironment Complexity In Vitro: Spheroids as Physiologically Relevant Tumor Models and Strategies for Their Analysis (2025) · cites this paper as [260]
Citations
Cites
Zipfel, W. R., Williams, R. M., Christie, R. H., Nikitin, A. Y., Hyman, B. T., & Webb, W. W. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832308100 · Cited by 1,712
Campagnola, P. J., Millard, A. C., Terasaki, M., Hoppe, P. E., Malone, C. J., & Mohler, W. A. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75414-3 · Cited by 922
Self-citationZoumi, A., Yeh, A. T., & Tromberg, B. J. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.172368799 · Cited by 872
Dynamic imaging of collagen and its modulation in tumors in vivo using second-harmonic generation
Brown, E. B., McKee, T. D., DiTomaso, E., Pluen, A., Seed, B., Boucher, Y., & Jain, R. K. (2003) · Nature Medicine · doi:10.1038/nm879 · Cited by 844
High-Resolution Nonlinear Optical Imaging of Live Cells by Second Harmonic Generation
Campagnola, P. J., Wei, M.-D., Lewis, A., & Loew, L. M. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77165-1 · Cited by 504
Self-citationFreund, I., Deutsch, M., & Sprecher, A. (1986) · Biophysical Journal · doi:10.1016/s0006-3495(86)83510-x · Cited by 449
3-Dimensional imaging of collagen using second harmonic generation
Cox, G., Kable, E., Jones, A., Fraser, I., Manconi, F., & Gorrell, M. D. (2003) · Journal of Structural Biology · doi:10.1016/s1047-8477(02)00576-2 · Cited by 430
Polarization-Modulated Second Harmonic Generation in Collagen
Stoller, P. C., Reiser, K. M., Celliers, P. M., & Rubenchik, A. M. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75673-7 · Cited by 403
Membrane imaging by second-harmonic generation microscopy
Moreaux, L. C., Sandre, O., & Mertz, J. C. (2000) · Journal of the Optical Society of America B · doi:10.1364/josab.17.001685 · Cited by 346
Inoué, S. (1986) · Springer eBooks · doi:10.1007/978-1-4757-6925-8 · Cited by 343
Flagged first, then by citations
Research works printed but not linked: 3
- Sheppard, C.J.R., Kompfner, R., Gannaway, J. & Walsh, D. Scanning harmonic optical microscope. IEEE J. Quantum Electron. 13E, 100D (1977).
- Brown, E. et al. Dynamic imaging of collagen and its modulation in tumors in vivo using second harmonic generation. Nat. Med. 9, 796–800 (2003). · DOI
- Huang, J.Y., Lewis, A. & Loew, L.M. Non-linear optical properties of potential sensitive styryl dyes. Biophys. J. 53, 665–670 (1988). · DOI
Cited by
Sorted by citations
Items 401–500 of 1,000
Thickness dependence of optical second harmonic generation in collagen fibrils
Chu, S., Tai, S.-P., Chan, M., Sun, C., Hsiao, I.-C., Lin, C.-H., Chen, Y., & Lin, B.-L. (2007) · Optics Express · doi:10.1364/oe.15.012005 · Cited by 35
Wavelength- and Time-Dependence of Potentiometric Non-linear Optical Signals from Styryl Dyes
Millard, A. C., Jin, L., Wuskell, J. P., Boudreau, D. M., Lewis, A., & Loew, L. M. (2005) · The Journal of Membrane Biology · doi:10.1007/s00232-005-0823-y · Cited by 35
Self-citationThree distinct sarcomeric patterns of skeletal muscle revealed by SHG and TPEF Microscopy
Recher, G., Rouède, D., Richard, P., Simon, A., Bellanger, J.-J., & Tiaho, F. (2009) · Optics Express · doi:10.1364/oe.17.019763 · Cited by 34
Towards protein-crystal centering using second-harmonic generation (SHG) microscopy
