The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms
Abstract
Although the nonlinear optical effect known as second-harmonic generation (SHG) has been recognized since the earliest days of laser physics and was demonstrated through a microscope over 25 years ago, only in the past few years has it begun to emerge as a viable microscope imaging contrast mechanism for visualization of cell and tissue structure and function. Only small modifications are required to equip a standard laser-scanning two-photon microscope for second-harmonic imaging microscopy (SHIM). Recent studies of the three-dimensional in vivo structures of well-ordered protein assemblies, such as collagen, microtubules and muscle myosin, are beginning to establish SHIM as a nondestructive imaging modality that holds promise for both basic research and clinical pathology. Thus far the best signals have been obtained in a transmitted light geometry that precludes in vivo measurements on large living animals. This drawback may be addressed through improvements in the collection of SHG signals via an epi-illumination microscope configuration. In addition, SHG signals from certain membrane-bound dyes have been shown to be highly sensitive to membrane potential. Although this indicates that SHIM may become a valuable tool for probing cell physiology, the small signal size would limit the number of photons that could be collected during the course of a fast action potential. Better dyes and optimized microscope optics could ultimately lead to the imaging of neuronal electrical a…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“second harmonic generation (SHG) microscopy has emerged as a label-free imaging modality capable of visualizing collagen-rich structures within intact spheroids [259,260].”
From Modeling Tumor Microenvironment Complexity In Vitro: Spheroids as Physiologically Relevant Tumor Models and Strategies for Their Analysis (2025) · cites this paper as [260]
Citations
Cites
Zipfel, W. R., Williams, R. M., Christie, R. H., Nikitin, A. Y., Hyman, B. T., & Webb, W. W. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832308100 · Cited by 1,712
Campagnola, P. J., Millard, A. C., Terasaki, M., Hoppe, P. E., Malone, C. J., & Mohler, W. A. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75414-3 · Cited by 922
Self-citationZoumi, A., Yeh, A. T., & Tromberg, B. J. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.172368799 · Cited by 872
Dynamic imaging of collagen and its modulation in tumors in vivo using second-harmonic generation
Brown, E. B., McKee, T. D., DiTomaso, E., Pluen, A., Seed, B., Boucher, Y., & Jain, R. K. (2003) · Nature Medicine · doi:10.1038/nm879 · Cited by 844
High-Resolution Nonlinear Optical Imaging of Live Cells by Second Harmonic Generation
Campagnola, P. J., Wei, M.-D., Lewis, A., & Loew, L. M. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77165-1 · Cited by 504
Self-citationFreund, I., Deutsch, M., & Sprecher, A. (1986) · Biophysical Journal · doi:10.1016/s0006-3495(86)83510-x · Cited by 449
3-Dimensional imaging of collagen using second harmonic generation
Cox, G., Kable, E., Jones, A., Fraser, I., Manconi, F., & Gorrell, M. D. (2003) · Journal of Structural Biology · doi:10.1016/s1047-8477(02)00576-2 · Cited by 430
Polarization-Modulated Second Harmonic Generation in Collagen
Stoller, P. C., Reiser, K. M., Celliers, P. M., & Rubenchik, A. M. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75673-7 · Cited by 403
Membrane imaging by second-harmonic generation microscopy
Moreaux, L. C., Sandre, O., & Mertz, J. C. (2000) · Journal of the Optical Society of America B · doi:10.1364/josab.17.001685 · Cited by 346
Inoué, S. (1986) · Springer eBooks · doi:10.1007/978-1-4757-6925-8 · Cited by 343
Flagged first, then by citations
Research works printed but not linked: 3
- Sheppard, C.J.R., Kompfner, R., Gannaway, J. & Walsh, D. Scanning harmonic optical microscope. IEEE J. Quantum Electron. 13E, 100D (1977).
