Interpreting flow cytometry data: a guide for the perplexed
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Correct data transformation can help to diminish this effect [82].”
From Guidelines for the use of flow cytometry and cell sorting in immunological studies (third edition) (2021) · cites this paper as [82]
Citations
Cites
Herzenberg, L. A., Parks, D., Sahaf, B., Perez, O., Roederer, M., & Herzenberg, L. A. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.10.1819 · Cited by 602
Self-citationSpectral compensation for flow cytometry: Visualization artifacts, limitations, and caveats
Roederer, M. (2001) · Cytometry · doi:10.1002/1097-0320(20011101)45:3<194::aid-cyto1163>3.0.co;2-c · Cited by 558
Two-color immunofluorescence using a fluorescence-activated cell sorter.
Loken, M. R., Parks, D. R., & Herzenberg, L. A. (1977) · Journal of Histochemistry & Cytochemistry · doi:10.1177/25.7.330738 · Cited by 193
Self-citationNew approaches to fluorescence compensation and visualization of FACS data
Tung, J. W., Parks, D. R., Moore, W., Herzenberg, L. A., & Herzenberg, L. A. (2004) · Clinical Immunology · doi:10.1016/j.clim.2003.11.016 · Cited by 170
Self-citationIdentification of B-Cell Subsets
Tung, J. W., Parks, D. R., Moore, W. A., Herzenberg, L. A., & Herzenberg, L. A. (2004) · B Cell Protocols · doi:10.1385/1-59259-796-3:037 · Cited by 44
Self-citationGuidelines for the Presentation of Flow Cytometric Data
Roederer, M., Darżynkiewicz, Z., & Parks, D. R. (2004) · Methods in cell biology · doi:10.1016/s0091-679x(04)75010-4 · Cited by 26
Self-citation
Research works printed but not linked: 2
- Parks, D.R., Roederer, M. & Moore, W.A. Cytometry A (in the press).
- Tung, J.W., Parks, D.R., Moore, W.A., Herzenberg, L.A. & Herzenberg, L.A. Methods Mol. Biol. 271, 37–58 (2004).
Cited by
Amir, E.-A. D., Davis, K. L., Tadmor, M. D., Simonds, E. F., Levine, J. H., Bendall, S. C., Shenfeld, D. K., Krishnaswamy, S., Nolan, G. P., & Pe'er, D. (2013) · Nature Biotechnology · doi:10.1038/nbt.2594 · Cited by 1,550
Guidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdis, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 979
Extracting a cellular hierarchy from high-dimensional cytometry data with SPADE
Qiu, P., Simonds, E. F., Bendall, S. C., Gibbs, K. D., Bruggner, R. V., Linderman, M. D., Sachs, K., Nolan, G. P., & Plevritis, S. K. (2011) · Nature Biotechnology · doi:10.1038/nbt.1991 · Cited by 956
“One common but cumbersome step is the selection of subsets of cells in a process called “gating” [3].”
Allan, S. E., Crome, S. Q., Crellin, N. K., Passerini, L., Steiner, T. S., Bacchetta, R., Roncarolo, M. G., & Levings, M. K. (2007) · International Immunology · doi:10.1093/intimm/dxm014 · Cited by 872
“Based on recommendations from Herzenberg ( 18 ) and Roederer (19), gates for FOXP3-positive cells were set based on fluorescence minus one controls.”
Waskow, C., Liu, K., Darrasse-Jèze, G., Guermonprez, P., Ginhoux, F., Merad, M., Shengelia, T., Yao, K., & Nussenzweig, M. (2008) · Nature Immunology · doi:10.1038/ni.1615 · Cited by 665
Two physically, functionally, and developmentally distinct peritoneal macrophage subsets
Ghosn, E. E. B., Cassado, A. A., Govoni, G. R., Fukuhara, T., Yang, Y., Monack, D. M., Bortoluci, K. R., Almeida, S. R., Herzenberg, L. A., & Herzenberg, L. A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0915000107 · Cited by 689
“1; Alexa700labeled anti-IgD (11-26); APCCy7-labeled anti-CD11b (M1/70); Pacific Blue– labeled anti-F4/80 (BM8) or Gr-1 (RB6-8C5) and biotin-labeled anti-CD11c (HL3).”
BackgroundMethodSelf-citationMIFlowCyt: The minimum information about a flow cytometry experiment
Lee, J. A., Spidlen, J., Boyce, K., Cai, J., Crosbie, N., Dalphin, M., Furlong, J., Gasparetto, M., Goldberg, M., Goralczyk, E. M., et al. (2008) · Cytometry Part A · doi:10.1002/cyto.a.20623 · Cited by 533
“Such technological advances, in the absence of reporting standards, also introduce considerable challenges for the producers, reviewers, and consumers of today’s biomedical and immunology literature (3).”