Kissick, D. J., Dettmar, C. M., Becker, M., Mulichak, A. M., Cherezov, V., Ginell, S. L., Battaile, K. P., Keefe, L. J., Fischetti, R. F., & Simpson, G. J. (2013) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444913002746 · Cited by 34
RhoA is down-regulated at cell–cell contacts via p190RhoGAP-B in response to tensional homeostasis
Ponik, S. M., Trier, S. M., Wozniak, M. A., Eliceiri, K. W., & Keely, P. J. (2013) · Molecular Biology of the Cell · doi:10.1091/mbc.e12-05-0386 · Cited by 34
Nonlinear optical microscopy for drug delivery monitoring and cancer tissue imaging
Mouras, R., Rischitor, G., Downes, A., Salter, D. M., & Elfick, A. P. D. (2010) · Journal of Raman Spectroscopy · doi:10.1002/jrs.2622 · Cited by 34
Sahu, S. P., Mahigir, A., Chidester, B., Veronis, G., & Gartia, M. R. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b02239 · Cited by 34
Cui, N., Zhang, F., Zhao, Y., Yao, Y., Wang, Q., Dong, L., Zhang, H., Liu, S., Xu, J., & Zhang, H. (2019) · Nanoscale · doi:10.1039/c9nr08980b · Cited by 34
Optical Imaging of Beta-Amyloid Plaques in Alzheimer’s Disease
Luo, Z., Xu, H., Liu, L., Ohulchanskyy, T. Y., & Qu, J. (2021) · Biosensors · doi:10.3390/bios11080255 · Cited by 34
Polarization resolved second harmonic microscopy
Mazumder, N., Deka, G., Wu, W., Gogoi, A., Zhuo, G., & Kao, F. (2017) · Methods · doi:10.1016/j.ymeth.2017.06.012 · Cited by 34
Wang, B., Koenig, K., Riemann, I., Krieg, R., & Halbhuber, K. (2006) · Histochemistry and Cell Biology · doi:10.1007/s00418-006-0187-0 · Cited by 34
Femtosecond laser photodisruption of human trabecular meshwork: an in vitro study
Toyran, S., Liu, Y., Singha, S., Shan, S., Cho, M., Gordon, R. J., & Edward, D. P. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2005.02.001 · Cited by 34
Sun, T., Zhao, H., Hu, L., Shao, X., Lu, Z., Wang, Y., Ling, P., Li, Y., Zeng, K., & Chen, Q. (2024) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2024.01.018 · Cited by 34
Single-pulse CARS based multimodal nonlinear optical microscope for bioimaging
Kumar, S., Kamali, T., Levitte, J. M., Katz, O., Hermann, B. M., Werkmeister, R. M., Považay, B., Drexler, W., Unterhuber, A., & Silberberg, Y. R. (2015) · Optics Express · doi:10.1364/oe.23.013082 · Cited by 33
Zaręba, J. K., Białek, M. J., Janczak, J., Nyk, M., Zoń, J., & Samoc, M. J. (2015) · Inorganic Chemistry · doi:10.1021/acs.inorgchem.5b01939 · Cited by 33
Second Harmonic Generation Microscopy: A Tool for Quantitative Analysis of Tissues
Bueno, J. M., Ávila, F. J., & Artal, P. (2016) · InTech eBooks · doi:10.5772/63493 · Cited by 33
Yan, N., He, X., Tang, B. Z., & Wang, W. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.9b01156 · Cited by 33
Khajuria, D. K., Soliman, M., Elfar, J. C., Lewis, G. S., Abraham, T., Kamal, F., & Elbarbary, R. A. (2020) · Bone · doi:10.1016/j.bone.2020.115436 · Cited by 33
High-power, high repetition-rate, green-pumped, picosecond LBO optical parametric oscillator
Kienle, F., Teh, P. S., Lin, D., Alam, S.-U., Price, J. H. V., Hanna, D. C., Richardson, D. J., & Shepherd, D. P. (2012) · Optics Express · doi:10.1364/oe.20.007008 · Cited by 33
Mostaço-Guidolin, L. B., Sowa, M. G., Ridsdale, A., Pegoraro, A. F., Smith, M. S. D., Hewko, M. D., Kohlenberg, E. K., Schattka, B. J., Shiomi, M., Stolow, A., et al. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000059 · Cited by 32
