CoChat

Three-dimensional optical holography using a plasmonic metasurface

Open access

The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.

Abstract

Benefitting from the flexibility in engineering their optical response, metamaterials have been used to achieve control over the propagation of light to an unprecedented level, leading to highly unconventional and versatile optical functionalities compared with their natural counterparts. Recently, the emerging field of metasurfaces, which consist of a monolayer of photonic artificial atoms, has offered attractive functionalities for shaping wave fronts of light by introducing an abrupt interfacial phase discontinuity. Here we realize three-dimensional holography by using metasurfaces made of subwavelength metallic nanorods with spatially varying orientations. The phase discontinuity takes place when the helicity of incident circularly polarized light is reversed. As the phase can be continuously controlled in each subwavelength unit cell by the rod orientation, metasurfaces represent a new route towards high-resolution on-axis three-dimensional holograms with a wide field of view. In addition, the undesired effect of multiple diffraction orders usually accompanying holography is eliminated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/ncomms3808

Cites

56 of 56 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Hologram structure and reconstruction procedure. Each nanorod has the role of a pixel of diffractive element, which can generate the required continuous local phase profile with normal incidence of circularly polarized (CP) light, and only opposite handedness CP light are collected. The reconfigured 3D models are designed to appear within the Fresnel range.
Figure 1 Hologram structure and reconstruction procedure. Each nanorod has the role of a pixel of diffractive element, which can generate the required continuous local phase profile with normal incidence of circularly polarized (CP) light, and only opposite handedness CP light are collected. The reconfigured 3D models are designed to appear within the Fresnel range.CC BY · PubMed Central
Figure 2 Experimental investigation of 3D holography by the metasurface. (a) The 3D model for a jet generated in a graphics programme. The size of the jet from left wing to right wing is 330 μm, and from head to tail is 232 μm. The dimension along the z direction is 48.2 μm. (b) Calculated hologram of the jet. Scale bar, 20 μm. (c) Scanning electron microscopy image of a part of the corresponding metasurface. Scale bar, 1 μm. The gold nanorods in the hologram plate are ~150 nm long and ~75 nm wide, and the pixel size s between two neighbouring rods along the x and the y direction is 500 nm. The entire hologram is made of 800 × 800 pixels. (d) Optical set-up for observation of holographic image with tuneable focus positions and rotational angular perspective. (e) Evolution of the appearance of jets for different focusing positions along the z direction with RCP illumination.
Figure 2 Experimental investigation of 3D holography by the metasurface. (a) The 3D model for a jet generated in a graphics programme. The size of the jet from left wing to right wing is 330 μm, and from head to tail is 232 μm. The dimension along the z direction is 48.2 μm. (b) Calculated hologram of the jet. Scale bar, 20 μm. (c) Scanning electron microscopy image of a part of the corresponding metasurface. Scale bar, 1 μm. The gold nanorods in the hologram plate are ~150 nm long and ~75 nm wide, and the pixel size s between two neighbouring rods along the x and the y direction is 500 nm. The entire hologram is made of 800 × 800 pixels. (d) Optical set-up for observation of holographic image with tuneable focus positions and rotational angular perspective. (e) Evolution of the appearance of jets for different focusing positions along the z direction with RCP illumination.CC BY · PubMed Central
Figure 3 Demonstration of the real and the virtual holographic images. (a) Schematic illustration for the appearance of the real and the virtual holographic images of jet on both sides of the metasurface plane. (b) Experimentally obtained images. The real image appears on the transmission side when illuminated and detected by RCP/LCP combination, whereas the virtual image is on the opposite side when both illumination and detection polarizations are reversed. For both real and virtual images, the location where the head of the jet gives a sharp image and is therefore in the imaging focus plane is closer to the metasurface than where the tail looks clear. This verifies that the virtual image and real image are symmetric about the metasurface. The wavelength at which the images were taken is 820 nm.
Figure 3 Demonstration of the real and the virtual holographic images. (a) Schematic illustration for the appearance of the real and the virtual holographic images of jet on both sides of the metasurface plane. (b) Experimentally obtained images. The real image appears on the transmission side when illuminated and detected by RCP/LCP combination, whereas the virtual image is on the opposite side when both illumination and detection polarizations are reversed. For both real and virtual images, the location where the head of the jet gives a sharp image and is therefore in the imaging focus plane is closer to the metasurface than where the tail looks clear. This verifies that the virtual image and real image are symmetric about the metasurface. The wavelength at which the images were taken is 820 nm.CC BY · PubMed Central
Figure 4 Holographic image reconstruction for different wavelengths. Recorded images for wavelengths of (a) λ1=670 nm, (b) λ2=810 nm and (c) λ3=950 nm. (d) Distance of the reconstructed holographic image from the sample surface. The red stars denote the value calculated from angular spectrum method, the square dots represent the experimental measurement and the blue dotted curve is calculated from the simple inverse relationship between the wavelength and z position.
Figure 4 Holographic image reconstruction for different wavelengths. Recorded images for wavelengths of (a) λ1=670 nm, (b) λ2=810 nm and (c) λ3=950 nm. (d) Distance of the reconstructed holographic image from the sample surface. The red stars denote the value calculated from angular spectrum method, the square dots represent the experimental measurement and the blue dotted curve is calculated from the simple inverse relationship between the wavelength and z position.CC BY · PubMed Central
Figure 5 Holography of a 3D helix. (a) Geometry of the helix. (b) The calculated hologram and (c) scanning electron microscopy view of the constituent nanorods pattern. Scale bars, 20 μm and 1 μm in b and c, respectively. (d) On-axis evolution of the total five turn of the helix by tuning the focusing position along the z direction. (e) Numerical calculation of the 2D perspective view by taking into consideration the position-dependent magnification.
Figure 5 Holography of a 3D helix. (a) Geometry of the helix. (b) The calculated hologram and (c) scanning electron microscopy view of the constituent nanorods pattern. Scale bars, 20 μm and 1 μm in b and c, respectively. (d) On-axis evolution of the total five turn of the helix by tuning the focusing position along the z direction. (e) Numerical calculation of the 2D perspective view by taking into consideration the position-dependent magnification.CC BY · PubMed Central
Figure 6 Position-dependent magnification of the optical measurement system. The magnification of our imaging system is obtained from a ray tracing calculation. It shows a nonlinear dependence on the distance of the holographic image to the object plane.
Figure 6 Position-dependent magnification of the optical measurement system. The magnification of our imaging system is obtained from a ray tracing calculation. It shows a nonlinear dependence on the distance of the holographic image to the object plane.CC BY · PubMed Central
Figure 7 Holographic images at tilted observation angles but normal incidence illumination. (a–e) Holographic image observed at different angles with z=1,351 μm. (f–j) The corresponding ray tracing calculations of the 2D perspectives of the holographic images.
Figure 7 Holographic images at tilted observation angles but normal incidence illumination. (a–e) Holographic image observed at different angles with z=1,351 μm. (f–j) The corresponding ray tracing calculations of the 2D perspectives of the holographic images.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 56 references