BackgroundSelf-citationGuidelines for the use of flow cytometry and cell sorting in immunological studies (third edition)
Cossarizza, A., Chang, H., Radbruch, A., Abrignani, S., Addo, R., Akdis, M., Andrä, I., Andreata, F., Annunziato, F., Arranz, E., et al. (2021) · European Journal of Immunology · doi:10.1002/eji.202170126 · Cited by 531
Human Endothelial Progenitor Cells
Yoder, M. C. (2012) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a006692 · Cited by 397
“Cite this article as Cold Spring Harb Perspect Med doi: 10.1101/cshperspect.a006692 7 w w w .p er sp ec ti ve si n m ed ic in e. o rg Herzenberg et al. 2006; Parks et al. 2006; Tung et al. 2007).”
BackgroundMethodInfluentialPastrana, E., Cheng, L.-C., & Doetsch, F. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810407106 · Cited by 380
“Data were analyzed with FlowJo data analysis software and displayed using logical (biexponential) scaling (31).”
MethodHoxb5 marks long-term haematopoietic stem cells and reveals a homogenous perivascular niche
Chen, J. Y., Miyanishi, M., Wang, S. K., Yamazaki, S., Sinha, R., Kao, K. S., Seita, J., Sahoo, D., Nakauchi, H., & Weissman, I. L. (2016) · Nature · doi:10.1038/nature16943 · Cited by 345
Transient regulatory T-cells: A state attained by all activated human T-cells
Pillai, V., Ortega, S. B., Wang, C. K., & Karandikar, N. J. (2007) · Clinical Immunology · doi:10.1016/j.clim.2006.10.014 · Cited by 339
“Cut-offs for positive populations were determined by using either fluorescence minus one (FMO) staining for polychromatic flow cytometry, no stimulus background staining or isotype control staining, as appropriate [28; 29].”
MethodYawata, M., Yawata, N., Draghi, M., Partheniou, F., Little, A.-M., & Parham, P. (2008) · Blood · doi:10.1182/blood-2008-03-143727 · Cited by 317
Advances in Human B Cell Phenotypic Profiling
Kaminski, D. A., Wei, C., Qian, Y., Rosenberg, A. F., & Sanz, I. (2012) · Frontiers in Immunology · doi:10.3389/fimmu.2012.00302 · Cited by 272
“Critical considerations include the importance of: (1) excluding non-viable events and debris with a viability-discriminating dye, (2) excluding cell doublets and clumps using the various geometric dimensions of the light-scatter channels (FSC and SSC height versus width), and (3) choosing optimal scaling of plot axes…”
BackgroundMethodThe Fas–FADD death domain complex structure reveals the basis of DISC assembly and disease mutations
Wang, L., Yang, J. K., Kabaleeswaran, V., Rice, A. J., Cruz, A. C., Park, A. Y., Yin, Q., Damko, E., Jang, S. B., Raunser, S., et al. (2010) · Nature Structural & Molecular Biology · doi:10.1038/nsmb.1920 · Cited by 276
“They are displayed in biexponential plots to allow accurate analysis of the FRET signa”
MethodPast, present and future applications of flow cytometry in aquatic microbiology
Wang, Y., Hammes, F., De Roy, K., Verstraete, W., & Boon, N. (2010) · Trends in Biotechnology · doi:10.1016/j.tibtech.2010.04.006 · Cited by 247
Smith, B. R., Ghosn, E. E. B., Rallapalli, H., Prescher, J. A., Larson, T., Herzenberg, L. A., & Gambhir, S. S. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.62 · Cited by 237
Self-citationCameron, P. U., Saleh, S., Sallmann, G., Solomon, A., Wightman, F., Evans, V. A., Boucher, G., Haddad, E. K., Sekaly, R.-P., Harman, A. N., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1002894107 · Cited by 230
Inhibiting myeloid-derived suppressor cell trafficking enhances T cell immunotherapy
Sun, L., Clavijo, P. E., Robbins, Y., Patel, P., Friedman, J., Greene, S., Das, R., Silvin, C., Van Waes, C., Horn, L. A., et al. (2019) · JCI Insight · doi:10.1172/jci.insight.126853 · Cited by 237
“Dead cells were excluded via viability dye staining and a fluorescence-minus-one technique was used to validate specific staining of all antibody combinations (58).”
MethodThe end of gating? An introduction to automated analysis of high dimensional cytometry data
Mair, F., Hartmann, F. J., Mrdjen, D., Tosevski, V., Krieg, C., & Becher, B. (2016) · European Journal of Immunology · doi:10.1002/eji.201545774 · Cited by 234
Diabetes Mellitus Induces Bone Marrow Microangiopathy
Oikawa, A., Siragusa, M., Quaini, F., Mangialardi, G., Katare, R. G., Caporali, A., van Buul, J. D., van Alphen, F. P. J., Graiani, G., Spinetti, G., et al. (2010) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.109.200154 · Cited by 231
Streitz, M., Miloud, T., Kapinsky, M., Reed, M. R., Magari, R., Geissler, E. K., Hutchinson, J. A., Vogt, K., Schlickeiser, S., Kverneland, A. H., et al. (2013) · Transplantation Research · doi:10.1186/2047-1440-2-17 · Cited by 214
“The gated defining negative and positive leukocyte subpopulations for each surface marker were set using color density bi-exponential displays, as also recommended by others [26], except when displaying the cells according to their scatter signals.”