- Brown, E. et al. Dynamic imaging of collagen and its modulation in tumors in vivo using second harmonic generation. Nat. Med. 9, 796–800 (2003). · DOI
- Huang, J.Y., Lewis, A. & Loew, L.M. Non-linear optical properties of potential sensitive styryl dyes. Biophys. J. 53, 665–670 (1988). · DOI
Cited by
Sorted by citations
Deep tissue two-photon microscopy
Helmchen, F., & Denk, W. T. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,288
Upconversion Nanoparticles: Design, Nanochemistry, and Applications in Theranostics
Chen, G., Qiu, H., Prasad, P. N., & Chen, X. S. (2014) · Chemical Reviews · doi:10.1021/cr400425h · Cited by 2,746
Fluorescence Lifetime Measurements and Biological Imaging
Berezin, M. Y., & Achilefu, S. (2010) · Chemical Reviews · doi:10.1021/cr900343z · Cited by 2,463
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Nanochemistry and Nanomedicine for Nanoparticle-based Diagnostics and Therapy
Chen, G., Roy, I., Yang, C., & Prasad, P. N. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00148 · Cited by 1,528
Aligned Collagen Is a Prognostic Signature for Survival in Human Breast Carcinoma
Conklin, M. W., Eickhoff, J. C., Riching, K. M., Pehlke, C. A., Eliceiri, K. W., Provenzano, P. P., Friedl, A., & Keely, P. J. (2011) · American Journal Of Pathology · doi:10.1016/j.ajpath.2010.11.076 · Cited by 1,321
Rezakhaniha, R., Agianniotis, A., Schrauwen, J. T. C., Griffa, A., Sage, D., Bouten, C. V. C., van de Vosse, F. N., Unser, M. A., & Stergiopulos, N. (2011) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-011-0325-z · Cited by 1,104
Second harmonic generation microscopy for quantitative analysis of collagen fibrillar structure
Chen, X., Nadiarynkh, O., Plotnikov, S., & Campagnola, P. J. (2012) · Nature Protocols · doi:10.1038/nprot.2012.009 · Cited by 985
Self-citationChemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy
Evans, C. L., Potma, E. O., Puoris'haag, M., Côté, D., Lin, C. P., & Xie, X. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508282102 · Cited by 957
Coherent Nonlinear Optical Imaging: Beyond Fluorescence Microscopy
Min, W., Freudiger, C. W., Lü, S., & Xie, X. S. (2011) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.012809.103512 · Cited by 597
Advanced Fluorescence Microscopy Techniques—FRAP, FLIP, FLAP, FRET and FLIM
Ishikawa-Ankerhold, H. C., Ankerhold, R., & Drummen, G. P. C. (2012) · Molecules · doi:10.3390/molecules17044047 · Cited by 562
Boskey, A. L., & Coleman, R. M. (2010) · Journal of Dental Research · doi:10.1177/0022034510377791 · Cited by 599
Mode matching in multiresonant plasmonic nanoantennas for enhanced second harmonic generation
Celebrano, M., Wu, X., Baselli, M., Großmann, S., Biagioni, P., Locatelli, A., Angelis, C. D., Cerullo, G., Osellame, R., Hecht, B., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.69 · Cited by 553
Characterization of the Myosin-Based Source for Second-Harmonic Generation from Muscle Sarcomeres
Plotnikov, S. V., Millard, A. C., Campagnola, P. J., & Mohler, W. A. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.071555 · Cited by 444
Self-citationStringari, C., Cinquin, A., Cinquin, O., Digman, M. A., Donovan, P. J., & Gratton, E. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1108161108 · Cited by 445
Skala, M. C., Riching, K. M., Bird, D. K., Gendron‐Fitzpatrick, A., Eickhoff, J. C., Eliceiri, K. W., Keely, P. J., & Ramanujam, N. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2717503 · Cited by 381
Probing Ferroelectrics Using Optical Second Harmonic Generation
