The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Hydrochromic conjugated polymers for human sweat pore mapping
Open accessAbstract
Hydrochromic materials have been actively investigated in the context of humidity sensing and measuring water contents in organic solvents. Here we report a sensor system that undergoes a brilliant blue-to-red colour transition as well as ‘Turn-On’ fluorescence upon exposure to water. Introduction of a hygroscopic element into a supramolecularly assembled polydiacetylene results in a hydrochromic conjugated polymer that is rapidly responsive (<20 μs), spin-coatable and inkjet-compatible. Importantly, the hydrochromic sensor is found to be suitable for mapping human sweat pores. The exceedingly small quantities (sub-nanolitre) of water secreted from sweat pores are sufficient to promote an instantaneous colorimetric transition of the polymer. As a result, the sensor can be used to construct a precise map of active sweat pores on fingertips. The sensor technology, developed in this study, has the potential of serving as new method for fingerprint analysis and for the clinical diagnosis of malfunctioning sweat pores. Materials capable of colour changes in response to stimuli are useful in sensors and other applications. Here the authors show a conjugated polymer that rapidly responds to the presence of water, and use it as a sensor to map active sweat pores as a means of fingerprint analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NIH Image to ImageJ: 25 years of image analysis
Schneider, C. A., Rasband, W. S., & Eliceiri, K. W. (2012) · Nature Methods · doi:10.1038/nmeth.2089 · Cited by 64,638
Relative Humidity Sensors Based on an Environment-Sensitive Fluorophore in Hydrogel Films
Tellis, J. C., Strulson, C. A., Myers, M. M., & Kneas, K. A. (2011) · Analytical Chemistry · doi:10.1021/ac102616w · Cited by 75
Cited by
Fluorescent and colorimetric sensors for the detection of humidity or water content
Jung, H. S., Verwilst, P., Kim, W. Y., & Kim, J. S. (2016) · Chem. Soc. Rev. · doi:10.1039/c5cs00494b · Cited by 558
Self-citationMethylxanthine Drug Monitoring with Wearable Sweat Sensors
Tai, L., Gao, W., Chao, M., Bariya, M., Ngo, Q. P., Shahpar, Z., Nyein, H. Y. Y., Park, H., Sun, J., Jung, Y., et al. (2018) · Advanced Materials · doi:10.1002/adma.201707442 · Cited by 310
Materials with Tunable Optical Properties for Wearable Epidermal Sensing in Health Monitoring
Han, F., Wang, T., Liu, G., Liu, H., Xie, X., Wei, Z., Li, J., Jiang, C., He, Y., & Xu, F. (2022) · Advanced Materials · doi:10.1002/adma.202109055 · Cited by 250
Metadata
- Authors
- Lee, J., Pyo, M., Lee, S.-H., Kim, J., Ra, M., Kim, W.-Y., Park, B. J., Lee, C. W., & Kim, J.-M.
- Venue
- Nature Communications
- Published
- 2014-04-29
- Volume
- 5
- Issue
- 1
- Pages
- 3736-3736
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2156305378
- Cited by
- 274
- References
- 2
- FWCI
- 11.13
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hydrochromic conjugated polymers for human sweat pore mapping. https://app.cochat.ai/papers/10.1038/ncomms4736
- The paper
- Lee, J., Pyo, M., Lee, S.-H., Kim, J., Ra, M., Kim, W.-Y., Park, B. J., Lee, C. W., & Kim, J.-M. (2014). Hydrochromic conjugated polymers for human sweat pore mapping. Nature Communications. https://doi.org/10.1038/ncomms4736
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.