BackgroundMethodAutomatic Classification of Cellular Expression by Nonlinear Stochastic Embedding (ACCENSE)
Shekhar, K., Brodin, P., Davis, M. M., & Chakraborty, A. K. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1321405111 · Cited by 215
Data analysis in flow cytometry: The future just started
Lugli, E., Roederer, M., & Cossarizza, A. (2010) · Cytometry Part A · doi:10.1002/cyto.a.20901 · Cited by 198
“Density information overcome this problem and can be provided graphically by either the use of contour plots or colored dot plots (7,8).”
BackgroundMethodOptimizing a Multicolor Immunophenotyping Assay
Mahnke, Y. D., & Roederer, M. (2007) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2007.05.002 · Cited by 202
“Primary analysis should be performed using plots with a Logicle (biexponential) scale, which permits correct visualization of measurements of high and low intensities and those of negative values [10,13].”
MethodMyeloid-Derived Suppressor Cells Contribute to Staphylococcus aureus Orthopedic Biofilm Infection
Heim, C. E., Vidlak, D., Scherr, T. D., Kozel, J. A., Holzapfel, M., Muirhead, D. E., & Kielian, T. (2014) · The Journal of Immunology · doi:10.4049/jimmunol.1303408 · Cited by 197
“An aliquot of cells was stained with isotype-matched control Abs to assess the degree of nonspecific staining and fluorescence minus one was used to identify gating thresholds (22).”
MethodQian, Y., Wei, C., Eun‐Hyung Lee, F., Campbell, J., Halliley, J., Lee, J. A., Cai, J., Kong, Y. M., Sadat, E., Thomson, E., et al. (2010) · Cytometry Part B: Clinical Cytometry · doi:10.1002/cyto.b.20554 · Cited by 192
Division and differentiation of natural antibody-producing cells in mouse spleen
Yang, Y., Tung, J. W., Ghosn, E. E. B., Herzenberg, L. A., & Herzenberg, L. A. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0700001104 · Cited by 181
Self-citationSuchard, M. A., Wang, Q., Chan, C., Frelinger, J., Cron, A., & West, M. (2010) · Journal of Computational and Graphical Statistics · doi:10.1198/jcgs.2010.10016 · Cited by 179
“Our work is partly motivated by computational challenges in increasingly prevalent biological studies using high-throughput flow cytometry (FCM), generating many large datasets and requiring high-dimensional mixture models with large numbers of mixture components (Herzenberg et al. 2006).”
BackgroundA chromatic explosion: the development and future of multiparameter flow cytometry
Chattopadhyay, P. K., Hogerkorp, C., & Roederer, M. (2008) · Immunology · doi:10.1111/j.1365-2567.2008.02989.x · Cited by 165
Abeles, (. D., McPhail, M. J., Sowter, D., Antoniades, C. G., Vergis, N., Vijay, G. K. M., Xystrakis, E., Khamri, W., Shawcross, D. L., Ma, Y., et al. (2012) · Cytometry Part A · doi:10.1002/cyto.a.22104 · Cited by 164
“All fluorescent parameters were displayed using biexponential scaling (48,49).”
BackgroundMethodMund, J. A., Estes, M. L., Yoder, M. C., Ingram, D. A., & Case, J. (2012) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.111.244210 · Cited by 164
“Using traditional logarithmic dot plots can disguise significant cell populations with low expression and lead to misreporting of actual event frequencies, but reanalysis of these cell populations with contour plot displays has exposed considerable differences in both the identification and frequency analysis of rare…”
BackgroundLaw, S. C., Street, S., Yu, C.-H. A., Capini, C., Ramnoruth, S., Nel, H. J., van Gorp, E., Hyde, C., Lau, K., Pahau, H., et al. (2012) · Arthritis Research & Therapy · doi:10.1186/ar3848 · Cited by 154
“Fluorescence minus one staining demonstrates the gating strategy to determine the threshold for positive staining, as described elsewhere [20] (Figure 6C).”
BackgroundZheng, Y., de la Cruz, C. C., Sayles, L. C., Alleyne-Chin, C., Vaka, D., Knaak, T. D., Bigos, M., Xu, Y., Hoang, C. D., Shrager, J. B., et al. (2013) · Cancer Cell · doi:10.1016/j.ccr.2013.05.021 · Cited by 154
“Gates were es- 72 Cancer Cell 24, 59–74, July 8, 2013 ª2013 Elsevier Inc. tablished by comparing FACS plot against fluorescence minus one (FMO) sample with a cutoff of 0.5% positive cells in the FMO sample as previously described (Herzenberg et al., 2006).”