Denev, S., Lummen, T. T. A., Barnes, E., Kumar, A., & Gopalan, V. (2011) · Journal of the American Ceramic Society · doi:10.1111/j.1551-2916.2011.04740.x · Cited by 381
Second harmonic generating (SHG) nanoprobes for in vivo imaging
Pantazis, P., Maloney, J. R., Wu, D., & Fraser, S. E. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1004748107 · Cited by 340
Minimally invasive high-speed imaging of sarcomere contractile dynamics in mice and humans
Llewellyn, M. E., Barretto, R. P. J., Delp, S. L., & Schnitzer, M. J. (2008) · Nature · doi:10.1038/nature07104 · Cited by 335
Two-photon fluorescence excitation and related techniques in biological microscopy
Diaspro, A., Chirico, G. G., & Collini, M. (2005) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583505004129 · Cited by 318
Coherent Anti-Stokes Raman Scattering Imaging of Axonal Myelin in Live Spinal Tissues
Wang, H., Fu, Y., Zickmund, P., Shi, R., & Cheng, J. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.061911 · Cited by 317
A live cell reporter of exosome secretion and uptake reveals pathfinding behavior of migrating cells
Sung, B. H., von Lersner, A. K., Guerrero, J. F., Krystofiak, E., Inman, D. R., Pelletier, R., Zijlstra, A., Ponik, S. M., & Weaver, A. M. (2020) · Nature Communications · doi:10.1038/s41467-020-15747-2 · Cited by 313
Picot, A., D’Aléo, A., Baldeck, P. L., Grichine, A., Alain Duperray, B., Andraud, C., & Maury, O. (2008) · Journal of the American Chemical Society · doi:10.1021/ja076837c · Cited by 312
Single Cell Optical Imaging and Spectroscopy
Stender, A. S., Marchuk, K., Liu, C., Sander, S., Meyer, M. W., Smith, E. A., Neupane, B. B., Wang, G., Li, J., Cheng, J., et al. (2013) · Chemical Reviews · doi:10.1021/cr300336e · Cited by 298
Atomically phase-matched second-harmonic generation in a 2D crystal
Zhao, M., Ye, Z., Suzuki, R., Ye, Y., Zhu, H., Xiao, J., Wang, Y., Iwasa, Y., & Zhang, X. (2016) · Light Science & Applications · doi:10.1038/lsa.2016.131 · Cited by 298
Advances in Light Microscopy for Neuroscience
Wilt, B. A., Burns, L. D., Ho, E. T. W., Ghosh, K. K., Mukamel, E. A., & Schnitzer, M. J. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135540 · Cited by 286
Coherent anti‐Stokes Raman Scattering Microscopy
Mueller, M., & Zumbusch, A. (2007) · ChemPhysChem · doi:10.1002/cphc.200700202 · Cited by 277
Second-Harmonic Imaging Microscopy of Normal Human and Keratoconus Cornea
Morishige, N., Wahlert, A. J., Kenney, M. C., Brown, D. J., Kawamoto, K., Chikama, T.-I., Nishida, T., & Jester, J. V. (2007) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-1177 · Cited by 274
Intravital imaging by simultaneous label-free autofluorescence-multiharmonic microscopy
You, S., Tu, H., Chaney, E. J., Sun, Y., Zhao, Y., Bower, A. J., Liu, Y.-Z., Marjanovic, M., Sinha, S., Pu, Y., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-04470-8 · Cited by 271
Alali, S., & Vitkin, I. A. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.6.061104 · Cited by 269
Nonlinear Optical Properties of Core-Shell Nanocavities for Enhanced Second-Harmonic Generation
Pu, Y., Grange, R., Hsieh, C., & Psaltis, D. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.207402 · Cited by 263
Nadiarnykh, O., LaComb, R. B., BREWER, M. A., & Campagnola, P. J. (2010) · BMC Cancer · doi:10.1186/1471-2407-10-94 · Cited by 265
Self-citationEstimation of helical angles of myosin and collagen by second harmonic generation imaging microscopy
Tiaho, F., Recher, G., & Rouède, D. (2007) · Optics Express · doi:10.1364/oe.15.012286 · Cited by 255
