The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Protein-targeted corona phase molecular recognition
Open accessAbstract
Corona phase molecular recognition (CoPhMoRe) uses a heteropolymer adsorbed onto and templated by a nanoparticle surface to recognize a specific target analyte. This method has not yet been extended to macromolecular analytes, including proteins. Herein we develop a variant of a CoPhMoRe screening procedure of single-walled carbon nanotubes (SWCNT) and use it against a panel of human blood proteins, revealing a specific corona phase that recognizes fibrinogen with high selectivity. In response to fibrinogen binding, SWCNT fluorescence decreases by >80% at saturation. Sequential binding of the three fibrinogen nodules is suggested by selective fluorescence quenching by isolated sub-domains and validated by the quenching kinetics. The fibrinogen recognition also occurs in serum environment, at the clinically relevant fibrinogen concentrations in the human blood. These results open new avenues for synthetic, non-biological antibody analogues that recognize biological macromolecules, and hold great promise for medical and clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous cultures of fused cells secreting antibody of predefined specificity
KÖHLER, G., & MILSTEIN, C. (1975) · Nature · doi:10.1038/256495a0 · Cited by 17,229
Signaling Recognition Events with Fluorescent Sensors and Switches
de Silva, A. P., Gunaratne, H. Q. N., Gunnlaugsson, T., Huxley, A. J. M., McCoy, C. P., Rademacher, J. T., & Rice, T. E. (1997) · Chemical Reviews · doi:10.1021/cr960386p · Cited by 6,995
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Band Gap Fluorescence from Individual Single-Walled Carbon Nanotubes
O'Connell, M. J., Bachilo, S. M., Huffman, C. B., Moore, V. C., Strano, M. S., Haroz, E. H., Rialon, K. L., Boul, P. J., Noon, W. H., Kittrell, C., et al. (2002) · Science · doi:10.1126/science.1072631 · Cited by 3,879
Self-citationStructure-Assigned Optical Spectra of Single-Walled Carbon Nanotubes
Bachilo, S. M., Strano, M. S., Kittrell, C., Hauge, R. H., Smalley, R. E., & Weisman, R. B. (2002) · Science · doi:10.1126/science.1078727 · Cited by 3,078
Self-citationMultiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Wulff, G. (1995) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199518121 · Cited by 2,373
Analysis of membrane and surface protein sequences with the hydrophobic moment plot
Eisenberg, D., Schwarz, E., Komaromy, M., & Wall, R. (1984) · Journal of Molecular Biology · doi:10.1016/0022-2836(84)90309-7 · Cited by 2,284
Directed Self-Assembly of Nanoparticles
Grzelczak, M., Vermant, J., Furst, E. M., & Liz-Marzán, L. M. (2010) · ACS Nano · doi:10.1021/nn100869j · Cited by 2,215
Aptamers: An Emerging Class of Molecules That Rival Antibodies in Diagnostics
Jayasena, S. D. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.9.1628 · Cited by 2,144
Cited by
Carbon-Based Nanomaterials for Biomedical Applications: A Recent Study
Maiti, D., Tong, X., Mou, X., & Yang, K. (2019) · Frontiers in Pharmacology · doi:10.3389/fphar.2018.01401 · Cited by 733
Photoluminescent Nanoparticles for Chemical and Biological Analysis and Imaging
Algar, W. R., Massey, M., Rees, K., Higgins, R., Krause, K. D., Darwish, G. H., Peveler, W. J., Xiao, Z., Tsai, H.-Y., Gupta, R., et al. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01176 · Cited by 356
Wong, M. H., Misra, R. P., Giraldo, J. P., Kwak, S.-Y., Son, Y., Landry, M. P., Swan, J. W., Blankschtein, D., & Strano, M. S. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b04467 · Cited by 338
Self-citationBiosensing with Fluorescent Carbon Nanotubes
Ackermann, J., Metternich, J. T., Herbertz, S., & Kruss, S. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202112372 · Cited by 280
Self-citationMonitoring Plant Health with Near-Infrared Fluorescent H2O2 Nanosensors
Wu, H., Nißler, R., Morris, V., Herrmann, N., Hu, P., Jeon, S.-J., Kruss, S., & Giraldo, J. P. (2020) · Nano Letters · doi:10.1021/acs.nanolett.9b05159 · Cited by 271
Self-citation
Metadata
- Authors
- Bisker, G., Dong, J., Park, H. D., Iverson, N. M., Ahn, J., Nelson, J. T., Landry, M. P., Kruss, S., & Strano, M. S.
- Venue
- Nature Communications
- Published
- 2016-01-08
- Volume
- 7
- Issue
- 1
- Pages
- 10241-10241
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2270889623
- Cited by
- 267
- References
- 57
- FWCI
- 11.74
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Protein-targeted corona phase molecular recognition. https://app.cochat.ai/papers/10.1038/ncomms10241
- The paper
- Bisker, G., Dong, J., Park, H. D., Iverson, N. M., Ahn, J., Nelson, J. T., Landry, M. P., Kruss, S., & Strano, M. S. (2016). Protein-targeted corona phase molecular recognition. Nature Communications. https://doi.org/10.1038/ncomms10241
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.