InfluentialPurification of Specific Cell Population by Fluorescence Activated Cell Sorting (FACS)
Basu, S., Campbell, H. M., Dittel, B. N., & Ray, A. (2010) · Journal of Visualized Experiments · doi:10.3791/1546 · Cited by 155
Heim, C. E., Vidlak, D., Scherr, T. D., Hartman, C. W., Garvin, K. L., & Kielian, T. (2015) · The Journal of Immunology · doi:10.4049/jimmunol.1402689 · Cited by 148
“Controls included cells stained with isotype control Abs to assess the degree of nonspecific staining, as well as fluorescence minus one to identify gating thresholds (30).”
BackgroundMethods for discovery and characterization of cell subsets in high dimensional mass cytometry data
Diggins, K. E., Ferrell, P. B., & Irish, J. M. (2015) · Methods · doi:10.1016/j.ymeth.2015.05.008 · Cited by 141
Particle Display: A Quantitative Screening Method for Generating High‐Affinity Aptamers
Wang, J., Gong, Q., Maheshwari, N., Eisenstein, M. S., Arcila, M. L., Kosik, K. S., & Soh, H. T. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201309334 · Cited by 147
Hypoxia compromises the mitochondrial metabolism of Alzheimer’s disease microglia via HIF1
March-Diaz, R., Lara-Ureña, N., Romero-Molina, C., Heras-Garvin, A., Ortega-de San Luis, C., Alvarez-Vergara, M. I., Sanchez-Garcia, M. A., Sanchez-Mejias, E., Davila, J. C., Rosales-Nieves, A. E., et al. (2021) · Nature Aging · doi:10.1038/s43587-021-00054-2 · Cited by 125
Ramon, S., Baker, S. F., Sahler, J., Kim, N., Feldsott, E. A., Serhan, C. N., Martínez‐Sobrido, L., Topham, D. J., & Phipps, R. P. (2014) · The Journal of Immunology · doi:10.4049/jimmunol.1302795 · Cited by 129
“Fluorescence minus one controls were included in each staining protocol and were used to set specific gates (22, 26, 27).”
MethodDiehl, S. A., Schmidlin, H., Nagasawa, M., Blom, B., & Spits, H. (2012) · Immunology & Cell Biology · doi:10.1038/icb.2012.17 · Cited by 114
Schonewille, E., Singh, A., Göbel, T., Gerner, W., Saalmüller, A., & Heß, M. (2007) · Veterinary Immunology and Immunopathology · doi:10.1016/j.vetimm.2007.09.017 · Cited by 109
Impact of age on T cell signaling: A general defect or specific alterations?
Larbi, A., Pawelec, G., Wong, S. C., Goldeck, D., Tai, J. J.-Y., & Fulop, T. (2011) · Ageing Research Reviews · doi:10.1016/j.arr.2010.09.008 · Cited by 108
Zhang, W., Li, I., Reticker-Flynn, N. E., Good, Z., Chang, S., Samusik, N., Saumyaa, S., Li, Y., Zhou, X., Liang, R., et al. (2022) · Nature Methods · doi:10.1038/s41592-022-01498-z · Cited by 108
CD11b expression distinguishes sequential stages of peritoneal B-1 development
Ghosn, E. E. B., Yang, Y., Tung, J., Herzenberg, L. A., & Herzenberg, L. A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0712350105 · Cited by 105
“By applying modern high-dimensional (Hi-D) FACS data collection and analysis methods (16, 17), we clearly resolve a CD11b PerC B-1 subset from a CD11b PerC B-1 subset.”
MethodSelf-citationGraphical Models via Univariate Exponential Family Distributions.
Yang, E., Ravikumar, P., Allen, G. I., & Liu, Z. (2015) · PubMed · Cited by 180
Local increase in thymic stromal lymphopoietin induces systemic alterations in B cell development
Astrakhan, A., Omori, M., Nguyen, T., Becker-Herman, S., Iseki, M., Aye, T., Hudkins, K. L., Dooley, J., Farr, A. G., Alpers, C. E., et al. (2007) · Nature Immunology · doi:10.1038/ni1452 · Cited by 107
Optimizing transformations for automated, high throughput analysis of flow cytometry data
Finak, G., Perez, J.-M., Weng, A., & Gottardo, R. (2010) · BMC Bioinformatics · doi:10.1186/1471-2105-11-546 · Cited by 99
“The underpinning principle is to choose a transformation that facilitates cell population gating, visualization, and intersample comparison, by obtaining a representation wherein cell populations are well resolved across the full range of the data [6,12,15-17].”
BackgroundGuidelines on the use of multicolour flow cytometry in the diagnosis of haematological neoplasms
Johansson, U., Bloxham, D. M., Couzens, S., Jesson, J., Morilla, R. M., Erber, W. N., & Macey, M. G. (2014) · British Journal of Haematology · doi:10.1111/bjh.12789 · Cited by 110
“It is recommended that logicle displays always be used, as these allow all populations to be visualized without events clustering on the plot axis (Herzenberg et al, 2006; Parks et al, 2006) Most current software have a logicle or bi-exponential display option.”