Webster, M. T., Manor, U., Lippincott‐Schwartz, J., & Fan, C. (2015) · Cell stem cell · doi:10.1016/j.stem.2015.11.005 · Cited by 248
Fragala, M. S., Kenny, A. M., & Kuchel, G. A. (2015) · Sports Medicine · doi:10.1007/s40279-015-0305-z · Cited by 246
Principles of two-photon excitation fluorescence microscopy and other nonlinear imaging approaches
Oheim, M., Michael, D. J., Geisbauer, M., Madsen, D., & Chow, R. H.-P. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.07.005 · Cited by 242
Lee, L. C., & Lo, K. K. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00629 · Cited by 255
DETECTING MICRODOMAINS IN INTACT CELL MEMBRANES
Lagerholm, B. C., Weinreb, G. E., Jacobson, K., & Thompson, N. L. (2004) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.56.092503.141211 · Cited by 224
Upconversion Nanoparticles: A Versatile Solution to Multiscale Biological Imaging
Wu, X., Chen, G., Shen, J., Li, Z., Zhang, Y., & Han, G. (2014) · Bioconjugate Chemistry · doi:10.1021/bc5003967 · Cited by 219
Li, J., Hu, G., Shi, L., He, N., Li, D., Shang, Q., Zhang, Q., Fu, H., Zhou, L., Xiong, W. H., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-26818-3 · Cited by 217
Drifka, C. R., Loeffler, A. G., Mathewson, K., Keikhosravi, A., Eickhoff, J. C., Liu, Y., Weber, S. M., Kao, W. J., & Eliceiri, K. W. (2016) · Oncotarget · doi:10.18632/oncotarget.12772 · Cited by 218
Lin, S., Wu, R.-J., Tan, H., Lo, W., Lin, W., Young, T., Hsu, C., Chen, J., Jee, S., & Dong, C. (2005) · Optics Letters · doi:10.1364/ol.30.002275 · Cited by 215
Scoring of collagen organization in healthy and diseased human dermis by multiphoton microscopy
Cicchi, R., Kapsokalyvas, D., GIORGI, V. D., Maio, V., Wiechen, A. V., Massi, D., Lotti, T., & Pavone, F. S. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910062 · Cited by 211
Two-Photon and Second Harmonic Microscopy in Clinical and Translational Cancer Research
Perry, S. W., Burke, R. M., & Brown, E. B. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0512-9 · Cited by 209
Multiresonant Broadband Optical Antennas As Efficient Tunable Nanosources of Second Harmonic Light
Aouani, H., Navarro‐Cía, M., Rahmani, M., Sidiropoulos, T. P. H., Hong, M., Oulton, R. F., & Maier, S. A. (2012) · Nano Letters · doi:10.1021/nl302665m · Cited by 206
Imaging stem-cell-driven regeneration in mammals
Schroeder, T. (2008) · Nature · doi:10.1038/nature07043 · Cited by 206
Two‐photon microscopy of deep intravital tissues and its merits in clinical research
Wang, B., König, K., & Halbhuber, K. J. (2009) · Journal of Microscopy · doi:10.1111/j.1365-2818.2009.03330.x · Cited by 204
Optical contrast agents and imaging systems for detection and diagnosis of cancer
Pierce, M. C., Javier, D. J., & Richards-Kortum, R. R. (2008) · International Journal of Cancer · doi:10.1002/ijc.23858 · Cited by 211
Characterization of photodamage in coherent anti-Stokes Raman scattering microscopy
Fu, Y., Wang, H., Shi, R., & Cheng, J. (2006) · Optics Express · doi:10.1364/oe.14.003942 · Cited by 200
Provenzano, P. P., Eliceiri, K. W., & Keely, P. J. (2008) · Clinical & Experimental Metastasis · doi:10.1007/s10585-008-9204-0 · Cited by 202
In vivo imaging of the diseased nervous system
Misgeld, T., & Kerschensteiner, M. (2006) · Nature reviews. Neuroscience · doi:10.1038/nrn1905 · Cited by 198
Bao, R., Huang, L., Andrade, J., Tan, W., Kibbe, W. A., Jiang, H., & Feng, G. (2014) · Cancer Informatics · doi:10.4137/cin.s13779 · Cited by 215