New techniques in linear and non-linear laser optics in muscle research
Vanzi, F., Capitanio, M., Sacconi, L., Stringari, C., Cicchi, R., Canepari, M., Maffei, M., Piroddi, N., Poggesi, C., Nucciotti, V., et al. (2006) · Journal of Muscle Research and Cell Motility · doi:10.1007/s10974-006-9084-3 · Cited by 33
Chen, W., Hu, P., Ghazaryan, A. A., Chen, S., Tsai, T., & Dong, C. (2012) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2012.06.003 · Cited by 33
Saitou, T., Kiyomatsu, H., & Imamura, T. (2018) · Scientific Reports · doi:10.1038/s41598-018-21005-9 · Cited by 33
Zhuo, S., Yan, J., Chen, G., Shi, H., Zhu, X., Lu, J., Chen, J., & Xie, S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0038655 · Cited by 32
Visualization of the Cellulose Biosynthesis and Cell Integration into Cellulose Scaffolds
Brackmann, C., Bodin, A., Åkeson, M., Gatenholm, P., & Enejder, A. M. K. (2010) · Biomacromolecules · doi:10.1021/bm901153t · Cited by 32
Liu, Z., Speroni, L., Quinn, K. P., Alonzo, C., Pouli, D., Zhang, Y., Stuntz, E., Sonnenschein, C., Soto, A. M., & Georgakoudi, I. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.06.036 · Cited by 32
Intravital Multiphoton Imaging of the Bone and Bone Marrow Environment
Kim, J., & Bixel, M. G. (2019) · Cytometry Part A · doi:10.1002/cyto.a.23937 · Cited by 34
Multiphoton Microscopy of Live Tissues With Ultraviolet Autofluorescence
Li, C., Pitsillides, C. M., Runnels, J. M., Côté, D. C., & Lin, C. P. (2009) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2009.2031619 · Cited by 31
Gieseking, R. L. M. (2019) · Chemistry of Materials · doi:10.1021/acs.chemmater.9b01290 · Cited by 32
Neu, T. R., & Lawrence, J. R. (2004) · Methods in microbiology · doi:10.1016/s0580-9517(04)34004-3 · Cited by 32
Barsu, C., Fortrie, R., Nowika, K., Baldeck, P. L., Vial, J., Barsella, A., Fort, A. F., Hissler, M., Bretonnière, Y., Maury, O., et al. (2006) · Chemical Communications · doi:10.1039/b610557b · Cited by 32
Zhuo, G., Lee, H., Hsu, K.-J., Huttunen, M. J., Kauranen, M. O., Lin, Y.-Y., & Chu, S. (2014) · Journal of Microscopy · doi:10.1111/jmi.12108 · Cited by 31
Combs, C. A., SMIRNOV, A., Chess, D. J., McGavern, D. B., Schroeder, J., RILEY, J., KANG, S. S., Luger-Hamer, M., Gandjbakhche, A., Knutson, J. R., et al. (2010) · Journal of Microscopy · doi:10.1111/j.1365-2818.2010.03411.x · Cited by 31
Multimodal, label‐free nonlinear optical imaging for applications in biology and biomedical science
Mouras, R., Bagnaninchi, P., Downes, A., & Elfick, A. P. D. (2013) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4305 · Cited by 31
Park, C., Rhee, Y.-S., Vogt, F. G., Hayes, D., Zwischenberger, J. B., DeLuca, P. P., & Mansour, H. M. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.08.004 · Cited by 33
Ex vivo imaging and quantification of liver fibrosis using second-harmonic generation microscopy
Sun, T., Liu, Y., Sung, M.-C., Chen, H., Yang, C.-H., Hovhannisyan, V., Lin, W., Jeng, Y., Chen, W., Chiou, L., et al. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3427146 · Cited by 31
Perry, S. W., Schueckler, J. M., Burke, K. A., Arcuri, G. L., & Brown, E. B. (2013) · BMC Cancer · doi:10.1186/1471-2407-13-411 · Cited by 31