BackgroundMethodBrower, K. K., Carswell-Crumpton, C., Klemm, S. L., Cruz, B. N., Kim, G., Calhoun, S. G. K., Nichols, L. A., & Fordyce, P. M. (2020) · Lab on a Chip · doi:10.1039/d0lc00261e · Cited by 108
Distinct Subsets of FoxP3+ Regulatory T Cells Participate in the Control of Immune Responses
Stephens, G. L., Andersson, J., & Shevach, E. M. (2007) · The Journal of Immunology · doi:10.4049/jimmunol.178.11.6901 · Cited by 97
“In some cases, visualization of negative data acquired during 8–10 color analyses were facilitated by performing postacquisition biexponential transformations as previously described (24) using FlowJo software.”
MethodBraun, J., Hack, A., Weis-Klemm, M., Conrad, S., Treml, S., Köhler, K., Walliser, U., Skutella, T., & Aicher, W. K. (2010) · American Journal of Veterinary Research · doi:10.2460/ajvr.71.10.1228 · Cited by 99
“16 The difference between the geometric mean value the fluorescence intensities of unstained samples and that of stained samples was calculated as the MFI shift. qRT-PCR assay —”
MethodEspéli, M., Mancini, S. J. C., Breton, C. S., Poirier, F., & Schiff, C. (2009) · Blood · doi:10.1182/blood-2009-01-198465 · Cited by 110
Increased Expression of Regulatory T Cells and Down-Regulatory Molecules in Lepromatous Leprosy
Palermo, M. D. L., Pagliari, C., Trindade, M. Â. B., Yamashitafuji, T. M. T., Duarte, A. J. S., Cacere, C. R., & Benard, G. (2012) · American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2012.12-0088 · Cited by 97
“populations analyzed was carried out in each experiment using unstained cells and the fluorescence minus one protocol.(13) The results were expressed as the percentage of”
MethodAutoimmune Manifestations in the 3xTg-AD Model of Alzheimer's Disease
Marchese, M., Cowan, D., Head, E., Ma, D., Karimi, K., Ashthorpe, V., Kapadia, M., Zhao, H., Davis, P., & Sakic, B. (2014) · Journal of Alzheimer's Disease · doi:10.3233/jad-131490 · Cited by 94
Koguchi, Y., Thauland, T. J., Slifka, M. K., & Parker, D. C. (2007) · Blood · doi:10.1182/blood-2007-03-081299 · Cited by 106
“Data obtained by FACSCalibur and LSRII are presented in logarithmic and “logicle” displays, respectively.(30) Data were analyzed with FlowJo software (Tree Star, Inc.”
MethodPilz, G.-A., Ulrich, C., Ruh, M., Abele, H., Schäfer, R., Kluba, T., Bühring, H., Rolauffs, B., & Aicher, W. K. (2010) · Stem Cells and Development · doi:10.1089/scd.2010.0308 · Cited by 99
“2.2, Treestar Inc., Ashland, OR) following recently updated guidelines [37].”
InfluentialBasic Multicolor Flow Cytometry
Maciorowski, Z., Chattopadhyay, P. K., & Jain, P. (2017) · Current Protocols in Immunology · doi:10.1002/cpim.26 · Cited by 84
Guerra, E. S., Lee, C. K., Specht, C. A., Yadav, B., Huang, H., Akalin, A., Huh, J. R., Mueller, C., & Levitz, S. M. (2017) · PLOS Pathogens · doi:10.1371/journal.ppat.1006175 · Cited by 88
“Gating was established using FMO controls containing isotype control mAb conjugated with the fluorophore corresponding to the missing antibody as described [68].”
MethodNotch activity synergizes with B-cell–receptor and CD40 signaling to enhance B-cell activation
Thomas, M., Calamito, M., Srivastava, B., Maillard, I., Pear, W. S., & Allman, D. (2007) · Blood · doi:10.1182/blood-2006-09-046698 · Cited by 86
“5, anti-IgD (11-26) was conjugated to biotin and revealed with streptavidin–PE–Texas red, and NP-conjugated APC was kindly provided by Dr Michael Cancro (University of Pennsylvania).”
