CoChat

Quantum test of the equivalence principle for atoms in coherent superposition of internal energy states

Open access
Rosi, G., D’Amico, G., Cacciapuoti, L., Sorrentino, F., Prevedelli, M., Zych, M., Brukner, Č., Tino, G. M. · 2017 · Nature Communications

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

Abstract

The Einstein equivalence principle (EEP) has a central role in the understanding of gravity and space–time. In its weak form, or weak equivalence principle (WEP), it directly implies equivalence between inertial and gravitational mass. Verifying this principle in a regime where the relevant properties of the test body must be described by quantum theory has profound implications. Here we report on a novel WEP test for atoms: a Bragg atom interferometer in a gravity gradiometer configuration compares the free fall of rubidium atoms prepared in two hyperfine states and in their coherent superposition. The use of the superposition state allows testing genuine quantum aspects of EEP with no classical analogue, which have remained completely unexplored so far. In addition, we measure the Eötvös ratio of atoms in two hyperfine levels with relative uncertainty in the low 10−9, improving previous results by almost two orders of magnitude.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/ncomms15529

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Schematic of the experiment. Two laser-cooled clouds of 87Rb atoms are launched vertically and prepared in the internal state by velocity-selective Raman pulses. Before the interferometric sequence, a microwave pulse transfers the lower atomic cloud in any superposition of the and states. The Bragg interferometer simultaneously interrogates both atomic clouds, measuring the acceleration of the lower cloud with respect to the upper cloud, which is used as a common reference. The external source masses are positioned to maximize the gravity gradient and optimize the extraction of the differential acceleration from the measurements.
Figure 1 Schematic of the experiment. Two laser-cooled clouds of 87Rb atoms are launched vertically and prepared in the internal state by velocity-selective Raman pulses. Before the interferometric sequence, a microwave pulse transfers the lower atomic cloud in any superposition of the and states. The Bragg interferometer simultaneously interrogates both atomic clouds, measuring the acceleration of the lower cloud with respect to the upper cloud, which is used as a common reference. The external source masses are positioned to maximize the gravity gradient and optimize the extraction of the differential acceleration from the measurements.CC BY · PubMed Central
Figure 2 Experimental data from the Bragg gravity gradiometers. (left) With both atomic samples prepared in the F=1 state (1−1 configuration, black squares), and with the upper sample in F=1 and the lower sample in a coherent superposition of the two hyperfine states (1−s configuration, blue triangles). (right) With both atomic samples prepared in the F=1 state (1−1 configuration, black squares), and with the upper sample in F=1 and the lower sample in F=2 (1−2 configuration, blue triangles). The ellipses best fitting the experimental data are also shown (red lines). The loss of contrast observed on the interferometer can be attributed to the defocusing effect experienced by the atoms when interrogated by the blue-detuned Bragg lasers.
Figure 2 Experimental data from the Bragg gravity gradiometers. (left) With both atomic samples prepared in the F=1 state (1−1 configuration, black squares), and with the upper sample in F=1 and the lower sample in a coherent superposition of the two hyperfine states (1−s configuration, blue triangles). (right) With both atomic samples prepared in the F=1 state (1−1 configuration, black squares), and with the upper sample in F=1 and the lower sample in F=2 (1−2 configuration, blue triangles). The ellipses best fitting the experimental data are also shown (red lines). The loss of contrast observed on the interferometer can be attributed to the defocusing effect experienced by the atoms when interrogated by the blue-detuned Bragg lasers.CC BY · PubMed Central
Figure 3 3D plot of the superposition state data. 3D Lissajous figure obtained by plotting the output signal of the lower F=2 atom interferometer as a function of the output signals of the F=1 interferometers at the upper and lower clouds (black squares). The 3D ellipse best fitting the data (red line) and the orthogonal projections on the three Cartesian planes are also shown.
Figure 3 3D plot of the superposition state data. 3D Lissajous figure obtained by plotting the output signal of the lower F=2 atom interferometer as a function of the output signals of the F=1 interferometers at the upper and lower clouds (black squares). The 3D ellipse best fitting the data (red line) and the orthogonal projections on the three Cartesian planes are also shown.CC BY · PubMed Central
Figure 4 Upper limit on . Parameter A as a function of the RMS noise measured on simulated data points with respect to the best-fitting ellipse. Our ellipses show an RMS noise of 0.0032, corresponding to an upper bound on of 5 × 10−8. The error bars represent the standard error on the RMS: , where N is the number of data points on our ellipses.
Figure 4 Upper limit on . Parameter A as a function of the RMS noise measured on simulated data points with respect to the best-fitting ellipse. Our ellipses show an RMS noise of 0.0032, corresponding to an upper bound on of 5 × 10−8. The error bars represent the standard error on the RMS: , where N is the number of data points on our ellipses.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 37 references

Research works printed but not linked: 2

  1. Tino G. M., Kasevich M. A. (eds) Atom Interferometry SIF and IOS Press (2014).
  2. Zych, M. & Brukner, C. Quantum formulation of the Einstein equivalence principle. Preprint at https://arxiv.org/abs/1502.00971 (2015). · arXiv

Cited by

Items 201–228 of 228

Metadata

Authors
Rosi, G., D’Amico, G., Cacciapuoti, L., Sorrentino, F., Prevedelli, M., Zych, M., Brukner, Č., & Tino, G. M.
Affiliations
  • Istituto Nazionale di Fisica Nucleare, Sezione di Firenze (IT)
  • European Space Agency (FR)
  • Istituto Nazionale di Fisica Nucleare, Sezione di Genova (IT)
  • University of Bologna (IT)
  • The University of Queensland (AU)
  • University of Vienna (AT)
Corresponding author
Tino, G. M.
Venue
Nature Communications
Published
2017-06-01
Volume
8
Issue
1
Pages
15529-15529
ISSN
2041-1723 (ISSN-L)
OpenAlex
W3022985471
Cited by
217
References
37
Citations by year
2026: 8 · 2025: 20 · 2024: 26 · 2023: 25 · 2022: 29 · 2021: 27 · 2020: 31 · 2019: 26 · 2018: 20 · 2017: 5
FWCI
12.26
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Communications (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • Florence Research (University of Florence) (submittedVersion, cc-by)
  • Phaidra (Universität Wien) (submittedVersion, cc-by-nc-nd)
  • RePEc: Research Papers in Economics (submittedVersion)
  • Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • arXiv (Cornell University)
Funders
  • John Templeton Foundation
  • University of Queensland (2016000089)
  • Austrian Science Fund (24621)
  • Ministero dell’Istruzione, dell’Università e della Ricerca (PRIN 2015)
Topics
  • Physical Sciences › Physics and Astronomy › Astronomy and Astrophysics › Relativity and Gravitational Theory
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Mechanics and Applications
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
Keywords
weak equivalence principle, Einstein equivalence principle, gravity gradiometer, rubidium atoms, hyperfine states, coherent superposition, quantum gravity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.