Phase Matching Using the Linear Electro-Optic Effect
Cui, Z., Liu, D., Miao, J., Yang, A., & Zhu, J. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.043901 · Cited by 31
Yang, B., Brazile, B. L., Jan, N., Hua, Y., Wei, J., & Sigal, I. A. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.10.106001 · Cited by 31
Multimodal multiphoton imaging for label-free monitoring of early gastric cancer
Li, L., Kang, D., Huang, Z., Zhan, Z., Feng, C., Zhou, Y., Tu, H., Zhuo, S., & Chen, J. (2019) · BMC Cancer · doi:10.1186/s12885-019-5497-4 · Cited by 31
Mathew, M. V., Santos, S. I. C. O., Zalvidea, D., & Loza‐Álvarez, P. (2009) · Review of Scientific Instruments · doi:10.1063/1.3142225 · Cited by 31
Abraham, T., Hirota, J. A., Wadsworth, S. J., & Knight, D. A. (2011) · Pulmonary Pharmacology & Therapeutics · doi:10.1016/j.pupt.2011.03.008 · Cited by 32
Adur, J. F., Pelegati, V. B., de Thomaz, A. A., D'Souza-Li, L., Assuncao, M. D. C., Bottcher-Luiz, F., Andrade, L. A., & Lenz-Cesar, C. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.8.081407 · Cited by 31
“Push-no-pull” porphyrins for second harmonic generation imaging
López‐Duarte, I., Reeve, J. E., Pérez‐Moreno, J., Boczarow, I., Depotter, G., Fleischhauer, J., Clays, K., & Anderson, H. L. (2013) · Chemical Science · doi:10.1039/c3sc22306j · Cited by 31
Hughes, M. W., Wu, P., Jiang, T., Lin, S., Dong, C., Li, A., Hsieh, F.-J., Widelitz, R. B., & Chuong, C. (2011) · Integrative Biology · doi:10.1039/c0ib00108b · Cited by 31
Huttunen, M. J., Hristu, R., Dumitru, A. V., Floroiu, I., Costache, M., & Stanciu, S. G. (2019) · Biomedical Optics Express · doi:10.1364/boe.11.000186 · Cited by 35
Imaging tissue engineering scaffolds using multiphoton microscopy
Sun, Y., Tan, H., Lin, S., Lee, M., Lin, T., Jee, S., Young, T., Lo, W., Chen, W., & Dong, C. (2007) · Microscopy Research and Technique · doi:10.1002/jemt.20537 · Cited by 30
Imaging cardiac extracellular matrices: a blueprint for regeneration
Jung, J. P., Squirrell, J. M., Lyons, G. E., Eliceiri, K. W., & Ogle, B. M. (2011) · Trends in biotechnology · doi:10.1016/j.tibtech.2011.12.001 · Cited by 30
Mazumder, N., Hu, C., Qiu, J., Foreman, M. R., Macias-Romero, C., Török, P., & Kao, F. (2013) · Methods · doi:10.1016/j.ymeth.2013.07.019 · Cited by 30
Throughput-Speed Product Augmentation for Scanning Fiber-Optic Two-Photon Endomicroscopy
Liang, W., Park, H., Li, K., Li, A., Chen, D., Guan, H., Yue, Y., Gau, Y. A., Bergles, D. E., Li, M.-J., et al. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3005067 · Cited by 30
Garner, B. W., Cai, T., Hu, Z., & Neogi, A. (2008) · Optics Express · doi:10.1364/oe.16.014910 · Cited by 30
Gu, M., Bao, H., & Kang, H. S. (2014) · Journal of Microscopy · doi:10.1111/jmi.12119 · Cited by 30
Selective imaging in second-harmonic-generation microscopy by polarization manipulation
Chu, S., Tai, S.-P., Sun, C., & Lin, C.-H. (2007) · Applied Physics Letters · doi:10.1063/1.2783207 · Cited by 30
Polarization anisotropy in fiber-optic second harmonic generation microscopy
Fu, L., & Gu, M. (2008) · Optics Express · doi:10.1364/oe.16.005000 · Cited by 30
Biochemical and pathological changes result from mutated Caveolin-3 in muscle
Coraspe, J. A. G., Weis, J., Anderson, M. E., Münchberg, U., Lorenz, K., Buchkremer, S., Carr, S., Zahedi, R. P., Brauers, E., Michels, H., et al. (2018) · Skeletal Muscle · doi:10.1186/s13395-018-0173-y · Cited by 30