MethodEpigenetic immune cell counting in human blood samples for immunodiagnostics
Baron, U., Werner, J., Schildknecht, K., Schulze, J., Mulu, A., Liebert, U.-G., Sack, U., Speckmann, C., Gossen, M., Wong, R. J., et al. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aan3508 · Cited by 88
Jahan-Tigh, R. R., Ryan, C., Obermoser, G., & Schwarzenberger, K. (2012) · Journal of Investigative Dermatology · doi:10.1038/jid.2012.282 · Cited by 91
An updated guide for the perplexed: cytometry in the high-dimensional era
Liechti, T., Weber, L. M., Ashhurst, T. M., Stanley, N., Prlic, M., Gassen, S. V., & Mair, F. (2021) · Nature Immunology · doi:10.1038/s41590-021-01006-z · Cited by 95
Generation of peripheral B cells occurs via two spatially and temporally distinct pathways
Lindsley, R. C., Thomas, M., Srivastava, B., & Allman, D. (2006) · Blood · doi:10.1182/blood-2006-04-018085 · Cited by 87
Sorting Out the FACS: A Devil in the Details
Hines, W. C., Su, Y., Kuhn, I., Polyak, K., & Bissell, M. J. (2014) · Cell Reports · doi:10.1016/j.celrep.2014.02.021 · Cited by 85
Do Pluripotent Stem Cells Exist in Adult Mice as Very Small Embryonic Stem Cells?
Miyanishi, M., Mori, Y., Seita, J., Chen, J. Y., Karten, S., Chan, C. K. F., Nakauchi, H., & Weissman, I. L. (2013) · Stem Cell Reports · doi:10.1016/j.stemcr.2013.07.001 · Cited by 89
“To minimize the risk of missing candidate cells, SCA-1 cells (including SCA-1) beyond the threshold defined by the fluorescence minus one (FMO) method (Herzenberg et al., 2006) were included, and only the obvious Lin cells were excluded from the Lin fraction (which included Lin cells).”
Miranda, M. C. G., de Oliveira, R. P., Torres, L., Aguiar, S. L. F., Pinheiro-Rosa, N., Lemos, L., Guimarães, M. A. F., Reis, D. S., Silveira, T. L., Ferreira, E. F., et al. (2019) · Journal of Leukocyte Biology · doi:10.1002/jlb.3hi0119-024rr · Cited by 85
Baughman, E. J., Mendoza, J. P., Ortega, S. B., Ayers, C. L., Greenberg, B. M., Frohman, E. M., & Karandikar, N. J. (2011) · Journal of Autoimmunity · doi:10.1016/j.jaut.2010.12.003 · Cited by 76
“Cut-offs for positive populations were determined by using either fluorescence minus one (FMO) staining for polychromatic flow cytometry, no stimulus background CFSE staining, or isotype control staining, as appropriate [32].”
MethodTaylor, J. J., Krawczyk, C. M., Mohrs, M., & Pearce, E. J. (2009) · Journal of Clinical Investigation · doi:10.1172/jci36534 · Cited by 90
Mencia-Trinchant, N., Hu, Y., Alas, M. A., Ali, F., Wouters, B. J., Lee, S. M., Ritchie, E. K., Desai, P. M., Guzmán, M. L., Roboz, G. J., et al. (2017) · Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2017.03.005 · Cited by 82
Estes, M. L., Mund, J. A., Mead, L. E., Prater, D. N., Cai, S., Wang, H., Pollok, K. E., Murphy, M. P., An, C., Srour, E. F., et al. (2010) · Cytometry Part A · doi:10.1002/cyto.a.20921 · Cited by 84
“cess of data acquisition and interpretation (1,2).”
MethodCassado, A. D. A., de Albuquerque, J. A. T., Sardinha, L. R., Buzzo, C. D. L., Faustino, L., Nascimento, R., Ghosn, E., Lima, M. R. D., Álvarez, J. M., & Bortoluci, K. R. (2011) · PLoS ONE · doi:10.1371/journal.pone.0022141 · Cited by 89
“Gray lines represent FMO [23,25], the black lines show F4/ 80MHCII cells from zymosan- (hairline) or T.”
BackgroundMethodInfluentialAhlén, M. T., Husebekk, A., Killie, M. K., Skogen, B. R., & Stuge, T. B. (2009) · Blood · doi:10.1182/blood-2008-09-178475 · Cited by 75
Fc Receptor-Like 3 Protein Expressed on IL-2 Nonresponsive Subset of Human Regulatory T Cells
Nagata, S., Ise, T., & Pastan, I. H. (2009) · The Journal of Immunology · doi:10.4049/jimmunol.0802230 · Cited by 74
“To determine positive and negative events for each marker, all reagents except for the one of interest (fluorescence minus one, or “FMO” controls) were used to identify expressing cells in the fully stained sample (35).”
MethodOn Graphical Models via Univariate Exponential Family DistributionsPreprint
Yang, E., Ravikumar, P., Allen, G. I., & Liu, Z. (2013) · arXiv (Cornell University) · doi:10.48550/arxiv.1301.4183 · Cited by 68
“Thus to model such data, these measurements are typically normalized to be approximately Gaussian using a log transform after shifting the data to be non-negative (Herzenberg et al. 2006).”