Fluorescence Microscopy: A Concise Guide to Current Imaging Methods
Combs, C. A., & Shroff, H. (2017) · Current Protocols in Neuroscience · doi:10.1002/cpns.29 · Cited by 194
Gailhouste, L., Grand, Y. L., Odin, C., Guyader, D., Turlin, B., Ezan, F., Désille, Y., Guilbert, T., Bessard, A., Frémin, C., et al. (2010) · Journal of Hepatology · doi:10.1016/j.jhep.2009.12.009 · Cited by 204
Zhang, Y., Wen, J., Zhu, S. N., & Xiao, M. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.183901 · Cited by 191
Navab, R., Strumpf, D., To, C., Pasko, E., Kim, K. S., Park, C., Hai, J., Liu, J., Jonkman, J. E. N., Barczyk, M., et al. (2015) · Oncogene · doi:10.1038/onc.2015.254 · Cited by 216
Multi-photon excitation microscopy
Diaspro, A., Bianchini, P., Vicidomini, G., Faretta, M., Ramoino, P., & Usai, C. (2006) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-5-36 · Cited by 186
Discrimination of basal cell carcinoma from normal dermal stroma by quantitative multiphoton imaging
Lin, S., Jee, S., Kuo, C.-J., Wu, R.-J., Lin, W., Chen, J., Liao, Y., Hsu, C., Tsai, T., Chen, Y., et al. (2006) · Optics Letters · doi:10.1364/ol.31.002756 · Cited by 185
Three-dimensional harmonic holographic microcopy using nanoparticles as probes for cell imaging
Hsieh, C., Grange, R., Pu, Y., & Psaltis, D. (2009) · Optics Express · doi:10.1364/oe.17.002880 · Cited by 183
Multimodal nonlinear optical microscopy
Yue, S., Slipchenko, M. N., & Cheng, J. (2011) · Laser & Photonics Review · doi:10.1002/lpor.201000027 · Cited by 187
Chen, D., Liu, Z., Liu, W., Fu, M., Jiang, W., Xu, S., Wang, G., Chen, F., Lu, J., Chen, H., et al. (2021) · Nature Communications · doi:10.1038/s41467-020-20429-0 · Cited by 185
Zhang, Y., Akins, M. L., Murari, K., Xi, J., Li, M.-J., Luby‐Phelps, K., Mahendroo, M., & Li, X. D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1121495109 · Cited by 186
Lanthanide Complexes for Nonlinear Optics: From Fundamental Aspects to Applications
Andraud, C., & Maury, O. (2009) · European Journal of Inorganic Chemistry · doi:10.1002/ejic.200900534 · Cited by 180
Correlative Super-Resolution Microscopy: New Dimensions and New Opportunities
Hauser, M., Wojcik, M., Kim, D., Mahmoudi, M., Li, W., & Xu, K. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00604 · Cited by 179
Wang, Y., Wu, Q., Chen, J., & Chen, G. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.03.035 · Cited by 176
Zhou, Z.-H., Ji, C., Xiao, H., Zhao, H., Cui, Y., & Bian, X. (2017) · Journal of Cancer · doi:10.7150/jca.18466 · Cited by 179
Metzger, B., Hentschel, M., Schumacher, T., Lippitz, M., Ye, X., Murray, C. B., Knabe, B., Buse, K., & Giessen, H. W. (2014) · Nano Letters · doi:10.1021/nl500913t · Cited by 172
Molecular and tissue alterations of collagens in fibrosis
Ricard‐Blum, S., Baffet, G., & Théret, N. (2018) · Matrix Biology · doi:10.1016/j.matbio.2018.02.004 · Cited by 179
Wilson, E. H., Harris, T. H., Mrass, P., John, B., Wojno, E. D. T., Wu, G. F., Pepper, M., Wherry, E. J., Dzierzinski, F., Roos, D. S., et al. (2009) · Immunity · doi:10.1016/j.immuni.2008.12.013 · Cited by 167
Le, T. T., Langohr, I. M., Locker, M. J., Sturek, M. S., & Cheng, J. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2795437 · Cited by 168
Production and Assessment of Decellularized Pig and Human Lung Scaffolds
Nichols, J. E., Niles, J. A., Riddle, M., Vargas, G., Shilagard, T., Ma, L., Edward, K., Francesca, S. L., Sakamoto, J. H., Vega, S. P., et al. (2013) · Tissue Engineering Part A · doi:10.1089/ten.tea.2012.0250 · Cited by 166
