Simultaneous transcranial magnetic stimulation and single-neuron recording in alert non-human primates
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Transcranial magnetic stimulation (TMS) is a widely used, noninvasive method for stimulating nervous tissue, yet its mechanisms of effect are poorly understood. Here we report new methods for studying the influence of TMS on single neurons in the brain of alert non-human primates. We designed a TMS coil that focuses its effect near the tip of a recording electrode and recording electronics that enable direct acquisition of neuronal signals at the site of peak stimulus strength minimally perturbed by stimulation artifact in awake monkeys (Macaca mulatta). We recorded action potentials within ∼1 ms after 0.4-ms TMS pulses and observed changes in activity that differed significantly for active stimulation as compared with sham stimulation. This methodology is compatible with standard equipment in primate laboratories, allowing easy implementation. Application of these tools will facilitate the refinement of next generation TMS devices, experiments and treatment protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes
Buzsáki, G., Anastassiou, C. A., & Koch, C. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3241 · Cited by 4,225
Depression of motor cortex excitability by low-frequency transcranial magnetic stimulation
Chen, R., Classen, J., Gerloff, C., Celnik, P., Wassermann, E. M., Hallett, M., & Cohen, L. G. (1997) · Neurology · doi:10.1212/wnl.48.5.1398 · Cited by 2,128
Physiology of repetitive transcranial magnetic stimulation of the human brain
Hoogendam, J. M., Ramakers, G. M. J., & Di Lazzaro, V. (2010) · Brain Stimulation · doi:10.1016/j.brs.2009.10.005 · Cited by 669
Deng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/016007 · Cited by 216
Self-citationCoil design for real and sham transcranial magnetic stimulation
Ruohonen, J., Ollikainen, M., Nikouline, V., Virtanen, J., & Ilmoniemi, R. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.821731 · Cited by 60
Cited by
Rossini, P. M., Burke, D., Chen, R., Cohen, L. G., Daskalakis, Z., Di Iorio, R., Di Lazzaro, V., Ferreri, F., Fitzgerald, P. B., George, M. S., et al. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.02.001 · Cited by 2,753
Rossi, S., Antal, A., Bestmann, S., Bikson, M., Brewer, C., Brockmöller, J., Carpenter, L. L., Cincotta, M., Chen, R., Daskalakis, J. D., et al. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.10.003 · Cited by 1,573
Self-citationZiemann, U., Reis, J., Schwenkreis, P., Rosanova, M., Strafella, A., Badawy, R., & Müller-Dahlhaus, F. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.08.028 · Cited by 681
Siebner, H. R., Funke, K., Aberra, A. S., Antal, A., Bestmann, S., Chen, R., Classen, J., Davare, M., Di Lazzaro, V., Fox, P. T., et al. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2022.04.022 · Cited by 566
Self-citationClinical utility and prospective of TMS–EEG
Tremblay, S., Rogasch, N. C., Premoli, I., Blumberger, D. M., Casarotto, S., Chen, R., Di Lazzaro, V., Farzan, F., Ferrarelli, F., Fitzgerald, P. B., et al. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.01.001 · Cited by 472
Zrenner, C., Desideri, D., Belardinelli, P., & Ziemann, U. (2018) · Brain Stimulation · doi:10.1016/j.brs.2017.11.016 · Cited by 451
Plasticity induced by non-invasive transcranial brain stimulation: a position paper
Huang, Y.-Z., Lu, M.-K., Antal, A., Classen, J., Nitsche, M., Ziemann, U., Ridding, M., Hamada, M., Ugawa, Y., Jaberzadeh, S., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.09.007 · Cited by 401
“A further step ahead is the recent demonstration of successful recording of single cell responses to TMS in the motor cortex of an awake monkey (Mueller et al., 2014).”