MethodMcNeil, L. K., Price, L. S., Britten, C. M., Jaimes, M. C., Maecker, H. T., Odunsi, K. O., Matsuzaki, J., Staats, J. S., Thorpe, J., Yuan, J. D., et al. (2013) · Cytometry Part A · doi:10.1002/cyto.a.22319 · Cited by 67
“There are several tutorials and papers that help to understand biexponential transformation of flow cytometry data (23,24); FlowJo Transformation Overview).”
BackgroundPintarič, M., Gerner, W., & Saalmüller, A. (2007) · Veterinary Immunology and Immunopathology · doi:10.1016/j.vetimm.2007.08.009 · Cited by 67
Rosa, C. L., Krishnan, A., Longmate, J., Martinez, J., Manchanda, P., Lacey, S. F., Limaye, A. P., & Diamond, D. J. (2007) · The Journal of Infectious Diseases · doi:10.1086/523652 · Cited by 67
“Biexponential analysis and 5% quantile contour plots for data display [19] were done using BD FACSDiva (version 5.”
Separating Stem Cells by Flow Cytometry: Reducing Variability for Solid Tissues
Alexander, C. M., Puchalski, J. R., Klos, K. S., Badders, N. M., Ailles, L., Kim, C. F., Dirks, P. B., & Smalley, M. J. (2009) · Cell stem cell · doi:10.1016/j.stem.2009.11.008 · Cited by 70
“Detailed criteria and techniques have been discussed by Roederer and Herzenberg, especially with respect to setting standards for hematopoietic cell analysis (Herzenberg et al., 2006; Moore and Roederer, 2009; Perfetto et al., 2006; Perfetto etal., 2004;Roederer, 2002a, 2008).”
MethodDeconstructing stem cell population heterogeneity: Single-cell analysis and modeling approaches
Wu, J., & Tzanakakis, E. S. (2013) · Biotechnology Advances · doi:10.1016/j.biotechadv.2013.09.001 · Cited by 71
“And although flow cytometry systems with up to 16 channels are available for resolving fluorescence for sample analysis and sorting, compensation problems should be carefully addressed (Herzenberg et al., 2006).”
Human blood dendritic cell subsets exhibit discriminative pattern recognition receptor profiles
Lundberg, K., Rydnert, F., Greiff, L., & Lindstedt, M. (2014) · Immunology · doi:10.1111/imm.12252 · Cited by 71
Moon, J.-H., Kim, G., Lee, S., & Park, S. (2013) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2013.08.005 · Cited by 62
Tighe, R. M., Redente, E. F., Yu, Y.-R. A., Herold, S., Sperling, A. I., Curtis, J. L., Duggan, R., Swaminathan, S., Nakano, H., Zacharias, W. J., et al. (2019) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/rcmb.2019-0191st · Cited by 74
“Compensation and Gating Proper compensation and gating are necessary to correctly visualize and interpret flow cytometry data (27).”
BackgroundAdvances in complex multiparameter flow cytometry technology: Applications in stem cell research
Preffer, F. I., & Dombkowski, D. (2009) · Cytometry Part B Clinical Cytometry · doi:10.1002/cyto.b.20480 · Cited by 68
“tration, potential dye–dye interactions, fluorescence compensation, and staining controls (15,17,29).”
Aybar, L. T., McGregor, J. G., Hogan, S. L., Hu, Y., Mendoza, C. E., Brant, E. J., Poulton, C. J., Henderson, C. D., Falk, R. J., & Bunch, D. O. (2015) · Clinical & Experimental Immunology · doi:10.1111/cei.12483 · Cited by 65
Broady, R., Yu, J., & Levings, M. K. (2009) · Blood · doi:10.1182/blood-2009-04-214437 · Cited by 60
Sanz, E., Muñoz-A., N., Monserrat, J., Van-Den-Rym, A., Escoll, P., Ranz, I., Álvarez-Mon, M., & de-la-Hera, A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0907942107 · Cited by 55
Flow Cytometry in Veterinary Oncology
Reggeti, F., & Bienzle, D. (2010) · Veterinary Pathology · doi:10.1177/0300985810379435 · Cited by 60
“The limitations of linear and logarithmic data presentation and analysis have recently been explored, and novel approaches are now often incorporating biexponential (‘‘logicle’’) data display to provide more detail on properties of cells in dim regions of logarithmic scales.(35) Owing to the numerous permutations of d…”
MethodTumor Presence Induces Global Immune Changes and Enhances Nanoparticle Clearance
Kai, M. P., Brighton, H. E., Fromen, C. A., Shen, T. W., Luft, J. C., Luft, Y. E., Keeler, A. W., Robbins, G. R., Ting, J. P. ‐., Zamboni, W. C., et al. (2015) · ACS Nano · doi:10.1021/acsnano.5b05999 · Cited by 60
Publishing flow cytometry data
Alvarez, D. F., Helm, K. M., DeGregori, J. V., Roederer, M., & Majka, S. M. (2009) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00313.2009 · Cited by 59
“Using such a separation approach, cellular patterns can be identified by assessing, in individual cells within a population, protein expression using fluorescently labeled antibodies and other fluorescent probes (1, 4).”
