The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Digitally synthesized beat frequency multiplexing for sub-millisecond fluorescence microscopy
Open accessAbstract
Fluorescence imaging is the most widely used method for unveiling the molecular composition of biological specimens. However, the weak optical emission of fluorescent probes and the trade-off between imaging speed and sensitivity1 are problematic for acquiring blur-free images of fast phenomena, such as sub-millisecond biochemical dynamics in live cells and tissues2, and cells flowing at high speed3. Here, we report a technique that achieves real-time pixel readout rates that are one order of magnitude faster than a modern electron multiplier charge-coupled device—the gold standard in high-speed fluorescence imaging technology4. Termed fluorescence imaging using radiofrequency-tagged emission (FIRE), this approach maps the image into the radiofrequency spectrum using the beating of digitally synthesized optical fields. We demonstrate diffraction-limited confocal fluorescence imaging of stationary cells at a frame rate of 4.4 kHz, and fluorescence microscopy in flow at a velocity of 1 m s−1, corresponding to a throughput of approximately 50,000 cells per second. A confocal fluorescence microscopy scheme that maps the image to the radiofrequency spectrum by beating together two optical fields offers enhanced read-out speeds at kilohertz frame rates. It provides a new way for observing dynamic phenomena in cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Allard, W. J., Matera, J., Miller, M. C., Repollet, M., Connelly, M. C., Rao, C., Tibbe, A. G. J., Uhr, J. W., & Terstappen, L. W. M. M. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-0378 · Cited by 2,542
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Cited by
High-speed fluorescence image–enabled cell sorting
Schraivogel, D., Kuhn, T. M., Rauscher, B., Rodríguez-Martínez, M., Paulsen, M., Owsley, K., Middlebrook, A., Tischer, C., Ramasz, B., Ordoñez-Rueda, D., et al. (2022) · Science · doi:10.1126/science.abj3013 · Cited by 284
Self-citationOta, S., Horisaki, R., Kawamura, Y., Ugawa, M., Sato, I., Hashimoto, K., Kamesawa, R., Setoyama, K., Yamaguchi, S., Fujiu, K., et al. (2018) · Science · doi:10.1126/science.aan0096 · Cited by 257
Metadata
- Authors
- Diebold, E. D., Buckley, B. W., Gossett, D. R., & Jalali, B.
- Venue
- Nature Photonics
- Published
- 2013-09-22
- Volume
- 7
- Issue
- 10
- Pages
- 806-810
- ISSN
- 1749-4885 (ISSN-L)
- 1749-4893
- OpenAlex
- W2102177695
- Cited by
- 175
- References
- 2
- FWCI
- 5.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Digitally synthesized beat frequency multiplexing for sub-millisecond fluorescence microscopy. https://app.cochat.ai/papers/10.1038/nphoton.2013.245
- The paper
- Diebold, E. D., Buckley, B. W., Gossett, D. R., & Jalali, B. (2013). Digitally synthesized beat frequency multiplexing for sub-millisecond fluorescence microscopy. Nature Photonics. https://doi.org/10.1038/nphoton.2013.245
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.