Cited by

Items 801–900 of 1,000

Metadata

Authors
Huang, L., Chen, X., Mühlenbernd, H., Zhang, H., Chen, S., Bai, B., Tan, Q., Jin, G., Cheah, K.-W., Qiu, C.-W., Li, J., Zentgraf, T., & Zhang, S.
Affiliations
  • University of Birmingham (GB)
  • Paderborn University (DE)
  • Tsinghua University (CN)
  • Hong Kong Baptist University (HK)
  • National University of Singapore (SG)
Corresponding author
  • Zentgraf, Thomas
  • Zhang, Shuang
Venue
Nature Communications
Published
2013-11-15
Volume
4
Issue
1
ISSN
2041-1723 (ISSN-L)
OpenAlex
W2089762744
Cited by
1,456
References
56
Citations by year
2026: 54 · 2025: 114 · 2024: 142 · 2023: 119 · 2022: 118 · 2021: 133 · 2020: 117 · 2019: 138 · 2018: 137 · 2017: 151 · 2016: 112 · 2015: 92 · 2014: 29
FWCI
27.55
Type
journal article
Language
en
Open access
Locations
  • Nature Communications (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • HKBU Institutional Repository (Hong Kong Baptist University) (submittedVersion)
  • Rare & Special e-Zone (The Hong Kong University of Science and Technology) (submittedVersion)
  • National University of Singapore (submittedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
  • University of Birmingham Research Portal (University of Birmingham) (submittedVersion, cc-by)
Funders
  • National Science Foundation
  • European Commission
  • University of Birmingham
  • Deutsche Forschungsgemeinschaft (SPP-1391, GRK 1464)
  • National Natural Science Foundation of China (61161130005, 11004119)
  • China Scholarship Council
  • Engineering and Physical Sciences Research Council (EP/J018473/1)
  • National Key Research and Development Program of China (2013CB328801)
Topics
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Metamaterials and Metasurfaces Applications
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Plasmonic and Surface Plasmon Research
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Antenna and Metasurface Technologies
Keywords
three-dimensional holography, plasmonic metasurfaces, metallic nanorods, circularly polarized light, wavefront shaping, subwavelength unit cells

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.