Aberra, A. S., Wang, B., Grill, W. M., & Peterchev, A. V. (2020) · Brain Stimulation · doi:10.1016/j.brs.2019.10.002 · Cited by 323
Self-citationInferring Causality from Noninvasive Brain Stimulation in Cognitive Neuroscience
Bergmann, T. O., & Hartwigsen, G. (2021) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_01591 · Cited by 264
Rehabilitating the addicted brain with transcranial magnetic stimulation
Diana, M., Raij, T., Melis, M., Nummenmaa, A., Leggio, L., & Bonci, A. (2017) · Nature Reviews Neuroscience · doi:10.1038/nrn.2017.113 · Cited by 218
Vucic, S., Stanley Chen, K.-H., Kiernan, M. C., Hallett, M., Benninger, D. H., Di Lazzaro, V., Rossini, P. M., Benussi, A., Berardelli, A., Currà, A., et al. (2023) · Clinical Neurophysiology · doi:10.1016/j.clinph.2023.03.010 · Cited by 212
Neural effects of transcranial magnetic stimulation at the single-cell level
Romero, M. C., Davare, M., Armendariz, M., & Janssen, P. (2019) · Nature Communications · doi:10.1038/s41467-019-10638-7 · Cited by 202
Farzan, F., Vernet, M., Shafi, M. M. D., Rotenberg, A., Daskalakis, Z. J., & Pascual-Leone, A. (2016) · Frontiers in Neural Circuits · doi:10.3389/fncir.2016.00073 · Cited by 173
“As discussed in Section Controlling for TMS Click, a thin layer of foammay be placed between the EEG electrodes and the TMS coil to minimize AEP (auditory-evoked potentials) due to bone conduction of TMS click.”
BackgroundMethodMethods for analysis of brain connectivity: An IFCN-sponsored review
Rossini, P. M., Di Iorio, R., Bentivoglio, M., Bertini, G., Ferreri, F., Gerloff, C., Ilmoniemi, R. J., Miraglia, F., Nitsche, M. A., Pestilli, F., et al. (2019) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.06.006 · Cited by 162
“TMS-evoked EEG potentials (TEPs) occurring in the first 20–40 ms after the TMS pulse most likely reflect the responses of cortical circuits excited underneath the stimulator (Mueller et al., 2014; Li et al., 2017).”
BackgroundBungert, A., Antunes, A., Espenhahn, S., & Thielscher, A. (2016) · Cerebral Cortex · doi:10.1093/cercor/bhw292 · Cited by 160
Hanlon, C. A., Dowdle, L. T., Correia, B., Mithoefer, O., Kearney-Ramos, T., Lench, D., Griffin, M., Anton, R. F., & George, M. S. (2017) · Drug and Alcohol Dependence · doi:10.1016/j.drugalcdep.2017.03.039 · Cited by 125
“…(intermittent theta burst stimulation; iTBS) to the cortex, it is possible to induce an LTP-like effect on both behavior and neural activity (as measured through neuroimaging (Cho and Strafella, 2009; Siebner et al., 2009), as well as electrophysiological recordings (Mueller et al., 2014)).”
BackgroundMonitoring demands for executive control: shared functions between human and nonhuman primates
Mansouri, F. A., Egner, T., & Buckley, M. J. (2017) · Trends in Neurosciences · doi:10.1016/j.tins.2016.11.001 · Cited by 89
“Another promising new approach to assessing cross-species functional homology comprises the adoption of equivalent neural measurement and perturbation techniques (such as transcranial magnetic stimulation) across species [62].”
Self-citation
Metadata
- Authors
- Mueller, J. K., Grigsby, E. M., Prevosto, V., Petraglia, F. W., Rao, H., Deng, Z.-D., Peterchev, A. V., Sommer, M. A., Egner, T., Platt, M. L., & Grill, W. M.
- Venue
- Nature Neuroscience
- Published
- 2014-06-29
- Volume
- 17
- Issue
- 8
- Pages
- 1130-1136
- ISSN
- 1097-6256 (ISSN-L)
- 1546-1726
- OpenAlex
- W2146803302
- Cited by
- 151
- References
- 5
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.