High‐resolution two‐photon excitation microscopy of ocular tissues in porcine eye
Wang, B., Eitner, A., Lindenau, J., & Halbhuber, K. (2008) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20628 · Cited by 30
Nonlinear optical response of Au nanorods for broadband pulse modulation in bulk visible lasers
Wang, S., Zhang, Y., Xing, J., Liu, X., Yu, H., Lieto, A. D., Tonelli, M., Sum, T. C., Zhang, H., & Xiong, Q. (2015) · Applied Physics Letters · doi:10.1063/1.4934528 · Cited by 29
Quantitative phase imaging of stromal prognostic markers in pancreatic ductal adenocarcinoma
Fanous, M. J., Keikhosravi, A., Kajdacsy‐Balla, A., Eliceiri, K. W., & Popescu, G. (2020) · Biomedical Optics Express · doi:10.1364/boe.383242 · Cited by 29
Submillisecond second harmonic holographic imaging of biological specimens in three dimensions
Smith, D. R. R., Winters, D. G., & Bartels, R. A. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1306856110 · Cited by 29
Hermans, A., Kieninger, C., Koskinen, K., Wickberg, A., Solano, E., Dendooven, J., Kauranen, M. O., Clemmen, S., Wegener, M., Koos, C. G., et al. (2017) · Scientific Reports · doi:10.1038/srep44581 · Cited by 29
A Study on Image Quality in Polarization-Resolved Second Harmonic Generation Microscopy
Stanciu, S. G., Ávila, F. J., Hristu, R., & Bueno, J. M. (2017) · Scientific Reports · doi:10.1038/s41598-017-15257-0 · Cited by 29
Monaghan, M. G., Kroll, S., Brucker, S. Y., & Schenke‐Layland, K. (2016) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2016.0071 · Cited by 29
Sum-frequency spectroscopy and imaging of aligned helical polypeptides
Knoesen, A., Pakalnis, S., Wang, M., Wise, W. D., Lee, N., & Frank, C. W. (2004) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2004.837226 · Cited by 29
Tian, Y., Li, L., Zhou, Y., Wang, P., Zhou, H., Wu, J., Hu, Z., Yang, J., Kong, L., Xu, G., et al. (2009) · Crystal Growth & Design · doi:10.1021/cg801022h · Cited by 28
Diet-induced obesity skin changes monitored by in vivo SHG and ex vivo CARS microscopy
Haluszka, D., Lőrincz, K. K., Kiss, N., Szipöcs, R., Kuroli, E., Gyöngyösi, N., & Wikonkál, N. M. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.004480 · Cited by 28
Shirshin, E. A., Yakimov, B. P., Darvin, M. E., Omelyanenko, N. P., Rodionov, S. A., Gurfinkel, Y. I., Lademann, J. M., Fadeev, V. V., & Priezzhev, A. V. (2019) · Biochemistry (Moscow) · doi:10.1134/s0006297919140050 · Cited by 28
Molecule‐Membrane Interactions in Biological Cells Studied with Second Harmonic Light Scattering
Wilhelm, M. J., & Dai, H. (2019) · Chemistry - An Asian Journal · doi:10.1002/asia.201901406 · Cited by 28
Chen, C., & Khoo, I. C. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2021304118 · Cited by 28
Tripling the maximum imaging depth with third-harmonic generation microscopy
Yıldırım, M., Durr, N. J., & Ben‐Yakar, A. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.9.096013 · Cited by 28
Winters, D. G., Smith, D. R. R., Schlup, P., & Bartels, R. A. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.002004 · Cited by 28
Amitonova, L. V., Александрович, Л. А., Ivashkina, O. I., Roshchina, M. A., Fedotov, A. B., Anokhin, K. V., & Zheltikov, A. M. (2011) · Applied Physics Letters · doi:10.1063/1.3664345 · Cited by 28