BackgroundLarbi, A., Zelba, H., Goldeck, D., & Pawelec, G. (2009) · Journal of Leukocyte Biology · doi:10.1189/jlb.0509304 · Cited by 58
“Ashland, OR, US) following guidelines updated recently [15].”
BackgroundA Functional γδTCR/CD3 Complex Distinct from γδT Cells Is Expressed by Human Eosinophils
Legrand, F., Driss, V., Woerly, G., Loiseau, S., Hermann, E., Fournié, J., Héliot, L., Mattot, V., Soncin, F., Gougeon, M., et al. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005926 · Cited by 67
“Multiple staining experiments are represented as color density plots [63] with linear scales used for both forward (FSC) and side scatter (SSC) and logarithmic scales used for fluorescence parameters (Log density: 50%).”
Variation in mate preference across a house mouse hybrid zone
Ganem, G., LITEL, C., & Lenormand, T. (2008) · Heredity · doi:10.1038/hdy.2008.20 · Cited by 59
Vidlak, D., & Kielian, T. (2016) · Infection and Immunity · doi:10.1128/iai.00117-16 · Cited by 57
“Controls included cells stained with isotype control antibodies to assess the degree of nonspecific staining, as well as fluorescence minus one to identify gating thresholds (43).”
BackgroundAntigen-specific antibody responses in B-1a and their relationship to natural immunity
Yang, Y., Ghosn, E., Cole, L. E., Obukhanych, T. V., Sadate-Ngatchou, P. I., Vogel, S. N., Herzenberg, L. A., & Herzenberg, L. A. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1121631109 · Cited by 56
“The boundary for FtL binding is determined from thefluorescence-minus-one (FMO) (40) staining control inwhichfluorochrome-labeled FtLwas omitted from the stainset (RightmostTop).”
BackgroundSelf-citationUlrich, C., Abruzzese, T., Maerz, J. K., Ruh, M., Amend, B., Benz, K., Rolauffs, B., Abele, H., Hart, M. L., & Aicher, W. K. (2015) · Stem Cells and Development · doi:10.1089/scd.2014.0465 · Cited by 58
Roarty, K. P., Shore, A. N., Creighton, C. J., & Rosen, J. M. (2015) · The Journal of Cell Biology · doi:10.1083/jcb.201408058 · Cited by 59
“…compensated data that has been display transformed, where the scale is compressed in the lower range of the axes, leading to more accurate visual representation of fluorescence units in the lower range of the scale (http://www.flowjo .com/v76/en/displaytransformwhy.html; Herzenberg et al., 2006).”
Regulatory Role of Lymphoid Chemokine CCL19 and CCL21 in the Control of Allergic Rhinitis
Takamura, K., Fukuyama, S., Nagatake, T., Kim, D., Kawamura, A., Kawauchi, H., & Kiyono, H. (2007) · The Journal of Immunology · doi:10.4049/jimmunol.179.9.5897 · Cited by 62
“Compensation was carefully performed in each tissue in accordance with the published instructions (31, 32).”
MethodDalgaard, T. S., Norup, L. R., Pedersen, A. R., Handberg, K. J., Jørgensen, P. H., & Juul‐Madsen, H. R. (2010) · Vaccine · doi:10.1016/j.vaccine.2010.04.044 · Cited by 55
Large-scale progenitor cell expansion for multiple donors in a monitored hollow fibre bioreactor
Lambrechts, T., Papantoniou, I., Rice, B., Schrooten, J., Luyten, F. P., & Aerts, J. (2016) · Cytotherapy · doi:10.1016/j.jcyt.2016.05.013 · Cited by 55
Metadata
- Authors
- Herzenberg, L. A., Tung, J., Moore, W. A., Herzenberg, L. A., & Parks, D. R.
- Affiliations
- Stanford Medicine (US)
- Venue
- Nature Immunology
- Published
- 2006-07
- Volume
- 7
- Issue
- 7
- Pages
- 681-685
- ISSN
- 1529-2908 (ISSN-L)
- 1529-2916
- OpenAlex
- W2153283070
- Cited by
- 464
- References
- 6
- Citations by year
- 2026: 11 · 2025: 13 · 2024: 17 · 2023: 14 · 2022: 18 · 2021: 20 · 2020: 19 · 2019: 23 · 2018: 23 · 2017: 21 · 2016: 38 · 2015: 38 · 2014: 33 · 2013: 30 · 2012: 29
- FWCI
- 12.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Immunology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Cell Image Analysis Techniques
- Life Sciences › Immunology and Microbiology › Immunology › T-cell and B-cell Immunology
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Keywords
- flow cytometry data analysis, data interpretation, flow cytometry instrumentation, data visualization, immunology research
- MeSH terms
- Algorithms, Computer Graphics, Data Display, Equipment Design, Flow Cytometry, Fluorometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.