Subwavelength coherent imaging of periodic samples using a 13.5 nm tabletop high-harmonic light source
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Coherent diffractive imaging is unique, being the only route for achieving high spatial resolution in the extreme ultraviolet and X-ray regions, limited only by the wavelength of the light. Recently, advances in coherent short-wavelength light sources, coupled with progress in algorithm development, have significantly enhanced the power of X-ray imaging. However, so far, high-fidelity diffraction imaging of periodic objects has been a challenge because the scattered light is concentrated in isolated peaks. Here, we use tabletop 13.5 nm high-harmonic beams to make two significant advances. First, we demonstrate high-quality imaging of an extended, nearly periodic sample for the first time. Second, we achieve subwavelength spatial resolution (12.6 nm) imaging at short wavelengths, also for the first time. The key to both advances is a novel technique called ‘modulus enforced probe’, which enables robust and quantitative reconstructions of periodic objects. This work is important for imaging next-generation nano-engineered devices. Coherent diffractive imaging of periodic samples is demonstrated with a tabletop, 13.5 nm high-harmonic source. With a novel image reconstruction technique, the record high spatial resolution of 12.6 nm is achieved in the extreme-ultraviolet region.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Henke, B. L., Gullikson, E. M., & Davis, J. C. (1993) · Atomic Data and Nuclear Data Tables · doi:10.1006/adnd.1993.1013 · Cited by 6,285
Phase retrieval algorithms: a comparison
Fienup, J. R. (1982) · Applied Optics · doi:10.1364/ao.21.002758 · Cited by 5,596
Miao, J., Charalambous, P., Kirz, J., & Sayre, D. (1999) · Nature · doi:10.1038/22498 · Cited by 1,976 · cited 3×
“Initial implementations of CDI used mostly pinhole-like test samples that permitted the use of an isolation constraint on the object itself, facilitating phase retrieval 17,28 .”
BackgroundMethodReconstruction of an object from the modulus of its Fourier transform
Fienup, J. R. (1978) · Optics Letters · doi:10.1364/ol.3.000027 · Cited by 1,836 · cited 2×
“This additional constraint to the probe is analogous to the error-reduction algorithm as described in by Fienup 20 , but instead of using error-reduction to solve for the object, it is used within the ptychography algorithm to further constrain the probe guess.”
MethodA compact X-ray free-electron laser emitting in the sub-ångström region
Ishikawa, T., Aoyagi, H., Asaka, T., Asano, Y., Azumi, N., Bizen, T., Ego, H., Fukami, K., Fukui, T., Furukawa, Y., et al. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.141 · Cited by 1,819
An improved ptychographical phase retrieval algorithm for diffractive imaging
Maiden, A. M., & Rodenburg, J. M. (2009) · Ultramicroscopy · doi:10.1016/j.ultramic.2009.05.012 · Cited by 1,496 · cited 5×
“Reconstructed intensity images of the zone plate sample, obtained with the ePIE ptychography algorithm 34 with and without the novel MEP constraint, are displayed in Fig.”
BackgroundMethodInfluentialHigh-Resolution Scanning X-ray Diffraction Microscopy
Thibault, P., Dierolf, M., Menzel, A., Bunk, O., David, C., & Pfeiffer, F. (2008) · Science · doi:10.1126/science.1158573 · Cited by 1,321 · cited 3×
“The novel probe constraint, which utilizes the measured probe intensity on the detector, ℙ ( 𝒖 ) , where u is the spatial frequency coordinate vector on the detector plane, can be implemented in many phase-diverse CDI techniques 31,32,34,42 .”
BackgroundMethodPhase Retrieval with Application to Optical Imaging: A contemporary overview
Shechtman, Y., Eldar, Y. C., Cohen, O., Chapman, H. N., Miao, J., & Segev, M. (2015) · IEEE Signal Processing Magazine · doi:10.1109/msp.2014.2352673 · Cited by 1,131
Ptychographic X-ray computed tomography at the nanoscale
Dierolf, M., Menzel, A., Thibault, P., Schneider, P., Kewish, C. M., Wepf, R., Bunk, O., & Pfeiffer, F. (2010) · Nature · doi:10.1038/nature09419 · Cited by 926
Phase-Matched Generation of Coherent Soft X-rays
Rundquist, A., Durfee, C. G., Chang, Z., Herne, C., Backus, S., Murnane, M. M., & Kapteyn, H. C. (1998) · Science · doi:10.1126/science.280.5368.1412 · Cited by 907 · cited 4×
“Recent advances in coherent short wavelength light sources, including tabletop high-harmonic generation 4–6 as well as large-scale synchrotron and free electron laser facilities 7 , combined with coherent imaging methods, leads to unique new imaging capabilities 8–15 .”
BackgroundMethodInfluentialSelf-citation
Cited by
Roadmap of ultrafast x-ray atomic and molecular physics
Young, L., Ueda, K., Gühr, M., Bucksbaum, P. H., Simon, M., Mukamel, S., Rohringer, N., Prince, K. C., Masciovecchio, C., Meyer, M., et al. (2018) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/1361-6455/aa9735 · Cited by 337
Self-citation
Metadata
- Authors
- Gardner, D. F., Tanksalvala, M., Shanblatt, E. R., Zhang, X., Galloway, B. R., Porter, C. L., Karl Jr, R., Bevis, C., Adams, D. E., Kapteyn, H. C., Murnane, M. M., & Mancini, G. F.
- Venue
- Nature Photonics
- Published
- 2017-03-20
- Volume
- 11
- Issue
- 4
- Pages
- 259-263
- ISSN
- 1749-4885 (ISSN-L)
- 1749-4893
- OpenAlex
- W2597958772
- Cited by
- 243
- References
- 34
- FWCI
- 26.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Subwavelength coherent imaging of periodic samples using a 13.5 nm tabletop high-harmonic light source. https://app.cochat.ai/papers/10.1038/nphoton.2017.33
- The paper
- Gardner, D. F., Tanksalvala, M., Shanblatt, E. R., Zhang, X., Galloway, B. R., Porter, C. L., Karl Jr, R., Bevis, C., Adams, D. E., Kapteyn, H. C., Murnane, M. M., & Mancini, G. F. (2017). Subwavelength coherent imaging of periodic samples using a 13.5 nm tabletop high-harmonic light source. Nature Photonics. https://doi.org/10.1038/nphoton.2017.33
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.