Nonlinear optical potentiometric dyes optimized for imaging with 1064-nm light
Teisseyre, T. Z., Millard, A. C., Yan, P., Wuskell, J. P., Wei, M.-D., Lewis, A., & Loew, L. M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2772276 · Cited by 28
Self-citationKaneshiro, J., Watanabe, T. M., Fujita, H., & Ichimura, T. (2016) · Applied Optics · doi:10.1364/ao.55.001082 · Cited by 28
Radaelli, F., D’Alfonso, L., Collini, M., Mingozzi, F., Marongiu, L., Granucci, F., Zanoni, I., Chirico, G. G., & Sironi, L. (2017) · Scientific Reports · doi:10.1038/s41598-017-17726-y · Cited by 28
Wang, G., Sun, Y., Chen, Y., Gao, Q., Peng, D., Lin, H., Zhan, Z., Liu, Z., & Zhuo, S. (2020) · Journal of Biophotonics · doi:10.1002/jbio.202000050 · Cited by 28
The 3D structure of the tectorial membrane determined by second-harmonic imaging microscopy
Gueta, R., TAL, E., Silberberg, Y. R., & Rousso, I. Y. (2007) · Journal of Structural Biology · doi:10.1016/j.jsb.2007.03.002 · Cited by 28
Sinclair, E. B., Andarawis‐Puri, N., Ros, S. J., Laudier, D. M., Jepsen, K. J., & Hausman, M. R. (2012) · Muscle & Nerve · doi:10.1002/mus.23443 · Cited by 27
Enhanced Second Harmonic Generation Efficiency via Wavefront Shaping
Thompson, J. V., Hokr, B. H., Throckmorton, G. A., Wang, D., Scully, M. O., & Yakovlev, V. V. (2017) · ACS Photonics · doi:10.1021/acsphotonics.7b00379 · Cited by 27
Porphyrin Dyes for Nonlinear Optical Imaging of Live Cells
Khadria, A., Fleischhauer, J., Boczarow, I., Wilkinson, J. D., Kohl, M. M., & Anderson, H. L. (2018) · iScience · doi:10.1016/j.isci.2018.05.015 · Cited by 27
Rentchler, E. C., Gant, K. L., Drapkin, R., Patankar, M. S., & Campagnola, P. J. (2019) · Cancers · doi:10.3390/cancers11111805 · Cited by 29
Self-citationPoulikakos, L. V., Lawrence, M., Barton, D. R., Jeffrey, S. S., & Dionne, J. A. (2020) · ACS Photonics · doi:10.1021/acsphotonics.0c01303 · Cited by 27
Hoang, V. T., Boussafa, Y., Sader, L., Février, S., Couderc, V., & Wetzel, B. (2022) · Frontiers in Photonics · doi:10.3389/fphot.2022.940902 · Cited by 27
Tian, L., Qu, J., Guo, Z., Jin, Y., Meng, Y., & Deng, X. (2010) · Journal of Applied Physics · doi:10.1063/1.3474667 · Cited by 27
Duboisset, J., Deniset‐Besseau, A., Bénichou, E., Russier‐Antoine, I., Lascoux, N., Jonin, C., Hache, F., Schanne‐Klein, M., & Brevet, P. (2013) · The Journal of Physical Chemistry B · doi:10.1021/jp312574q · Cited by 27
Advanced Methods in Fluorescence Microscopy
Fritzky, L., & Lagunoff, D. (2013) · Analytical Cellular Pathology · doi:10.1155/2013/569326 · Cited by 27
Teulon, C., Tidu, A., Portier, F., Mosser, G., & Schanne‐Klein, M. (2016) · Optics Express · doi:10.1364/oe.24.016084 · Cited by 27
Leray, A., Leroy, L., Grand, Y. L., Odin, C., Renault, A., Vié, V., Rouède, D., Mallegol, T., Mongin, O., Werts, M. H. V., et al. (2004) · Langmuir · doi:10.1021/la0491706 · Cited by 27
Use of a single-mode fiber coupler for second-harmonic-generation microscopy
Fu, L., Gan, X. S., & Gu, M. (2005) · Optics Letters · doi:10.1364/ol.30.000385 · Cited by 27
Ni, M., Zhuo, S., Iliescu, C., So, P. T. C., Mehta, J. S., Yu, H., & Hauser, C. A. E. (2019) · Journal of Biophotonics · doi:10.1002/jbio.201900065 · Cited by 26