Harnessing non-destructive 3D pathology
Liu, J. T. C., Glaser, A. K., Bera, K., True, L. D., Reder, N. P., Eliceiri, K. W., & Madabhushi, A. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00681-x · Cited by 160
Scattering compensation by focus scanning holographic aberration probing (F-SHARP)
Papadopoulos, I. N., Jouhanneau, J.-S., Poulet, J. F. A., & Judkewitz, B. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.252 · Cited by 162
Collagen morphology and texture analysis: from statistics to classification
Mostaço-Guidolin, L. B., Ko, A. C. ‐., Wang, F., Xiang, B., Hewko, M. D., Tian, G., Major, A. A., Shiomi, M., & Sowa, M. G. (2013) · Scientific Reports · doi:10.1038/srep02190 · Cited by 163
Haupert, L. M., & Simpson, G. J. (2008) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.59.032607.093712 · Cited by 163
Second harmonic generation microscopy: a powerful tool for bio-imaging
Aghigh, A., Bancelin, S., Rivard, M., Pinsard, M., Ibrahim, H., & Légaré, F. (2023) · Biophysical Reviews · doi:10.1007/s12551-022-01041-6 · Cited by 162
Nonlinear optical endoscopy based on a double-clad photonic crystal fiber and a MEMS mirror
Fu, L., Jain, A., Xie, H., Cranfield, C. G., & Gu, M. (2006) · Optics Express · doi:10.1364/oe.14.001027 · Cited by 161
Mostaço-Guidolin, L. B., Rosin, N. L., & Hackett, T. (2017) · International Journal of Molecular Sciences · doi:10.3390/ijms18081772 · Cited by 171
Wu, Y., Leng, Y., Xi, J., & Li, X. D. (2009) · Optics Express · doi:10.1364/oe.17.007907 · Cited by 157
Zhuo, S., Chen, J., Luo, T., Zou, D., & Zhao, J. (2006) · Optics Express · doi:10.1364/oe.14.007810 · Cited by 154
Broadband Coherent Raman Scattering Microscopy
Polli, D., Kumar, V., Valensise, C. M., Marangoni, M., & Cerullo, G. (2018) · Laser & Photonics Review · doi:10.1002/lpor.201800020 · Cited by 151
Georgiadis, M., Müller, R., & Schneider, P. (2016) · Journal of The Royal Society Interface · doi:10.1098/rsif.2016.0088 · Cited by 150
Myers, K. M., Socrate, S., Tzeranis, D. S., & House, M. D. (2009) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2009.02.008 · Cited by 150
Hunt, N. T., Jaye, A. A., & Meech, S. R. (2007) · Physical Chemistry Chemical Physics · doi:10.1039/b616078f · Cited by 147
Quantifying collagen structure in breast biopsies using second-harmonic generation imaging
Ambekar, R., Lau, T.-Y., Walsh, M. J., Bhargava, R., & Toussaint, K. C. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.002021 · Cited by 145
Coherent Anti-Stokes Raman Scattering Microscopy
Cheng, J. (2007) · Applied Spectroscopy · doi:10.1366/000370207781746044 · Cited by 144
The effect of keratoconus on the structural, mechanical, and optical properties of the cornea
Rao, R. A. R., Toussaint, K. C., & Johnson, A. J. W. (2010) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2010.09.014 · Cited by 143
Multiphoton Autofluorescence and Second-Harmonic Generation Imaging of the Ex Vivo Porcine Eye
Teng, S., Tan, H., Peng, J.-L., Lin, H.-H., Kim, K. H., Lo, W., Sun, Y., Lin, W., Lin, S., Jee, S., et al. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-1520 · Cited by 143
Biologically active collagen-based scaffolds: advances in processing and characterization
Yannas, I. V., Tzeranis, D. S., Harley, B. A. C., & So, P. T. C. (2010) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2010.0015 · Cited by 142
Photothermally-induced disordered patterns of corneal collagen revealed by SHG imaging
Matteini, P., Ratto, F., Rossi, F., Cicchi, R., Stringari, C., Kapsokalyvas, D., Pavone, F. S., & Pini, R. (2009) · Optics Express · doi:10.1364/oe.17.004868 · Cited by 140
