The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
MRI-detectable pH nanosensors incorporated into hydrogels for in vivo sensing of transplanted-cell viability
Open accessAbstract
Biocompatible nanomaterials and hydrogels have become an important tool for improving cell-based therapies by promoting cell survival and protecting cell transplants from immune rejection. Although their potential benefit has been widely evaluated, it is currently not possible to determine, in vivo, if and how long cells remain viable following their administration without the use of a reporter gene. We here report a pH nanosensor-based magnetic resonance imaging (MRI) technique that can monitor cell death in vivo non-invasively. We demonstrate that specific MRI parameters that change upon cell death of microencapsulated hepatocytes are associated with the measured bioluminescence imaging (BLI) radiance. Moreover, the readout from this pH-sensitive nanosensor can be directly co-registered with high-resolution anatomical images. All the components of these nanosensors are clinical-grade and hence this approach should be a translatable and universal modification of hydrogels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vivo MRI cell tracking: clinical studies
Bulte, J. W. M. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.3107 · Cited by 430
Self-citation
Cited by
Advances in engineering hydrogels
Zhang, Y. S., & Khademhosseini, A. (2017) · Science · doi:10.1126/science.aaf3627 · Cited by 2,908
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Xu, L., Gutbrod, S. R., Bonifas, A. P., Su, Y., Sulkin, M. S., Lu, N., Chung, H.-J., Jang, K.-I., Liu, Z., Ying, M., et al. (2014) · Nature Communications · doi:10.1038/ncomms4329 · Cited by 634
Mi, P., Kokuryo, D., Cabral, H., Wu, H., Terada, Y., Saga, T., Aoki, I., Nishiyama, N., & Kataoka, K. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.72 · Cited by 512
Engineering of inorganic nanoparticles as magnetic resonance imaging contrast agents
Ni, D., Bu, W., Ehlerding, E. B., Cai, W., & Shi, J. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00316a · Cited by 484
Metadata
- Authors
- Chan, K. W. Y., Liu, G., Song, X., Kim, H., Yu, T., Arifin, D. R., Gilad, A. A., Hanes, J., Walczak, P., van Zijl, P. C. M., Bulte, J. W. M., & McMahon, M. T.
- Venue
- Nature Materials
- Published
- 2013-01-27
- Volume
- 12
- Issue
- 3
- Pages
- 268-275
- ISSN
- 1476-1122 (ISSN-L)
- 1476-4660
- OpenAlex
- W2131489888
- Cited by
- 205
- References
- 1
- FWCI
- 11.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MRI-detectable pH nanosensors incorporated into hydrogels for in vivo sensing of transplanted-cell viability. https://app.cochat.ai/papers/10.1038/nmat3525
- The paper
- Chan, K. W. Y., Liu, G., Song, X., Kim, H., Yu, T., Arifin, D. R., Gilad, A. A., Hanes, J., Walczak, P., van Zijl, P. C. M., Bulte, J. W. M., & McMahon, M. T. (2013). MRI-detectable pH nanosensors incorporated into hydrogels for in vivo sensing of transplanted-cell viability. Nature Materials. https://doi.org/10.1038/nmat3525
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.