Xydias, D., Ziakas, G., Psilodimitrakopoulos, S., Lemonis, A., Bagli, E., Fotsis, T., Gravanis, A., Tzeranis, D. S., & Stratakis, E. I. (2020) · Biomedical Optics Express · doi:10.1364/boe.411501 · Cited by 26
Zhang, C., Lin, F., Zhang, Y., Yang, H., Lin, D., He, J., Liao, C., Weng, X., Liu, L., Wang, Y., et al. (2023) · Nano Letters · doi:10.1021/acs.nanolett.3c01903 · Cited by 26
Abraham, T., Kayra, D., McManus, B. M., & Scott, A. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2012.05.004 · Cited by 26
ADVANCED OPTICAL TECHNIQUES TO EXPLORE BRAIN STRUCTURE AND FUNCTION
Silvestri, L., Mascaro, A. L. A., Lotti, J., Sacconi, L., & Pavone, F. S. (2012) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545812300029 · Cited by 26
Multiphoton autofluorescence and second-harmonic generation imaging of the tooth
Chen, M.-H., Chen, W., Sun, Y., Fwu, P. T., & Dong, C. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2812710 · Cited by 26
Wu, X., Chen, G., Qiu, J., Lu, J., Zhu, W., Chen, J., Zhuo, S., & Yan, J. (2016) · Oncology Letters · doi:10.3892/ol.2016.4472 · Cited by 26
Gieseking, R. L. M., Ensley, T. R., Hu, H., Hagan, D. J., Risko, C. M., Stryland, E. W. V., & Brédas, J. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b04377 · Cited by 26
Effect of crosslinking in cartilage-like collagen microstructures
Chen, Y., Chen, M., Gaffney, E. A., & Brown, C. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.10.006 · Cited by 26
Farid, M., Morishige, N., Lam, L., Wahlert, A. J., Steinert, R. F., & Jester, J. V. (2008) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.08-1983 · Cited by 26
When light meets biology – how the specimen affects quantitative microscopy
Reiche, M. A., Aaron, J., Boehm, U., DeSantis, M. C., Hobson, C. M., Khuon, S., Lee, R., & Chew, T. (2022) · Journal of Cell Science · doi:10.1242/jcs.259656 · Cited by 26
Miniaturized video-rate epi-third-harmonic-generation fiber-microscope
Chia, S., Yu, C., Lin, C.-H., Cheng, N.-C., Liu, T., Chan, M., Chen, I.-H., & Sun, C. (2010) · Optics Express · doi:10.1364/oe.18.017382 · Cited by 25
Metadata
- Authors
- Campagnola, P. J., & Loew, L. M.
- Affiliations
- UConn Health (US)
- Corresponding author
- Loew, Leslie M
- Venue
- Nature Biotechnology
- Published
- 2003-10-31
- Volume
- 21
- Issue
- 11
- Pages
- 1356-1360
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W2077572701
- Cited by
- 1,326
- References
- 29
- Citations by year
- 2026: 37 · 2025: 42 · 2024: 43 · 2023: 50 · 2022: 55 · 2021: 55 · 2020: 67 · 2019: 79 · 2018: 55 · 2017: 67 · 2016: 73 · 2015: 79 · 2014: 61 · 2013: 77 · 2012: 72
- FWCI
- 3.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Biotechnology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r21rr013472-02)
- Office of Naval Research
- National Institute of Biomedical Imaging and Bioengineering (R01EB00196)
- National Center for Research Resources (R21 RR13472)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Cell Image Analysis Techniques
- Keywords
- second harmonic generation, nonlinear optical microscopy, collagen imaging, microtubules, myosin, membrane potential, neuronal electrical activity, in vivo imaging
- MeSH terms
- Action Potentials, Cell Membrane, Cells, Image Enhancement, Membrane Potentials, Proteins, Microscopy, Confocal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review