Endogenous Optical Biomarkers of Ovarian Cancer Evaluated with Multiphoton Microscopy
Kirkpatrick, N. D., BREWER, M. A., & Utzinger, U. (2007) · Cancer Epidemiology Biomarkers & Prevention · doi:10.1158/1055-9965.epi-07-0009 · Cited by 140
Drifka, C. R., Tod, J., Loeffler, A. G., Liu, Y., Thomas, G. J., Eliceiri, K. W., & Kao, W. J. (2015) · Modern Pathology · doi:10.1038/modpathol.2015.97 · Cited by 139
Multicolor two-photon imaging of endogenous fluorophores in living tissues by wavelength mixing
Stringari, C., Abdeladim, L., Malkinson, G., Mahou, P., Solinas, X., Lamarre, I., Brizion, S., Galey, J.-B., Supatto, W., Legouis, R., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-03359-8 · Cited by 147
Probing myosin structural conformation in vivo by second-harmonic generation microscopy
Nucciotti, V., Stringari, C., Sacconi, L., Vanzi, F., Fusi, L., Linari, M., Piazzesi, G., Lombardi, V., & Pavone, F. S. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0914782107 · Cited by 137
Microscopy in 3D: a biologist's toolbox
Fischer, R. S., Wu, Y., Kanchanawong, P., Shroff, H., & Waterman, C. M. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.008 · Cited by 135
Nonlinear optical endomicroscopy for label-free functional histology in vivo
Liang, W., Hall, G., Messerschmidt, B., Li, M.-J., & Li, X. D. (2017) · Light Science & Applications · doi:10.1038/lsa.2017.82 · Cited by 137
Doubly resonant χ (2) nonlinear photonic crystal cavity based on a bound state in the continuum
Minkov, M., Gerace, D., & Fan, S. (2019) · Optica · doi:10.1364/optica.6.001039 · Cited by 134
Dyes for biological second harmonic generation imaging
Reeve, J. E., Anderson, H. L., & Clays, K. (2010) · Physical Chemistry Chemical Physics · doi:10.1039/c003720f · Cited by 132
Nonlinear microscopy: new techniques and applications
Mertz, J. C. (2004) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2004.08.013 · Cited by 137
Optical Clearing for Improved Contrast in Second Harmonic Generation Imaging of Skeletal Muscle
Plotnikov, S. V., Juneja, V., Isaacson, A. B., Mohler, W. A., & Campagnola, P. J. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.066944 · Cited by 131
Self-citation
Metadata
- Authors
- Campagnola, P. J., & Loew, L. M.
- Affiliations
- UConn Health (US)
- Corresponding author
- Loew, Leslie M
- Venue
- Nature Biotechnology
- Published
- 2003-10-31
- Volume
- 21
- Issue
- 11
- Pages
- 1356-1360
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W2077572701
- Cited by
- 1,326
- References
- 29
- Citations by year
- 2026: 37 · 2025: 42 · 2024: 43 · 2023: 50 · 2022: 55 · 2021: 55 · 2020: 67 · 2019: 79 · 2018: 55 · 2017: 67 · 2016: 73 · 2015: 79 · 2014: 61 · 2013: 77 · 2012: 72
- FWCI
- 3.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Biotechnology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r21rr013472-02)
- Office of Naval Research
- National Institute of Biomedical Imaging and Bioengineering (R01EB00196)
- National Center for Research Resources (R21 RR13472)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Cell Image Analysis Techniques
- Keywords
- second harmonic generation, nonlinear optical microscopy, collagen imaging, microtubules, myosin, membrane potential, neuronal electrical activity, in vivo imaging
- MeSH terms
- Action Potentials, Cell Membrane, Cells, Image Enhancement, Membrane Potentials, Proteins, Microscopy, Confocal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review